Product
PXI 64-Channel Digital Output Module
40-412A-021
Digital Output Module
The 40-412A-021 (PXI) and 42-412A-021 (PXIe) are 64-Channel Digital Output modules with high output voltage and current capability. The outputs can be used for high or low drive and each channel is capable of sourcing 0.5A from the high side or 0.5A sink on the low side. Accidental operation of both high and low side driver on the same channel is prevented by the supplied driver. Outputs are fully protected against over-voltage, over-current and thermal overload, ensuring robust and reliable operation in the toughest test environments. For high side driving, the voltage source is supplied externally, allowing the module to drive high capacity loads separate from the chassis power supply. For low side driving, the external source is not used and the module’s output operates an open collector or open drain driver.
-
Product
OHMMETERS
DOT-1000-2
-
Model DOT-1000-2, is an ac four-terminal ohmmeter to be used for the measurement of dynamic ac resistance of batteries, fuel cells and other voltage sources.
-
Product
Primary Current Injection Test Trolley
-
SCR ELEKTRONIKS have developed primary and secondary Current injection test trolley for Switchgear manufacturers for testing of ACB , MCB , MCCB. It is low Voltage high Current source with control circuitry, digital read out for test current and trip time measurement. We can select different links of CT range as per the required test Current.
-
Product
PathWave BenchVue USB Modular SMU Pro
BV0023B
-
The PathWave BenchVue USB modular SMU pro software configures voltage and current source, range and limit for each SMU channel and log unrestricted data.
-
Product
Three Phase Site Energy Meter Test Instrument Type KP-P3001-A
-
Bofa Instrument & Equipment Co., Ltd
Three-phase site energy meter test instrument type KP-P3001-A (without voltage and current source) is an ideal instrument to test all kind three-phase energy meters accuracy below 0.2, especially for meters on site. When we want test a meter errors, the tested meter must be on load condition (or we can say the tested meter must be working). The instrument can test the errors, by comparing energy impulse from the tested meter with energy impulse from the reference meter which inside the instrument. The equipment is box structure and weight is very light, easy to carry, it is very convenience to test the installed meters on site.
-
Product
Load Cell Power Supply
MODEL PSMR
-
The PSM-R is a self contained AC power bridge excitation supply. This device consists of a low interwinding capacitance AC transformer and a high stability adjustable linear regulator designed specifically for driving transducer bridges. DC excitation is adjustable from 4 to 15 volts output and is capable of supplying 0 to 150 mA in output current. It features remote sensing to eliminate line drop errors and very low noise. It can also be used as a high quality voltage source or reference in many applications. AC input requirements are 105 to 125 VAC at 60 Hz.
-
Product
Three-phase Fully Automatic Test System
TS41
-
Calmet Smart Calibration Devices
The Calmet TS41 test system consists of a three-phase reference meter of accuracy class 0.02% (or 0.04%) and an integrated three-phase current and voltage source up to 3x120A/600V. It makes possible automatic testing of electricity meters in meter test stations
-
Product
Transistor Tester
-
*Measure rich DC parameters of maniford semiconductors, e.g. diode, transistor, controlled silicon, FET.*Measure capacitor, varistor, DC voltage signal source*Measure 78 and 79 three terminal voltage regulator*Data hold, low battery warning*Complete with carry case and six 1.5V AA batteries
-
Product
Digital kV Meter
VM-10, VM-20 , VM-30
-
UDEYRAJ ELECTRICALS PRIVATE LIMITED
High Voltage Meters measure AC and DC voltages of up to 30kV with high accuracy. The meter input impedance is as high as 1000 M ohm, making the meter suitable for measurement of voltages of high source impedance circuits. Meters are compact and light weight and can be conveniently used as a calibration meter.
-
Product
Withstand Voltage Tester
2672AM
-
Shenzhen Chuangxin Instruments Co., Ltd.
Withstand Voltage Tester is used to measure the dielectric (withstand voltage) strength, which can be intuitive, accurate and fast tested the electrical safety performance indicators of the object, such as the breakdown voltage, leakage current etc. And Withstand Voltage Tester can be used as a high voltage source to test performance of the components and whole machine.
-
Product
Three Phase Portable Energy Meter Calibration Equipment
GF302D1
-
Beijing GFUVE Electronics Co.,Ltd.
