-
Product
PXI/PXIe Fault Insertion Switch, 74-Chan 2A, N/C Through Relays, Fault Buses on M & U
42-190C-012
Fault Insertion Unit
The 40-190C-012 (PXI) and 42-190C-012 (PXIe) are fault insertion switches with 74 channels. They are part of a range of modules available with 74, 64 or 32 channels and are primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers.
-
Product
20/26 Ghz Coax, Module Insert, Receiver, i2 MX, 5 Position
510143008
Receiver Module Insert
20/26 Ghz Coax, Module Insert, Receiver, i2 MX, 5 Position.
-
Product
Signal, Insert Bundle, Receiver, QuadraPaddle, SIM, Right Angle and Pass-Thru
510180107
SIM Insert
Signal, Insert Bundle, Receiver, QuadraPaddle, SIM, Right Angle and Pass-Thru.
-
Product
3 Function Slot MOSA Nano Data Concentrator Unit (DCU)
NIU3A-DCU-01
Data Concentrator Unit
NIU3A-RDC-01 is a Modular Open Systems Approach (MOSA) Data Concentrator with low power high performance ARM Cortex -A53 processing. 8 GB RAM, 32 GB SATA Flash, 2 x 10/100/1000Base-T Ethernet.
-
Product
PXIe-4138, 60 V, 3 A System PXI Source Measure Unit
782856-01
Source Measure Unit
±60 V, 3 A System PXI Source Measure Unit—The PXIe‑4138 system source measure unit (SMU) delivers high power, precision, and speed. It is ideal for a broad range of applications including manufacturing test; board-level test; lab characterization with devices such as integrated circuits (ICs), power management integrated circuits (PMICs), and radio frequency integrated circuits (RFICs); and discrete devices including LEDs and optical transceivers. The PXIe‑4138 features 4-quadrant operation. The PXIe‑4138 is a hardware-timed instrument with a high-speed sequencing engine for synchronizing acquisitions between multiple SMUs. The module supports direct DMA streaming between the host PC and SMU, so you can stream large waveforms and measurement data at the full update rate and sample rate of the instrument.
-
Product
PCI Fault Insertion Switch Cards
-
Pickering's PCI Fault/Signal Insertion Switch Cards feature a breakout arrangement that allows faults to be attached to the sensor lines, this includes the breaking of a connection or the adding of defect all of which can simulate connectivity problems in the system.
-
Product
PXI/PXIe 1000Base-T1 Dual Multiplexer With Fault Insertion, Dual Channel
42-204-002
Multiplexer Module
The 40-204-002 (PXI) and 42-204-002 (PXIe) are dual channel differential multiplexers designed to simulate common faults on high-speed two wire communication interfaces such as 1000Base-T1. They are available with support for 1 or 2-channels of two wire serial interfaces. Each channel pair can be looped out to external equipment or the switches can be used simulate a channel open fault.
-
Product
PXIe-4139 , ±60 V, ±3 A DC, ±10 A Pulsed, 40 W DC, 100 fA Precision System PXI Source Measure Unit
782856-03
Source Measure Unit
PXIe, ±60 V, ±3 A DC, ±10 A Pulsed, 40 W DC, 100 fA Precision System PXI Source Measure Unit - The PXIe-4139 is a high-precision, system source measure unit (SMU) that features 4-quadrant operation and sources up to 40 W of DC power. This module features analog-to-digital converters that help you perform high-precision measurements with a current resolution of 100 fA or high-speed acquisitions up to 1.8 MS/s. The module can maximize stability and measurement accuracy with SourceAdapt technology, which you can use to tune the transient response to match the characteristics of any load. You can use the PXIe-4139 for applications including manufacturing test, board-level test, and lab characterization with devices such as ICs, power management ICs (PMICs), and RFICs and discrete devices including LEDs and optical transceivers.
-
Product
PXI 1A Fault Insertion Switch 11-Channel
40-195-101
Relay
The 40-195 is a 22 Channel Fault Insertion Switch, primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers. It is designed to be able to insert different fault conditions on pairs of signals between the test fixture and the equipment under test: Open-Circuit, Short-Circuit between signal pairs, Short-Circuit between signal pairs and user applied fault conditions e.g. Power or GND. Relays in-line with the signal paths allow open circuit conditions to be simulated on either side or both sides of a signal pair. Relays between each channel pair enable adjacent signals to be shorted, and relays between signal paths and the "Fault" connection allow the application of external user applied fault conditions.
