I²C
A slow Inter-Integrated Circuit bus protocol.
-
product
NI-9221, ±60 V, 800 kS/s, 12-Bit, 8-Channel C Series Voltage Input Module
779014-01
±60 V, 800 kS/s, 12-Bit, 8-Channel C Series Voltage Input Module - The NI‑9221 performs single-ended analog input. The wider voltage range makes this module well suited for industrial-level, automotive, or even smaller-cell battery measurements. There are two connector options for the NI‑9221: a 36‑position spring‑terminal connector and a 37-position D‑SUB connector.
-
product
Pico-ITX SBC With 7th Gen Intel® Core™ I7/i5/i3 & Celeron® Processor, HDMI/LVDS And LAN
PICO512
The PICO512 is designed to support the latest 7th generation Intel® Core™ processor or Celeron® processor 3965U. Coming with one 260-pin DDR4-2133 SO-DIMM socket supporting system memory up to 16 GB, the Pico-ITX motherboard also features a PCI Express Mini Card slot in support of mSATA and a pair of expansion connectors for an additional I/O board/signals. It supports a 4K visual experience with dual display outputs through HDMI and LVDS. Pico-ITX SBC can withstand a wide operating temperature range from -20°C to +70°C.
-
product
85W to 120W - Single Output
HQA Series
*Standard Quarter Brick Footprint*9-40 Vdc, 18-40 Vdc Inputs*3.3, 5, 12, 15, 24, 28, 48 Vdc Outputs*2250 Vdc Isolation*-55 to 115°C Baseplate temperature*MIL-STD-461; 1275; 704; DO-160*No Optocouplers used
-
product
Manual Step Attenuator, DC to 18 GHz, 0 to 110 dB, 10 dB steps
8496B
The Keysight 8496B dc to 18 GHz manual step attenuator offers exceptional repeatability and reliability. Attenuation is provided in 10 dB steps from 0 to 110 dB. Precision gold-plated leaf springs ensure long life (over 5 million cycles) and very high attenuator repeatability (typically 0.01 dB). To improve measurement accuracy, NIST traceable data (SWR and attenuation) is available as Option UK6. Custom step attenuator/switch combinations are possible. The Keysight 11716A/B/C interconnect kits provide quick connection of Keysight 8494/5/6/7 1 dB and 10 dB step attenuators in series for greater dynamic range with 1 dB steps.
-
product
Micro Coax, Contact, Receiver, 50 GHz
610140108
Primary mating contact 610141108. (May mate with other ITA contacts, as well.) *This contact sold as a patchcord only.Mechanical SpecificationsDurability 10,000 cyclesContact Material Center Conductor – BeCuShield – BrassContact Plating 30µ" Au over 100µ" NiContact Termination Solder Nut ClampInsulator PTFEMating Force 1.5 lbs max [0.68 kg]Electrical SpecificationsCharacteristic Impedance 50 ΩFrequency Range DC-50GHzVSWR 1.06+0.004 f(GHz)Insertion Loss - .095 x √f(GHz) dBDWV 700 V RMSContact Resistance 6 mOhms center/4 mOhms outer Cable Specifications Flex 405Environmental SpecificationsOperating Temperature -65°C to +125°CVibration MIL-STD 202, Method 204, Test Condition DShock MIL-STD 202, Method 213, Test Condition IInsulation Resistance 2000 MOhms Min.
-
product
Medical Leakage Current Tester
2675Y
Shenzhen Chuangxin Instruments Co., Ltd.
The 2675Y Medical Leakage Current Tester Series Is The Test Equipment Used For Measuring Continuous Leakage Current And Patient Auxiliary Current Of Medical Electrical Equipment.It Designs And Products According To The GB9706.1_2020 (IEC60601-1:2012) .And The Test Circuit (MD)Input Impedance To Simulate The Body Impedance,It Accord With The Requirements Of GB9706.1-2020 (IEC60601-1:2012),The Test Current Can Run Up To 5A,And Provide Users With An Isolation Power Supply Which Adjustable Output Voltage For 0~250V Continuously Of The Basic Capacity Configuration For The 500VA And Provide Another 110% Voltage Source Of The Maximum Rated Voltage.It Can Satisfy The I,II, Various Types Of Equipment Test The Earth Leakage Current,Shell Leakage Current,Patient Leakage Current,Patient Auxiliary Leakage Current Under Normal Condition And The Single Fault.