The GF302D1 three phase portable energy meter test system consists of an integrated three phase current and voltage source(up to 500V/120A or 500V/20A) and built-in three-phase electronic reference standard of accuracy class 0.05%. Characteristic features of the GF302D1 are its wide measuring range, high accuracy and high tolerance to unwanted external influences. The equipment offers high functionality combined with an excellent menu guided operation via built-in keyboards and colored 7" touch LCD-display.
-
Product
16-Bit Digitizer
PA72D16180A
Digitizer
The PA72D16180A is a 16-bit digitizer, capable of capturing waveforms at speeds up to 180Msps. An onboard offset voltage source allows capturing offset signals while still using the optimal range for maximum ADC utilization. Two onboard filters allow suppression of out-of-band noise. The 64MWord onboard memory enables capturing very long waveforms, or sequentially capturing multiple signals with minimal intermediate bus communication.
-
Product
Shunt Regulators
-
These are the standard reference voltage source widely used by the feedback circuits of switching power supplies. Compared to the Zener diode, which is a discrete product, a shunt regulator has much better voltage precision because voltage control is carried out as an IC.
-
Product
Single Phase Site Energy Meter Test Instrument Type KP-P1001-A
-
Bofa Instrument & Equipment Co., Ltd
Single phase site energy meter test instrument type KP-P1001-A (without voltage and current source) is an ideal instrument to test all kind single phase energy meters accuracy below 1.0, especially for meters on site. During tests, the tested meter must be on load condition (that means the tested meter must be working). The instrument tests the errors by comparing energy impulse from the tested meter with energy impulse from the reference meter inside the instrument.
-
Product
Isolated Voltage Source
SIM928
-
Stanford Research Systems, Inc.
The SIM928 Isolated Voltage Source is ideal for applications where ultra-clean DC voltage is required. Voltage can be set between ±20 VDC with millivolt resolution, and the source can drive up to ±10 mA
-
Product
Variable Frequency Modules
9554-( )
-
Utilizing the high voltage power source in the Model 9354-1 Universal Transient Generator, four individual modules can be connected to provide tuning of damped sine waves from 10 KHz to 50 MHz. A fifth module is available which, when used in conjunction with the Model 9354-1, provides 20% frequency steps from 30 MHz to 100 MHz
-
Product
Single Channel USB Programmable High-Pass Filter
USBPHP-S1
-
The USBPHP-S1 stand alone USB controllable module provides a single channel of high pass filtering and high-quality instrumentation amplifier for front-end signal conditioning compatible with all popular A/D converter devices. The USBPHP-S1 is powered with 9 to 12VDC so it can be connected to a battery voltage source or the supplied 115-220VAC adapter may be used for operation with wall power anywhere in the world. When programmed from the USB port, the USBPHP-S1 will remember all of the programmed properties between power cycles. Program once and operate as a stand- alone signal conditioner without having to reprogram for every use. This is perfect for turn-key applications. It's easy to connect the USBPHP-S1 into the data collection system. Input and output signals can be routed through BNC connection or using the detachable screw terminal connectors. Optional SMA type adapters are also available.
-
Product
Variable AC/DC Power Supply
UPS S2
-
The Vanguard Universal Power Supply Series 2 (UPS-S2) is designed and produced to meet a utility company’s substation needs for an independent AC/DC power source. Both the AC and DC Voltage sources are capable of supplying 10 amperes continuously.
-
Product
Three-Phase Relay Test Equipment
AK-10
-
The new AK-10 three-phase relay test equipment from Amperis features AC and DC Voltage Source ; AC Current Source ; AC/DC Auxiliary Power Source ; 8 possible configurations.
-
Product
Power Sources
GF303
-
Beijing GFUVE Electronics Co.,Ltd.
GF303 Program-controlled three phase AC standard power source is a high precision three phase AC standard current source and AC standard voltage source.
-
Product
Digital Sensors
PMA-Series
-
Solar Light’s NIST-Traceable PMA-Series Digital Sensors represent the pinnacle of accuracy, durability, and selection on the market today. Our sensors measure discrete bands of the electromagnetic spectrum from the UVA, UVB, UVA+B, UVC, Visible Light, and Infrared regions. Both narrow and broad bands are available to fit any application, including germicidal requirements, environmental probes, and sensors for biologically weighted spectra (such as the erythema and CIE action spectra.) Over 135 different sensors are available in a variety of packages to fit any environment, from indoor clean rooms to harsh locations outdoors to 100 meters under water. Please note that Solar Light offers both Digital Sensors and Analog Sensors in the PMA-Series lineup. Select these Digital Sensors if you prefer to plug into our PMA-Series Radiometers to read the output of the sensor on the meter’s display. Digital models are typically used as discrete sensors that are portable and located to provide short term information. (By contrast, please select Analog Sensors if you don’t need a digital display output of the reading, if you will be connecting to your own datalogger, or if you plan to use a voltage source to provide excitation voltage to the sensor and a digital volt or amp meter to read and convert the results. Analog Sensors are typically used as process sensors that are permanently installed to provide ongoing information.)