-
Product
PXIe-4137, ±200 V, ±1 A DC, ±3 A Pulsed, Up to 40 W DC, 100 fA Precision System PXI Source Measure Unit
783761-01
Source Measure Unit
PXIe, ±200 V, ±1 A DC, ±3 A Pulsed, Up to 40 W DC, 100 fA Precision System PXI Source Measure Unit - The PXIe-4137 is a high-precision, system source measure unit (SMU). It features 4-quadrant operation and sources up to 40 W of DC power and can pulse up to 500 W. Analog-to-digital converter technology helps you perform high-precision measurements with a current resolution of 100 fA or high-speed acquisitions up to 1.8 MS/s. The module also can maximize stability and measurement accuracy with SourceAdapt technology, which you can use to tune the transient response to match the characteristics of any load. The PXIe-4137 is ideal for a broad range of applications including manufacturing test, board-level test, and lab characterization with devices such as ICs, power management ICs (PMICs), and RFICs and discrete devices including LEDs and optical transceivers.
-
Product
PXI/PXIe 1000Base-T1 Dual Multiplexer With Fault Insertion, Single Channel
42-204-001
Multiplexer Module
The 40-204-001(PXI) and 42-204-001 (PXIe) are single channel differential multiplexers designed to simulate common faults on high-speed two wire communication interfaces such as 1000Base-T1. They are available with support for 1 or 2-channels of two wire serial interfaces. Each channel pair can be looped out to external equipment or the switches can be used simulate a channel open fault.
-
Product
Insertion Flow Meter
SPI Mag
-
The SPI Mag Insertion Flow Meter provides a highly cost-effective solution for the accurate measurement of liquid flow in closed conduit, pressurized pipe applications. Unlike conventional magnetic meters, the SPI Mag's cost is independent of pipe size.
-
Product
PXI Fault Insertion Matrix Modules
-
All of our fault insertion matrices feature a breakout arrangement that allows faults to be attached to the sensor lines via the Y axis. This includes the breaking of a connection or the adding of a series defect – all of which can simulate connectivity problems in the system. The three pin breakout versions allow the connection to be swapped for a “bad” sensor simulation.
-
Product
4x 3U OpenVPX MOSA Actuator Interface Unit
SIU34-AIUVARM-01
Actuator Interface Unit
SIU34-AIUVARM-01 is a Modular Open Systems Approach (MOSA) DO-178C & DO-254 Certifiable Actuator Interface Units (AIU) with low power high performance OpenVPX Xilinx UltraScale+ SBC with Quad Core ARM Cortex -A53, 8 GB DDR4 SDRAM, 32 GB SATA Flash, 2 x 10/100/1000Base-T Ethernet, USB 3.0, FIPS-140-3 Level 3 Cyber Security, and Single Event Upset support.
-
Product
PXI/PXIe 1000Base-T1 Dual Multiplexer With Fault Insertion, Dual Channel
40-204-002
Multiplexer Module
The 40-204-002 (PXI) and 42-204-002 (PXIe) are dual channel differential multiplexers designed to simulate common faults on high-speed two wire communication interfaces such as 1000Base-T1. They are available with support for 1 or 2-channels of two wire serial interfaces. Each channel pair can be looped out to external equipment or the switches can be used simulate a channel open fault. Using the fault bus, switches can simulate a short between both wires or a short to one of two externally applied fault conditions – such as battery supply or ground - via two fault buses.
-
Product
PXI Dual Bus 64-Chan 2A Fault Insertion Switch, N/O Through Relays
40-190B-402
Fault Insertion Unit
The Dual Bus, 64 Channel PXI Fault Insertion switch is part of our family of 2 Amp fault insertion solutions, The range includes modules with 74, 64 or 32 channels and single or dual fault buses. This version has normally open through relays, so in the default state, there are no paths between inputs and outputs for any signal channel.
-
Product
Control Unit
Epec 5050
-
Epec 5050 Control Unit is ideal for applications that require plenty of I/O and enhanced algorithms. Epec 5050 control unit has also a large memory and its I/O is widely programmable. For example, PI pins’ threshold voltage can be selected and many inputs have pull-up/pull-down selection.
-
Product
Motor Unit
-
Adamant Namiki Precision Jewel Co Ltd.