-
product
ARINC 429 Test And Simulation PMC Module
PMC-429
*4, 8, 16 or 32 software programmable TX / RX channels*Programmable high / low speed operation*Simultaneous operation of all TX / RX channels*PXI interrupts, star trigger, and PXI clock*Error entry and detection*128 MB RAM*Label selective triggering for recording / filtering*IRIG-B timecode encoder / decoder for data correlation*Real-time recording and later analysis of multiple channels*Sorting according to SDI field*VXI Plug & Play driver including soft front panel*Supports: C, C ++, C # and .net*Driver support: Windows, Linux, VxWorks and other systems
-
product
FieldFox C Handheld RF Analyzer, 4 GHz
N9913C
Capture elusive signals with up to 120 MHz gap-free, real-time bandwidth. Measure all four S-parameters simultaneously with 115 dB dynamic range. Make accurate spectrum analyzer measurements (± 0.3 dB) without warmup. Perform over-the-air measurements for 5G NR and LTE. Use GPS/GNSS for geolocation and timestamping.
-
product
NI-9208, 500 S/s, ±20 mA, 16-Channel C Series Current Input Module
785041-01
500 S/s, ±20 mA, 16-Channel C Series Current Input Module - The NI‑9208 is designed with industrial systems in mind. It includes a high-resolution mode with 50/60 Hz rejection to remove low frequency noise. It has high-channel density to reduce the number of modules needed, which leaves slots open for other measurement types or for reducing the overall per channel cost of the system. The NI‑9208 uses a standard D‑SUB connection for use with cables and connector blocks.
-
product
64 Output USB Modular Digital I/O
U2653A
The Keysight U2653A USB Digital I/O is a cost-effective device with its offering of 64 opto-isolated digital lines. It comes bundled with the Keysight Measurement Manager (AMM) software for quick set up and data logging. Simplifying this further is the command logger function offered in the Keysight Measurement Manager that allows capturing of configuration commands that can be easily converted to snippets of VEE code. Other supported languages are VB, C++, and C#.
-
product
Voltage Input Device For FieldDAQ
The Voltage Input Device for FieldDAQ measures up to eight ±10 V channels with 24-bit resolution and simultaneous sample rates up to 100 kS/s/ch. Some models can power sensors, such as pressure sensors, with up to 24 V per input channel. This device offers 500 V channel-to-channel isolation, protecting instrumentation from high-transient voltages. Additionally, the device is IP65 and IP67 rated to be dust-proof and water-submersible, can operate in -40 °C to 85 °C environments, and can sustain 100 g shock and 10 g vibration. It has an integrated network switch for simplified daisy chaining and provides tight synchronization over time sensitive networking (TSN) for distributed data acquisition systems.The Voltage Input Device for FieldDAQ includes the NI-DAQmx driver and configuration utility that simplify configuration and measurements. NI-DAQmx supports NI programming environments as well as Python, ANSI C, C#.NET, and MathWorks MATLAB® software.
-
product
2.5 GHz, 0.9 pF, 1 MOhm Active Voltage Probe
ZS2500
Engineers must commonly probe high frequency signals with high signal fidelity. Typical passive probes with high input R and C provide good response at lower frequencies, but inappropriately load the circuit, and distort signals, at higher frequencies. The ZS Series features both high input R (1 MΩ) and low input C (0.9 pF) to reduce circuit Loading across the entire probe/oscilloscope bandwidth. The ZS2500 is ideal for 2.5 GHz and lower oscilloscopes.
