Rubidium Standards
In telecommunication, a rubidium standard is a frequency standard in which a specified hyperfine transition of electrons in rubidium-87 atoms is used to control the output frequency. (www.encyclopedia.thefreedictionary.com)
See Also: Rubidium Reference, Rubidium Oscillators, Frequency Standards, Rubidium Frequency Standards
-
Product
Standard 1.10 (31.00) - 3.85 (109.00)General Purpose Probe
SPA-64-1
-
Current Rating (Amps): 3Average Probe Resistance (mOhm): 50Test Center (mil): 100Test Center (mm): 2.54Test Center Remark: max. test center 187 mil / 4,74 mmFull Travel (mil): 50Full Travel (mm): 1.27Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 375Overall Length (mm): 9.53Overall Length Remark: Exact length depends on selected tip: Tip 1,4, 7: 0,375″; Tip 2,3: 0,365″; Tip 8: 0,385″; Tip ,9,10: 0,363″
-
Product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Lead Free Probe
LFRE-1L-4
-
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Mechanical Life Remark: *Ultra High force products may observe slight decrease in cycle life.Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Standard - 5.00 (142.00) - 8.30 (235.00) Feed Through Probe
P3325-0
-
Current Rating (Amps): 10Average DC Resistance lower than (mOhm): 10Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 66Recommended Travel (mm): 1.68Overall Length (mil): 645Overall Length (mm): 16.38
-
Product
Standard 0.62 (18.00) - 5.40 (153.00) Probe
LFRE-39I15-5.4
-
Current Rating (Amps): 2Average Probe Resistance (mOhm): 50Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 50,000Overall Length (mil): 1,437Overall Length (mm): 36.50
-
Product
Standardized Bus Interface
IP-429-II
-
Connect to your Avionics with IP-429. Pick 2,4,6,or 8 ARINC 429 compatible receivers and 1, 2, 3, or 4 transmitters. Transorb protected IO. Software programmable transmit rates [100K or 12.5K]. Time Tag on received data. IndustryPack campatible with 8 or 32 Mhz. bus operation.
-
Product
Standard M12 Cylindrical Photoelectric Sensors
-
Contrinex Standard M12 Cylindrical Photoelectric Sensors
-
Product
Standard 1.68 (48.00) - 3.20 (91.00) General Purpose Probe
HPA-52D
-
Current Rating (Amps): 3Average Probe Resistance (mOhm): 15Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 75Full Travel (mm): 1.91Recommended Travel (mil): 75Recommended Travel (mm): 1.91Mechanical Life (no of cyles): 250,000Overall Length (mil): 629Overall Length (mm): 15.98
-
Product
Standard 1.68 (48.00) - 3.20 (91.00) General Purpose Probe
HPA-52T
-
Current Rating (Amps): 3Average Probe Resistance (mOhm): 15Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 75Full Travel (mm): 1.91Recommended Travel (mil): 75Recommended Travel (mm): 1.91Mechanical Life (no of cyles): 250,000Overall Length (mil): 629Overall Length (mm): 15.98
-
Product
Analytical Reference Materials & Standards
-
Agilent, now with former Ultra Scientific, offers a comprehensive portfolio of analytical standards, reference materials and certified reference materials for environmental, food safety, elemental analysis, instrument calibration, tuning mixes, and more.Reference materials and certified reference materials are substances that are tested to be homogenous and have fixed values of its concentrations. These standards are a critical component of your application workflow - from sample prep, instruments, columns, supplies, and services. The success of your analysis depends upon the quality of your reference material. All Agilent standard reference materials have been manufactured to the highest quality in an ISO 9001, ISO 17025 and 17034 accredited facilities to ensure the accuracy of your analyses.If you need a custom reference material, partner with us to design and develop a custom standard to your specifications.
-
Product
Standard 1.50 (43.00) - 4.00 (113.00) High Performance Lead Free Probe
LFRE-25T30-4
-
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
ANSI Standard Burden Sets
Voltage and Current
-
Testing and calibrating instrument transformers often requires standard burdens of reliable accuracy and stability, and burdens that are immune to stray fields and harmonics. The burden sets described below have been carefully designed to meet these requirements.
-
Product
Standard 0.79 (23.40) - 1.75 (49.60) General Purpose Probe
HPA-40C
-
Current Rating (Amps): 2Average Probe Resistance (mOhm): 35Test Center (mil): 39Test Center (mm): 1.00Full Travel (mil): 75Full Travel (mm): 1.91Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 660Overall Length (mm): 16.76
-
Product
Standard 1.10 (31.00) - 2.50 (71.00) General Purpose Probe
HPA-1J
-
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 655Overall Length (mm): 16.64
-
Product
Standard 3.06 (86.70) - 4.00 (113.40) RF Probe For SMA Connectors
CSP-30ES-013
-
Nominal Impedance (Ohms): 50Current Capacity (Amps) @ 20° C: 1.00Bandwidth @ -1dB (GHz): 35.00Return Loss @ -20dB (GHz): 22.00Test Center (mil): 328Test Center (mm): 8.33Recommended Travel (mil): 100Recommended Travel (mm): 2.54Full Travel (mil): 200Full Travel (mm): 5.08Overall Length (mil): 1,033Overall Length (mm): 26.24Rec. Mounting Hole Size (mil): 297Rec. Mounting Hole Size (mm): 7.54
-
Product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Bias Ball Probe
POGO-1T-4
-
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Standard 1.10 (31.18) - 4.80 (136.00) Switch Probe
TSP100-H180-1
-
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 20Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 197Full Travel (mm): 5.00Recommended Travel (mil): 157Recommended Travel (mm): 4.00Overall Length (mil): 1,990Overall Length (mm): 50.60Switch Point (mil): 59Switch Point (mm): 1.50
-
Product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Lead Free Probe
LFRE-1UN-4
-
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Mechanical Life Remark: *Ultra High force products may observe slight decrease in cycle life.Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Standard Test Chambers
-
HIACC Engineering & Services Pvt. Ltd.
