Display Calibrators
reference a test pattern to adjust by.
-
product
Calibration Light Source
CAL1
Image Engineering GmbH & Co. KG
The one light source solution in the field of camera characterization and calibration. CAL1The CAL1 calibration light source is designed to characterize and calibrate cameras in the lab or on the production line. Its compact design consists of one iQ-LED element in a 0.3 m integrating sphere that illuminates a 70 mm opening. Because of the non-reflective special diffusor filter on the sphere opening, a uniformity of more than 98% could be reached
-
product
Remote & Large Digit Displays
Remote and Large Digit Displays, as defined in this web page, are numeric displays that are driven by a serial signal from a computer, programmable controller, or other instrument. Digit heights can range from 0.56" (14.2 mm) to 11.0" (280 mm). Laureate remote displays, with a digit height of 0.56", are similar to a digital panel meter or counter in appearance.
-
product
Temperature and Relative Humidity Mini Data Logger with Display
HD206/226/207/227
Minidatalogger Temperature - Temperature/Relative Humidity. Monitoring, reliable over time, working range -30...+80 °C instrument, -40...+105 °C probe with cable.
-
product
Calibration
EMC Test Antennas
There are some changes in the calibration standard ANSI C63.4 concerning the calibration procedures of hybrid antennas, also the newly issued standard - CISPR 16-1-6 dealing with EMC antenna calibration is covered by our services. You are very welcome to consult Seibersdorf Laboratories calibration experts for the recommended calibration procedures of the most common radiated emission test standards.
-
product
Mercury Argon Calibration Source
HG-1
The compact, low-cost HG-1 Mercury Argon Calibration Source is a spectral wavelength calibration source for UV-VIS-Shortwave NIR spectrophotometric systems.
-
product
ATE / Bench Calibrators & Multimeters
Time Electronics offer a range of precision calibrators and digital multimeters that can be used in the lab or in automated testing applications. These programmable instruments are designed for precision, performance, and functionality, making them ideal for automatic testing and fault diagnosis. Each designated ATE calibrator is rack mountable for straightforward integration into user systems.
-
product
Precision Calibrated Noise Sources
ELVA-1's calibrated noise source ISSN-XX series delivers a uniform level of noise power spectral density within the whole waveguide frequency range. Sources are available in eight waveguide bands covering 26.4-170 GHz.
-
product
Calibration Kit
FMCK1000
Designed to withstand daily use in high-traffic environments such as in the testing lab or on the production floor. This cost effective calibration kit provides reliable and accurate instrument tuning for all of your test and measurement requirements. Applications: VNA, Full 2-Port CAL VNA, Thru CAL VNA, Substitution CAL method Test & Measurement Lab Equipment Accessories Engineering Test and Evaluation General Purpose Test and evaluation.
-
product
Photometric Ozone Calibrator
Model T703
Teledyne Advanced Pollution Instrumentation
The Model T703 is a microprocessor controlled ozone calibrator for precision gas analyzers. The Model T703 can deliver concentrations from 50 ppb to 5 ppm at flows from 1 LPM to 5 LPM.The Model T703 has two major components; the ozone generating device and the photometer. The ozone generator produces ozone by passing zero air over a UV lamp. Flow rate and lamp intensity are adjusted to deliver a specified ozone concentration by volume. The temperate and pressure compensated photometer, identical to that of the Model T400 ozone analyzer, provides feedback control of the UV lamp intensity, assuring stable ozone output. A nearly unlimited number of calibration sequences may be programmed into the non-volatile memory of the T703, covering time periods up to a year.
-
product
Medical Grade All-in-One Panel Computer with 13.3”/15.6” Full HD Display
MLC-AL/ MLC-KL
The MLC-AL/MLC-KL Series of medical panel computers feature a fully sealed aluminum housing for easy cleaning. As a result of its hygienic surface design that eliminates exposed screw heads and air vents, the MLC-AL/MLC-KL Series can be easily and quickly cleaned using all common disinfectants and cleaning agents.The MLC-AL/MLC-KL comes in two display sizes, 13.3” and 15.6”, which are ideal for ICUs, emergency rooms and the hospital wards. In addition to the standard galvanically isolated network connections, the MLC-AL/MLC-KL can be optionally equipped with galvanically isolated USB and serial interfaces for connection to external non-medical devices. Compliant with 2x MOPP, the MLC-AL/MLC-KL meets the comprehensive requirements of the IEC/EN-60601-1 (Edition 3.1) and IEC/EN-60601-1-2 (4th Edition) standards.
-
product
Partial Discharge Calibrator
TPK-H
The high voltage-resistant Partial Discharge calibrator is used to determine the correction factor in the PD test circui.
-
product
Automatic Calibration Module
ACM4520
ACM4520 is an automatic calibration module that can be used with all CMT Vector Network Analyzers operating in frequency range up to 20 GHz. It is a fully automatic USB-controlled and powered electronic calibration module. Minimizing the number of steps required by technicians reduces the risk of human error and expedites the calibration process.
-
product
VME Display And Bus Analyzer Module
VM-DBA
VM-DBA is a new test and diagnostic module for VME-bus systems which visualizes activities on all VME bus lines on the set of front-panel LEDs, but also allows one to digitize individual waveforms of all these lines into 2kBit -long storage memories, for a subsequent readout via VME or USB interfaces.
-
product
UV/VIS/NIR Spectrophotometer Calibration Standards
As the world's foremost spectrophotometer reference standard manufacturer, we have a dedicated staff and years of experience to back up our products. Our solid state UV/VIS/NIR reference standards are the most stable on the market and remain in spec long after many other manufacturer's standards go bad. Relying on our proprietary nano-deposition technology, you can rest assured that our solid-state standards will produce steady readings for years to come on your machines.