-
product
Water Cooled Active Resistance DC Electronic Load
WRx Series
Utilizing Magna-Power’s new patent pending Active Resistance Technology in combination with the company’s internally manufactured microchannel water-cooled heatsinks, the WRx Series addresses high power DC applications where exhaust heat control is essential. The WRx Series greatly increases power density compared air-cooled alternatives. An integrated solenoid controls the flow of water to avoid condensation. Full power can be achieved using conventional water, with water inlet temperatures up to 25 °C.
-
product
75-Watt AC/DC Power Supply; Triple Output
56KT1
NAI’s 56KT1 is a 75 Watt AC/DC Power Supply that accepts multiple AC inputs plus a +270 VDC input. This COTS unit provides full-power, triple output, at a baseplate temperature of +85° C.
-
product
Optical Spectrum Analyzer Module Specification
CA92001B
UCINSTRUMENTS CA92001B C band optical spectrum analyzer module is a spectral engine for Process Analytical Technology applications. The OSA module acts as a stand-alone spectral engine, imaging and measuring a wide range of vapors, liquids and solids through transmission and diffuse reflection in a rapid non-destructive process. Leveraging our proprietary Micro-Optic technology, UC INSTRUMENTS’ C band OSA module features the following characteristics: (1) compact; (2) light-weight; (3) low power consumption; and (4) wide wavelength coverage. These characteristics of UC INSTRUMENTS’ compact OSA engines are suitable for a variety of handheld, portable or bench-top OSA/spectrometer applications. Equipped with a state-of-the-art internal wavelength reference, the OSA module is capable of precisely measuring optical spectrum. Because it does not require an expensive InGaAs detector array, the compact OSA module is a cost-effective alternative to other grating-based OSA/spectrometer engines. The OSA communicates with a PC or an instrument motherboard via an USB interface. UCINSTRUMENTS’ OSA module platform can be installed or co-packaged into existing NIR OSA/spectrometers as a cost-efficient alternative to other scanning optical engines.
-
product
Infrared Radiometers
Calibrated to a custom black-body cone with a measurement uncertainty of 0.2 C from -30 to 65 C when the sensor (detector) temperature is within 20 C of the surface (target) being measured. Radiometers are only sensitive from 8 to 14 m (atmospheric window) to minimize the influence of water vapor and CO2 on the measurement.
-
product
COMPUTERIZED AUTOMATIC RELAY TEST SYSTEM
CVRT-S16
CVRT-S8 & S16 are ideal for automatic testing of ELECTRO MECHANICAL AND READ RELAYS (only DC relays) both for static and dynamic characteristics. This system scans at one stroke, all the parameters of the relay as per definition of test procedure. The test sequence can be pre-programmed and stored in the disk. You can select the tests as per your requirement. Can include or exclude the test and you can have several options to match your test definitions. Semi skilled person can be engaged for actual testing, as he need not make any settings and need not interpret the readings. The system conducts the tests and gives PASS / FAIL indication on overall test results. If a printer is connected, each test result will be printed.Test Parameters : -> Coil Resistance.-> PickUp/Pull In /Operating Voltage or Current Linear Ramp Method or Step Method.-> Measure Pickup Contact Gap FBB-LBB V or mA-> DropAway/Drop Out/Release Voltage or Current Linear Ramp Method or Step Method.-> DropAway Contact Gap FFB-LFB V or mA-> % Release Dropaway/Pickup-> Contact Resistance of all contacts both Front and Back contacts.-> Operating Time @ Set Voltage or Current.-> Contact Bounce or Chattering Time while Operating @ above-> Release Time @ Set Voltage or Current.-> Contact Bounce or Chattering Time while release @ above-> Difference of Operate Time - Release Time.-> Bridging Test or Non Overlap Test.-> Transfer or Traverse Times while Operate and release.-> Operate Time @2nd Set Voltage or Current.-> Release Time @2nd Set Voltage or Current.-> Power Consumption @ Rated Voltage.-> Coil Current @ Rated Voltage at Room Temperature.-> Coil Resistance Corrected to 20deg C.-> Timing Waveform Graph for all active Contacts.