Today, so many units products such as medical equipment, automobiles, fuel cells, robots, and precision instruments. These performances are supported by the performance of motors, on the other hand, mechanical design, parts processing, and control The maximize the performance of the motor, which is an engine, are indispensable . The functions required for unit products are very diverse, including precision drive , high output, light weight, low heat generation, low vibration, and low power consumption.Actuation technologies such as optimum motors, speed reducer, non-energized locking mechanism "dyNALOX", compact clutch mechanism, torque transmission mechanism, control, and our core technology "cutting" "sharpening" "polishing" precision We combine process parts and precision assembly technology and we propose the optimum solution with a unique idea unique to our company, which is a motor manufacturer.
-
Product
Fault Locator
TRANSFLEKT
-
TRANSFLEKT simplifies the location of transient faults on the low voltage distribution network.
-
Product
PXI Fault Insertion Switch, 6-Channel, Two Fault Buses, 30 A
40-191B-012
Fault Insertion Unit
The 40-191B is a PXI fault insertion switch using solid state switching elements and is capable of carrying 40A on single channel or 30A on all channels at the same time and provides a robust solution to high current fault insertion.
-
Product
PXI Fault Insertion Insertion Switch Modules
-
Our PXI Fault Insertion Insertion Switch Modules feature a breakout arrangement that allows faults to be attached to the sensor lines, this includes the breaking of a connection or the adding of defect – all of which can simulate connectivity problems in the system.
-
Product
Electronic Units
-
Electronic units for field installation and mounting rack installation control the actuators. They are fed with 115 or 230 V AC. A local control panel allows for easy basic settings.
-
Product
Fault Locator
REZAP FAULTMASTER
-
REZAP FAULTMASTER is an auto-recloser that keeps customers on supply during intermittent faults.
-
Product
Fault Locator
REZAP MODULAR
-
REZAP MODULAR brings full REZAP functionality to fuse panels with severe space restrictions
-
Product
UNI-T Series
-
Weshine Electric Manufacturing Co., Ltd
mainly used to measure the wire resistance of cables, the contact resistance ofswitches, connectors, relays, the resistance of coils, motors, transformer windings, and equipment enclosures, lightning protection belts, ground beams, structures, cabinets, steel bars, Test the connection resistance between metal components of water pipes, windows, guardrails, radiators, assembly lines, etc. It is widely used in telecommunications, electric power, meteorology, computer rooms, oil fields, power distribution lines, tower transmission lines, gas stations, factory grounding grids, lightning rods, etc.
-
Product
PXI 1A Fault Insertion Switch 22-Channel
40-195-001
Relay
The 40-195 is a 22 Channel Fault Insertion Switch, primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers. It is designed to be able to insert different fault conditions on pairs of signals between the test fixture and the equipment under test: Open-Circuit, Short-Circuit between signal pairs, Short-Circuit between signal pairs and user applied fault conditions e.g. Power or GND. Relays in-line with the signal paths allow open circuit conditions to be simulated on either side or both sides of a signal pair. Relays between each channel pair enable adjacent signals to be shorted, and relays between signal paths and the "Fault" connection allow the application of external user applied fault conditions.
-
Product
Piston Inserter
Atlas 2K
-
The Nordson EFD Atlas™ 2K Piston Inserter is a fast, convenient, and cost-effective way to install our revolutionary AF Air Free pistons in 50mL, 200mL, and 300mL Side x Side cartridges.
-
Product
50 µs Pulse Medium Current Source/Measure Unit (MCSMU)
B1514A
Source Measure Unit
The 50 s Pulse Medium Current SMU is an SMU designed for faster pulsed IV measurement. It enables a pulsed measurement down to 50 s pulse width, a 10 times or more narrow pulsed measurement than provided by a comparable conventional SMU. In addition, the instrument offers a wider range and versatility, up to 30 V / 1A, with voltage/current programmability. It is useful to characterize high to medium power devices on the new materials such as SiC and GaN, and organic devices, and the MCSMU expands your choices of pulsed IV measurement.
-
Product
PXI Dual Bus 74-Chan 2A Fault Insertion Switch
40-190B-002
Fault Insertion Unit
The Dual Bus, 74 Channel PXI Fault Insertion switch is part of our family of 2 Amp fault insertion solutions, The range includes modules with 74, 64 or 32 channels and single or dual fault buses. This version has normally closed through relays, so in the default state, there is a path between input and output for all signal channels. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers.





