-
product
Spectral Irradiance / Illuminance Calibration Standards
Standard lamps calibrated in illuminance and spectral irradiance. Traceable calibrations in the wavelength range from 200 nm to 2500 nm.
-
product
Temperature Calibration System
Thermal Engineering Associates, Inc.
Systems for determining relationship between temperature-sensing junction voltage versus junction temperature of diodes, integrated circuits and thermal test die. Provides internal current sources, voltage measurement to 1 mV, and temperature measurement to 0.1ºC. 16-channel capability with optional printer and serial port data output.
-
product
Digital Tap Position Indicator With Voltage &Counter Display
NMC''s latest offering digital tap position indicator with voltage and counter display, type: TX-204, is a fully micro controller based instrument used to indicate the tap position of the power transformer also indicating the voltage and counter indications simultaneously at a same time.
-
product
Temperature & Process Calibrators
The most sophisticated industrial equipment will not be useful unless it is calibrated. GAOTek Process Calibrators are used to adjust instruments’ accuracy, and they are the only process calibrator you will ever need to carry. They can measure temperature, pressure, voltage, resistance and frequency, and can be used during troubleshooting. Through calibration, you can ensure that any equipment performs as expected and that it can be relied on to deliver predictable and accurate results that meet quality standards. GAOTek Process Calibrators come with a USB interface which makes it easier to transfer the results to other devices which otherwise would have taken a long time to transcribe them. Our Process Calibrators are for sale to the United States, Canada and globally.
-
product
Relative Humidity Calibration Services
PST have calibration laboratories offering Relative Humidity calibrations in six locations across the globe.
-
product
Digital Display Auto Circuit Tester
1676
Peaceful Thriving Enterprise Co Ltd
This is a DC voltage tester with smart over-voltage protection and warning for vehicle repair. As electrical system for vehicle becomes more complex, the tester is able to test voltage value, identify DC polarity from different background light color, positive / negative sign, and over-voltage level indication. Moreover, the special designed probe is able to help user to hook, piercing, and probing the wires.
-
product
Remote Displays
HS Series
Load cell / scale remote displays are driven from another digital indicator or amplifier. Often used on bridge cranes and truck scales, or in any situation which the person needing to see the scales displayed weight is too far to see the smaller standard indicators. Many styles, digit sizes, indoor and outdoor models are available.
-
product
Pressure Calibrator
HPC40
AMETEK Sensors, Test & Calibration
The HPC40 Series handheld pressure calibrator is the world's first combined pressure and mA loop calibrator to be fully temperature compensated from -20 to 50°C. You can count on the same accuracy whether measuring pressure, current, voltage, or temperature.
-
product
Display
Seismograph
Seismograph program is used for continuous data representation by a large amount of channels (simultaneously and in identical scale – for the purpose of timely detection of the events occurring in the system).
-
product
Insulation & Multifunction Tester (LCD Display)
1153 AI
Standard Electric Works Co., Ltd
● Microprocessor-controlled.● Automatic voltmeter AC/DC at Start/Reset.● Auto range● Auto off.● Battery test.● Battery test at switch ON/Reset.● Safety voltmeter before each test.● Auto discharge on all test and all ranges.● Leads Auto-Null key.● Test Auto-Stop.● Smart hold & stop on voltmeter ac/dc.● Ener-Save feature to extend battery life.● Continuity short circuit current > 220mA.● Continuity open circuit voltage of 5Vdc.● Nominal voltage @ 1mA on all insulation ranges.● Accept 8 rechargeable batteries or Alkaline of normal.● BS 16 edition.
-
product
Blackbody Calibrators
Omega offers a diverse portfolio of blackbody calibrators used to calibrate infrared pyrometers. Blackbody calibrators use a high emissivity target plate or target cavity to minimize error.
-
product
Insulation Tester Calibrator
DecR
SCOPE offers High Resistance, High Voltage Decade Resistance Box - DecR. It contains number of smartly configured precision resistors. They are arranged in such a way that user can obtain desired resistance value by selecting appropriate decade switches. DecR is designed using the high quality specially selected resistors. These range of high ohm resistance decades are ideal for variety of applications, having a voltage rating up to 5 kV. It covers the resistance range from 1 kilo ohm to 1 tera ohm. DecR can also be customized as per requirement. DecR is housed in a rugged case and available in 3 / 4 / 6 / 9 decades or in binding post configuration
-
product
Fixture Self-Test Controller and Calibration Check
AQ818
The module AQ818 includes all the electronic blocks required to perform an effective test platform self-test. Thanks to this module, a chain of tests can be performed, which will end up not only with a report of the defective instruments or switch modules, but also with the relay contacts live expectancy report.
-
product
Calibration Sources
Accurately verify the output signals of your pyrometers, thermal imaging systems, heat-flux measurement systems, or spectrographic analysis systems. We offer unique and very precise Mikron® calibration sources. Our blackbodies feature cutting-edge emissivity values, homogenous emission areas, and various different-sized apertures. And fast heat-up times and high temperature stability are guaranteed.
-
product
RTC Reference Temperature Calibrator
AMETEK Sensors, Test & Calibration
Our most advanced and accurate portable temperature calibrator with the widest available temperature range. One of its great features is the patented DLC system for perfect temperature uniformity in the insert – even when calibrating large sensors or many sensors at a time.





