-
Product
Partial Discharge Measurement System
DAC-6021
-
DAC-6021 is a measurement system for testing Partial Discharge of high frequency equipment, power devices, stator coils, etc.Since the system combines Partial Discharge Measuring Instrument (DAC-PD-3) with Testing Corona-free Variable Frequency Voltage Source (DAC-WT-50) and Testing Shielded Chamber, most external noises are removed, and the measurement is safe.
-
Product
PID Testing Equipment
-
The potential induced degradation (PID) is addressed with the standard IEC TS 62804-1. The standard defines two methods that enable analyzing occurring PID effects in a specific PV module type. PSE AG offers the necessary equipment for the test in a climate chamber. The test equipment can work with any climate chamber on the market and is delivered turnkey. It comes with all necessary equipment, high voltage power sources, sensors, data acquisition and software.
-
Product
Nodal Impedance Analyser
QT-Hi1
-
Qmax Test Technologies Pvt. Ltd.
QT-Hi1 is an innovative Nodal Impedance Analyzer, which uses the industry’s proven V-I trace techniques of learn and compare of nodal impedances which are represented as VI Curves. It uses innovative Auto Best Curve fit technique an intelligent software alogorithm which enables automatic selection of the best fit value of Voltage, Source Impedance and Frequency of the stimulus waveform. The compact size with re-chargeable battery makes it an ideal companion for on-field applications. The wide 8” touch screen graphical display makes this tool more valuable in test and repair industry at all times.
-
Product
ITSM Synchro
-
The Impulsive Test Synchronization Module (ITSM) is a device aimed at generating a digital synchronization signal, to use the PDBaseII system for impulsive voltage PD test. The digital synchronization signal generated by the ITSM, is synchronized with the voltage impulse of the impulsive source (voltage generator). The ITSM must be connected between the DIN channel of PDBaseII and the output of the synchronization sensor (e.g. capacitive coupler). The ITSM provides also a low voltage signal reproducing the impulsive voltage source.
-
Product
Lamp Converters
-
PeakTech Prüf- und Messtechnik GmbH
This AC / AC voltage converter is particularly suitable for use with halogen indoor lights and other low-voltage light sources that require an AC voltage source for supply. There is a safe galvanic separation between mains and low voltage according to the isolating transformer standard. This pre-assembled AC / AC converter is equipped with an overtemperature switch that cannot be reset.
-
Product
PCI Relay Driver Card, 64-Channel
50-411A-001
Relay Driver
The card provides 64 channels of low side switching for external relays. Users need to simply connect a positive voltage source to one terminal of a relay coil and the other terminal to an output of the 50-411A. Each output is capable of sinking up to 1A of continuous current.
-
Product
High Voltage SMU
-
Source and Measurement Units (SMUs) are devices that generate voltages or currents and can measure them simultaneously using the integrated measuring units (VMU, CMU).High-voltage SMUs work as a regulated voltage source and are able to generate very high output voltages.
-
Product
Loop Calibrator
Model KM CAL-904-MK1
-
Kusam Electrical Industries Limited
• 4-20mA (1kΩ Load, 24V Loop Output).• 0-20mA and 0-24mA output ranges.• 0.025% Basic Accuracy.• Auto Ramp and Step functions.• 0-100% output with percentage step option.• 0-24V DC voltage source.• Open loop and overload buzzer alarm.• Low battery indication.• Simple Operation Interface• Warning beeper when output is open• Pollution Degree 2.• Ambient temperature 0~40℃.• Power Consumption 150mA at 24V 1kΩ load
-
Product
Low Power Potentiostats
-
Potentiostat Wenking MP 04T, max. current 400 mA, max. voltage 25 V, output power 10 W, reference electrode input 1012 Ohms, slew rate 10 V/ µs, 1 control input, floating current output, buffered potential output, control range ± 10 V external, internal control voltage source ±2 V, rise time constant (closed loop, ohmic load) 1 µs typ., dimensions 165 x 105 x 165 mm (w x h x d), weight 1.4 kg