Designed for testing the durability, safety, and performance of products under various conditions.
-
Product
STANAG3910/EFEX Test And Simulation Module for Standard Ethernet
ANET3910
-
STANAG3910/EFEX Test and Simulation module for Standard Ethernet. The ANET embedded Linux Operating System gives the unique capability to run the optional PBA.pro Engine right in the box. Another option is the ANET-ADK onboard software development kit where users create run-time applications (e.g. STANAG3910/EFEX to Ethernet Converter, STANAG3910/EFEX to Ethernet Gateway) to execute right in the box. For wireless applications, an ANET compatible USB Wifi dongle is optionally available.The capability to execute Python scripts in the ANET is a standard feature. For applications with multiple ANET devices AIM offers the ADock ANET Docking Station to host up to 4 ANET modules.
-
Product
Standards Waveform Generator
3110A
-
The 3110A software is built around the simple concept of a waveform segment. Each waveform segment can have a unique waveform, (sine, square, triangle, and/or DC offset). Frequency, amplitude and DC offset can be clipped, fixed, variable or swept. Segments can be calibrated (as required in CS101) and set to continue on to the next segment or to hold for an external trigger.
-
Product
Standard 1.71 (48.00) - 3.00 (85.00) General Purpose Probe
HPA-74C
-
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Test Center Remark: max. test center 187 mil / 4,74 mmFull Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 75Recommended Travel (mm): 1.91Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 598Overall Length (mm): 15.19Overall Length Remark: Tip “A-B”: 598 (mil), 15.19 (mil), Tip “C”: 586 (mil), 14.88 (mil), Tip “E, T135, T156, T65, T80”: 610 (mil), 15.49 (mil), Tip “T75”: 620 (mil), 15.75 (mil)
-
Product
Standard 1.50 (43.00) - 4.00 (113.00) High Performance Lead Free Probe
LFRE-25H79-4
-
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Hydrogen Frequency & Time Standard
CH1-1035
-
Hydrogen frequency and time standard Ch1-1035 is designed for precision storage and reproduction of the size of frequency and time units as part of measures and reference complexes.
-
Product
Standard 0.39 (11.00) - 1.39 (39.00) Replaceable General Purpose Probe
MEP-30G
-
Current Rating (Amps): 2Average Probe Resistance (mOhm): 50Test Center (mil): 30Test Center (mm): 0.76Full Travel (mil): 75Full Travel (mm): 1.91Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 690Overall Length (mm): 17.53
-
Product
Standard RF Fixture
-
The standard RF fixture supports both pulsed and non-pulsed operation. It employs SMA input/output connections. For RF output powers over 10W, an N-type connector may be used to replaces the SMA connector because of its power-handling capability.
-
Product
Standard 0.95 (26.90) - 4.50 (128.00) Battery Probe
CP-2LB-12
-
Current Rating (Amps): 5Average Probe Resistance (mOhm): 50Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 128Full Travel (mm): 3.25Recommended Travel (mil): 118.1Recommended Travel (mm): 3.00Overall Length (mil): 472Overall Length (mm): 12.00Overall Length Remark: Overall length does not include tail.Recommended Drill Size: #53 or 1.51 mmRec. Mounting Hole Size (mil): 61Rec. Mounting Hole Size (mm): 1.55
-
Product
Standard 1.71 (48.00) - 3.00 (85.00) General Purpose Probe
HPA-74T156
-
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Test Center Remark: max. test center 187 mil / 4,74 mmFull Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 75Recommended Travel (mm): 1.91Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 598Overall Length (mm): 15.19Overall Length Remark: Tip “A-B”: 598 (mil), 15.19 (mil), Tip “C”: 586 (mil), 14.88 (mil), Tip “E, T135, T156, T65, T80”: 610 (mil), 15.49 (mil), Tip “T75”: 620 (mil), 15.75 (mil)
-
Product
Phase Angle Voltmeter, Industry Standard
2250A
-
NAI's 2250A Phase Angle Voltmeter is the most accurate and versatile AC measurement tool in the Synchro/Resolver and LVDT/RVDT marketplace. Considered the industry standard and based on the latest DSP and FPGA technologies, the 2250A substantially extends and simplifies the capabilities of the legacy 2250 model.
-
Product
Barcode Conformance Calibration Standards
-
Barcode symbol quality has been at the forefront of discussion among practitioners in the automatic identification and data capture (AIDC) industry since they were invented in 1951. Barcodes became commercially successful when they were used to automate checkout systems at grocery stores, with the very first scanning of the Universal Product Code (UPC) on a pack of Wrigley Company chewing gum in June 1974. The Uniform Code Council (UCC) published barcode quality guidelines, and ANSI X3.182-1990 became the first published standard for barcode quality. Since then, ISO/IEC 15416 for 1D symbols and ISO/IEC 15415 for 2D symbols have become the global standards for grading printed barcodes.