-
product
Waveguide Electromechanical Relay Switches
Pasternack's waveguide electromechanical relay switches offer full waveguide performance covering C, X, Ku, K and Ka frequency bands. Waveguide electromechanical relay switch components from Pasternack cover various frequency ranges from 5.85 GHz to 40 GHz depending on the model. These waveguide switches are ideal for applications that include electronic warfare, electronic countermeasures, microwave radio, VSAT, SATCOM, radar, research and development, space systems and test instrumentation.
-
product
AC/DC Power Supply 4 W
RAC04-3.3SK/277
AC/DC power supply with 4 W from Recom | input ranges 80 - 308 VAC | output 3.3 V | operates in temperature from -40 to +90 °C | only available on request
-
product
C Series Sound And Vibration Input Module
The C Series Sound and Vibration Input Module incorporates software-selectable AC/DC coupling, IEPE open/short detection, and IEPE signal conditioning. The input channels simultaneously measure signals. Each channel also has built-in anti-aliasing filters that automatically adjust to your sample rate. The modules are compatible with smart TEDS sensors.The C Series Sound and Vibration Input Module includes the NI-DAQmx driver and configuration utility that simplify configuration and measurements. NI-DAQmx supports NI programming environments as well as Python, ANSI C, C#.NET, and MathWorks MATLAB® software.
-
product
Network Simulation Platform
OMNeT++
OMNeT++ is an extensible, modular, component-based C++ simulation library and framework, primarily for building network simulators. “Network” is meant in a broader sense that includes wired and wireless communication networks, on-chip networks, queueing networks, and so on. Domain-specific functionality such as support for sensor networks, wireless ad-hoc networks, Internet protocols, performance modeling, photonic networks, etc., is provided by model frameworks, developed as independent projects. OMNeT++ offers an Eclipse-based IDE, a graphical runtime environment, and a host of other tools.
-
product
Reach-In Conditioning Test Chamber
Weiber Conditioning Test Chamber Manufacturers offers an ideal apparatus for conditioning materials at non-ambient temperatures. Now researchers, engineers, and technicians have a simple and cost effective method to condition samples prior to testing. Laboratory Conditioning Chamber is designed for the conditioning of samples prior to testing, provides conditions from 20% to 98% RH ± 2 and 0°C to 94°C ± 0.5°C.Conditioning Test Chambers offers ideal humidity and temperature conditions required for testing the effect of environmental changes on the product. The chamber can be widely used to evaluate the durability of various products. Weiber delivers customized products at the most economical rate and within the limited delivery period.
-
product
LGA 1200 Intel® Xeon® W & 10th Gen. Core™ MicroATX Server Board with 4 x DDR4, 3 x PCIe, 6 x USB 3.2, 5 x SATA3, Quad/Dual LANs, and IPMI
ASMB-587
- LGA 1200 Intel® Xeon® W and 10th Gen. Core™ i9/i7/i5/i3 processor with W480E chipset- DDR4 ECC/Non-ECC 2933/2666/2400 MHz UDIMM up to 128 GB- One PCIe x16 and 2 x PCIe x4 slots- Triple displays - DVI-D, VGA, and HDMI 2.0 ports- Five SATA 3 ports and six USB 3.2 ports- One M.2 22110/2280 (SATA / PCIe compatible)- 0 ~ 60 °C (32 ~ 140 °F) ambient operating temperature range
-
product
6U Processor Board
CP62102
LinkedHope Intelligent Technologies Co.,Ltd.
CP62102, a product designed by LinkedHopeTM, is a 6U CPCI processor board based on Intel QM77/HM76 platforms supporting 3rd generation Intel i series CPU, up to 2.7GHz frequency, HD4000 integrated core graphics and dual-channel SO-DIMM memory (1333/1600) with up to 16GB DDR3 ECC (optional) and up to 64GB on-board SSD storage.CP62102 provides VGA and HDMI display and supports different display terminal output. CRT displays up to 2048x 1536. Besides CP62102 provides a wealth of software drivers (BSP) support, including Windows7, Windows Vista, Windows XP, WES 7, VxWorks, Linux, etc., as can reduce system integration workloads and end application development efforts, so to shorten time to market.
