Solenoid
Act as a magnet when current flows through moving an iron core.
-
Product
Single 4x4 1-Pole 16 Amp PXI Power Matrix With Loop-Thru
40-552-011
Matrix Switch Module
The 40-552 range of 16 Amp PXI power matrix modules is available in four configurations with matrix sizes of 8x2 and 4x4 and the ability to expand the matrix size with the Y-Axis loop-thru connections: e.g. 8x4, 12x4, 16x4, etc. (with 4x4 matrices) or 16x2, 24x2, 32x2, etc. (with 8x2 matrices). This range is capable of switching up to 16 Amps and up to 300VDC/250VAC hot switching and 400VDC/250VAC cold switching. These PXI power matrix modules are intended for switching heavy AC or DC loads or for the slave switching of large external relays, contactors, and solenoids.
-
Product
PXI 5A Power MUX, 8-Bank, 5-Channel
40-651-004
Multiplexer Module
This range of high density power multiplexer modules is suitable for switching inductive/capacitive loads up to 5A at 250VAC. It is available in the following 1-pole multiplexer formats: 1-bank 48-channel. 2-bank 24-channel. 4-bank 11-channel. 8-bank 5-channel. Connections are made via a front panel 50-way male D-type connector. Power multiplexer modules are intended for switching heavy AC or DC loads or for slaving up to large external relays, contactors and solenoids.
-
Product
Stationary Decoders
-
The DS64 Stationary Decoder allows you to install and operate your turnouts directly through any DCC system that has turnout control. The DS64 works with a wide selection of hardware. From solenoid turnout machines to slow motion motors, the DS64 hasn’t met a turnout it doesn’t like. This affordable, easy to install decoder will add another dimension to your operations.
-
Product
Engine Speed Control and Measurement (Test Set A)
MS 1100
-
*Checks the parameters such as current, voltage, speed, and turbine gas temperature of 804E and 811 engines Portable instrument*Testing of Automatic engine control system and after burner control system*Simulates the temperature signal derived from the engine TGT (Temperature Gas Turbine) thermocouples*Simulates the speed signal, NL (low pressure shaft speed signal) drive from the L.P shaft Probe*Indicates the current signal to the FCU solenoid derived from the engine control amplifier*Measure the TGT and NL simulated signal at static position*Measure the signal produced by the engine TGT thermocouples*Measure the NL signal produced by the LP shaft*Measure the NH (High-pressure shaft speed) signal produced by HP shaft*Indicates the solenoid current, produced by the engine control amplifier*Indicates the solenoid voltage, produced by the engine control amplifier*Used to test engine in both static and dynamic states
-
Product
PXI General Purpose 2A Relay Module 16xSPDT, 50 D-sub
40-131-001
Relay
These low cost, general purpose electromechanical relay cards are capable of switching voltages up to 300VDC/250VAC and current up to 2A. They are suitable for use where reed relay based switching cards do not have sufficient voltage or current carrying capability. Applications include the switching of medium power AC and DC loads, or slave switching larger relays, contactors or solenoids. Connections are made to the card via a front panel mounted 50 pin D-Type connector plug.
-
Product
PXI 8x4 1-Pole 10A Matrix With Loop-Thru
40-551-101
Matrix Switch Module
Used for switching inductive/capacitive loads up to 10A with 125VDC/250VAC hot switching and 400VDC/250VAC cold switching. X and Y connections are made via a 20-way GMCT plug, this module with loop-thru has an additional 20-way GMCT plug for module-to-module connection. This version of the 40-551 may be expanded to larger matrix sizes using cabling to daisy-chain the X and Y signals Power Matrix Modules are intended for switching heavy AC or DC loads or for slaving large external relays, contactors and solenoids. Suitable for applications requiring switching of either mains voltage or direct current.
-
Product
Carbon Dioxide Quality Control System
CDQC
-
Teledyne Analytical Instruments
Teledyne’s Carbon Dioxide Quality Control (CDQC) system offers an integrated package to continuously monitor impurities in carbon dioxide (CO2). The plug-and-play design allows for the user to select only the gases and features of interest to maximize cost benefit and space.Front door viewing windows allow for view of all analyzer displays, flow and pressure settings. Stainless steel tube fitting connections and NPT or metric electrical ports as required are conveniently located in a central location for ease of access. Sample conditioning, utility gas provisions and integral calibration gas solenoid valves are standard.
-
Product
PXI 12xSPDT 16A Power EMR Module
40-161-101
Relay
This40-161 range of PXI power relay modules is available with achoice of 16 x SPST, 12 x SPST, 10 x SPST, 12 x SPDT and 6 x SPDT power relays, for switching loads up to 16A at250VAC. These Power Relay Modules are intended for switching heavy AC or DC loads or for the slave switching of large external relays, contactors and solenoids. The 40-161 is ideal for switching up to 16A in both AC and DC applications.
