Fault Insertion
See Also: Fault Insertion Units
-
Product
CAN/FlexRay/Differential Bus PXI Fault Insertion Switch - 4 Channel
40-200-004
CAN Interface
Each channel can support up to 0.3A and is rated to handle up to 100V between the wire pairs. The wire pairs have controlled transmission line impedance suited to most differential pair signaling systems, including fast CAN Bus interfaces and RS232. Each fault bus is capable of carrying 2A allowing multiple channels to be connected to the same fault condition. Additionally, each fault bus features a changeover relay to allow the user to connect alternative fault conditions to the fault buses.
-
Product
PXI Dual Bus 32-Chan 2A Fault Insert Switch, N/O Through Relays
40-190B-502
Fault Insertion Unit
The Dual Bus, 32 Channel PXI Fault Insertion switch is part of our family of 2 Amp fault insertion solutions, The range includes modules with 74, 64 or 32 channels and single or dual fault buses. This version has normally open through relays, so in the default state, there are no paths between inputs and outputs for any signal channel.
-
Product
Battery Fault Insertion Unit
Fault Insertion Unit
The Battery Fault Insertion Unit (FIU) provides intelligent switching of cell-simulation channels for the Battery Simulator 1200. The switching capability enables simulation of open-circuit and short-to-rail fault conditions on any cell channel for the purposes of battery management system (BMS) testing. Additionally, a four-wire auxiliary input allows you to connect an external digital multimeter (DMM) instrument to any cell channel for very high-accuracy bypass current and cell voltage measurements. Each FIU provides 24 independently-programmable cell-switching channels for one or two 12-cell Battery Simulator 1200 units. Additional Battery Simulator 1200 and FIU instruments can extend functionality up to 120 series-connected cell channels.
-
Product
PXI/PXIe Fault Insertion Switch, 64-Chan 2A, N/C Through Relays, Fault Buses on M & U
40-190C-112
Fault Insertion Unit
The 40-190C-112 (PXI) and 42-190C-112 (PXIe) are fault insertion switches with 64 channels. They are part of a range of modules available with 74, 64 or 32 channels and are primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers.
-
Product
PXI 5A Fault Insertion Switch 20-Chan 2-Bus
40-198-002
Fault Insertion Unit
The 40-198 is a 20 Channel Fault Insertion switch, primarily designed for the simulation of fault conditions in automotive/avionics applications involving the reliability testing of safety critical controllers.
-
Product
PXI Fault Insertion Switch, 7-Channel, One Fault Bus, 20 A, Hardware Interlock
40-193A-001-HI
Fault Insertion Unit
The 40-193A-001-HI is a 7-Channel Fault Insertion switch with hardware interlock and one fault bus, designed for the simulation of fault conditions in automotive systems. The module is capable of switching current up to 20A.
-
Product
PCI Fault Insertion Switch Cards
-
Pickering's PCI Fault/Signal Insertion Switch Cards feature a breakout arrangement that allows faults to be attached to the sensor lines, this includes the breaking of a connection or the adding of defect all of which can simulate connectivity problems in the system.
-
Product
PXI Fault Insertion Switch, 6-Channel, Two Fault Buses, 30 A, Hardware Interlock
40-191B-012-HI
Fault Insertion Unit
The 40-191B-012-HI is a PXI fault insertion switch with hardware interlock using solid state switching elements and is capable of carrying 40A on single channel or 30A on all channels at the same time and provides a robust solution to high current fault insertion.
-
Product
PXI Differential Fault Insertion Switch Modules
-
Pickering's PXI Differential Fault Insertion Switch Modules support multiple channels of two-wire serial interfaces. Each channel can simulate an open fault in either or both wires, a short between both wires or a short to externally applied fault conditions. *Two module types are available: Two wire fault insertion module suitable for CAN Bus and FlexRay.*High bandwidth two wire fault insertion module suitable for Gigabit Ethernet, AFDX and BroadR-Reach.