-
product
Bench Digital Multimeter, Calibrated D & U, 1 kV, 10 A, 3.8 Digit
72-1015 CAL DU
The 72-1015 CAL DU from Tenma is a digital bench type true RMS multimeter. It has auto and manual range options with maximum reading of 5999 counts and 3-5/6 digits which has a unique outlook design. In addition to all the conventional features including DC/AC voltage, current, resistance, diode, continuity test, diode test capacitance, temperature, transistor, max/min, there is a data hold, low battery display, sleep mode, RS232C serial port for easy connection with computer to realize macro recording, monitoring and capture of transient dynamic data, displaying change of waveform during the measurement, providing data and evidence to engineering technicians for scientific research. This meter complies with the standards IEC61010, pollution degree 2, overvoltage category (CAT I 1000V, CAT II 600V) double insulation and CE marked.
-
product
Thermalert Monitoring Thermometer
TH-5
The TH-5 is one of our most economical precision thermometers in the Physitemp product line. The TH-5 offers the same high accuracy (0.1°C ±1 digit) and resolution as all our other thermometers, but with a narrow temperature range. The TH-5 is ideally suited for either a laboratory or hospital setting where continuous temperature readings within the physiological range are sufficient.
-
product
Hazardous Location Syringe Pump
260HLf
Teledyne LABS HLf-Series pumps give you the same accurate, predictable flow and pressure control as our standard D-Series, while conforming to safety standards for use in UL Class I, Division 2, Groups A B C & D, T4 environments. The hazardous location rating is achieved through internal design modifications including the use of brushless DC motors. This approach eliminates the need for purge boxes or other additional safety devices. Wetted materials are compatible with most aqueous and organic liquids, corrosive solutions, heated fluids, liquefied gases, viscous fluids, or slurries and pastes. If needed, optional materials such as Hastelloy C-276 are available on request. The HLf controller has a keypad and LCD, as well as built-in and optional interfaces for computer control and other devices. Programming is easy and flexible, with instant access to menu screens even when the pump is running. This allows you to change operating parameters on the fly.
-
product
PCI GPIB Controller Card
Model 488-LPCI
* Adds GPIB Controller capability to any PC with a PCI bus.* Fast >1 Mbs transfer rate* 488.2V4 Driver supports 32 and 64-bit Windows XP, Vista, Windows 7, Windows 8 and Windows 10 with a true 64-bit DLL.* Driver compatible with industry standard 'ib' and '488.2' command sets.* Most affordable PCI-GPIB controller with a industry standard GPIB-32.dll.* Works with Agilent, NI and Kikisui VISA libraries.* ICS's Explorer auto configures your controller as it finds your instruments.* Use ICS's Explorer to control GPIB devices without having to write a program. * Program with Visual Basic, C, LabVIEW, Matlab or Agilent VEE* GPIB Card supports HP-IB Bus Systems.* Includes short bracket for lo-profile chassis.
-
product
Standard 1.71 (48.00) - 3.00 (85.00) General Purpose Probe
HPA-74T156
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Test Center Remark: max. test center 187 mil / 4,74 mmFull Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 75Recommended Travel (mm): 1.91Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 598Overall Length (mm): 15.19Overall Length Remark: Tip “A-B”: 598 (mil), 15.19 (mil), Tip “C”: 586 (mil), 14.88 (mil), Tip “E, T135, T156, T65, T80”: 610 (mil), 15.49 (mil), Tip “T75”: 620 (mil), 15.75 (mil)
-
product
XMC-to-PCI Express Adapter
7988
The Technobox, Inc. P/N 7988 is designed to adapt a single-wide XMC card to a 16X PCI Express slot. The 7988 supports both P15 and P16 and allows access to PN4 signal via the adapter's DIN connector. The A and C rows of a 96-pin DIN connector connect with the 64-pin user I/O connector (J4/P4) on the mezzanine card, permitting internal connection of rear I/O.