-
Product
Walk / Drivable test facilities
TW / CW series
-
Walk or drive-in temperature and climatic test chambers can be designed from CTS by a standardized grid system affordable in all sizes. The refrigeration performance data are adjusted here by our experienced sales and project engineers on your testing out. The walk / drive-chambers are ideal for larger components and finished products. CTS as a medium sized company attaches great importance to the detail quality of the equipment components, with only the best supplier products such as compressor and solenoid valves are used. Your resulting advantages are trouble-free long-term operation and thus no loss of valuable test time.
-
Product
Engine Simulator
MS 1118
-
Test Set-A calibration unit is a test jig is used to simulate parameters of Adour 804E and 811 engines of Jaguar aircrafts. It simulates current, voltage, speed, and turbine gas temperature. It performs NL Check, NH Check, TGT1 (Non T2 Compensated), TGT2 (T2 Compensated), Amp (Non T2 Compensated), Amp (T2 Compensated), Solenoid Volt, TGT Inject, NL Inject, and NL/TGT Redatum.
-
Product
PXI 8x4 Power Matrix, 2 Pole
40-550-002
Matrix Switch Module
Connections are made via a front panel 37-way D-Type male connector or two 20-way GMCT male connectors. Used for switching inductive/capacitive loads up to 5A at 250VAC. Power matrix modules are intended for switching heavy AC or DC loads or for slaving up to large external relays, contactors and solenoids. Used for applications requiring switching of either mains voltage or direct current. These modules are fitted with electro-mechanical power relays, gold-flash over silver alloy. A spare relay is built onto the circuit board to facilitate easy maintenance with minimum downtime.
-
Product
Vapor Source Mass Flow Controller With Viscous Laminar Flow
-
The 1152C Vapor Source Mass Flow Controller is a pressure-based measurement and control system designed to meter and control vapor from low vapor pressure liquid and solid sources directly, without the need of a carrier gas. The 1152C consists of a fixed flow element and two capacitance manometers for flow measurement, with a proportioning solenoid control valve for flow control.
-
Product
High-Power PXI Switch Matrix Modules
-
These high-power PXI switch matrix modules provide higher current and power ratings than the high-density switch versions. These modules are designed for the switching of AC or DC loads or for controlling large relay or solenoid systems. The solid state relay matrices occupy two PXI slots and are suitable for automotive and aerospace test applications.
-
Product
PXI General Purpose 2A Relay Module 16xSPDT, 78 D-sub
40-131-101
Relay
Low cost, general purpose electromechanical relay cards suitable for use where reed relay based switching cards do not have sufficient voltage or current carrying capability. Applications include switching of medium power AC and DC loads or slave switching larger relays, contactors or solenoids. Connections are made to the card via a front panel mounted 50 or 78 pin D-Type connector plug.
-
Product
64-Channel 500kSa/s USB Modular Multifunction Data Acquisition
U2356A
Data Acquisition Module
The U2356A offers multifunction capabilities in a module. It can be used like a digital multimeter in polling mode. It can be transformed to be a simple scope using the continuous mode with simple triggering capabilities. No matter if it is used as a standalone module or when plugged into a U2781A USB modular instrument chassis, the synchronization and triggering capabilities allow great flexibility in making the desired measurements. With the analog output being able to send out predefined or arbitrary waveforms make this a good tool when closed loop feedback or stimulus is required. The digital IO channels allows for closed loop control through connections to switches, relays and solenoids. The burst mode enables the U2356A to simulate simultaneous analog input acquisition.
-
Product
PXI H. Density Digital I/O Module 32 Bit O/C
40-410-002
Digital I/O
The 40-410 range of Digital I/O Modules are suitable for operating external devices, such as heavy duty relays (power, RF and high voltage types), solenoids, lamps, or for interfacing with external logic such as a programmable instrument with a BCD interface. Two choices of output drive are available: TTL for interacting with external logic and Open Collector Transistor for operating external devices with voltages to 50VDC and currents to 500mA.
-
Product
PXI SPDT Switch: 26-ch, 2A, Armature Relay
M9130A
Switch Module
The M9130A is a general purpose switch with 26 independent, single-pole, double-throw (Form C) switches in a single PXI module. This module can be used to cycle power to products under test, control indicator and status lights or actuate external power relays and solenoids. The armature relays can handle up to 60W power. When needed, these relays can handle up to 6A pulsed carry current. Choose from the durable connector block or standard cable connections.