-
Product
PXI 11-Channel 2A Fault Insert Switch
40-202-101
Fault Insertion Unit
This is the 11 Channel version of the 40-202 Fault Insertion Switch. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers. It is designed to be able to insert three different fault conditions between the test fixture and the equipment under test
-
Product
PXI/PXIe 1000Base-T1 Dual Multiplexer With Fault Insertion, Dual Channel
42-204-002
Multiplexer Module
The 40-204-002 (PXI) and 42-204-002 (PXIe) are dual channel differential multiplexers designed to simulate common faults on high-speed two wire communication interfaces such as 1000Base-T1. They are available with support for 1 or 2-channels of two wire serial interfaces. Each channel pair can be looped out to external equipment or the switches can be used simulate a channel open fault.
-
Product
PXI 10A Fault Insertion Switch 10-Chan 2-Bus
40-199-002
Fault Insertion Unit
The 40-199 is a 10 Channel Fault Insertion switch designed for the simulation of fault conditions in automotive/avionics applications, involving the reliability testing of safety critical controllers.
-
Product
CAN/FlexRay/Differential Bus PXI Fault Insertion Switch - 8 Channel
40-200-008
CAN Interface
This PXI Fault Insertion module is designed to simulate common faults on two wire communication interfaces such as CAN Bus. This module supports 4 or 8-channels of two wire serial interfaces. Each channel can simulate an open fault in either or both wires, a short between both wires or a short to one of eight externally applied fault connections, such as a battery connection or ground, via four fault buses. Each channel can support up to 0.3A and is rated to handle up to 100V between the wire pairs. The wire pairs have controlled transmission line impedance suited to most differential pair signalling systems, including fast CAN Bus interfaces and RS232. Each fault bus is capable of carrying 2A allowing multiple channels to be connected to the same fault condition. Additionally, each fault bus features a changeover relay to allow the user to connect alternative fault conditions to the fault buses.
-
Product
PXI/PXIe 1000Base-T1 Dual Multiplexer With Fault Insertion, Dual Channel
40-204-002
Multiplexer Module
The 40-204-002 (PXI) and 42-204-002 (PXIe) are dual channel differential multiplexers designed to simulate common faults on high-speed two wire communication interfaces such as 1000Base-T1. They are available with support for 1 or 2-channels of two wire serial interfaces. Each channel pair can be looped out to external equipment or the switches can be used simulate a channel open fault. Using the fault bus, switches can simulate a short between both wires or a short to one of two externally applied fault conditions – such as battery supply or ground - via two fault buses.
-
Product
48-Ch 2A-250VAC 2-Bus Fault Insertion
YAV90076
Fault Insertion Unit
48 channels2A 250V 2 Fault Insertion BusesSwitching up to 60CAN Control (or Ethernet with Ethernet to CAN Gateway)Drivers dll & VIs available
-
Product
CAN/FlexRay/Differential Bus PCI Fault Insertion Switch - 8 Channel
50-200-008
Fault Insertion Unit
This PCI Fault Insertion card is designed to simulate common faults on two wire communication interfaces such as CAN Bus. This card supports 4 or 8-channels of two wire serial interfaces. Each channel can simulate an open fault in either or both wires, a short between both wires or a short to one of eight externally applied fault connections, such as a battery connection or ground, via four fault buses.
-
Product
Ethernet/AFDX/BroadR-Reach PXI Fault Insertion Switch - 4 Channel
40-201-004
Fault Insertion Unit
This high bandwidth differential fault insertion module is designed to simulate common faults on high speed two wire communication interfaces such as Ethernet. This module supports 4 or 8-channels of two wire serial connections and can be used for simulating faults on Ethernet, AFDX, BroadR-Reach, 100BaseT and 1000BaseT interfaces. Any wire can be set to an open circuit, shorts can be applied across the wire pair, or to the adjacent pair. Fault connections can be made to one of four external signals via two fault buses, typically simulating connections to a supply voltage or ground. Each fault bus is capable of carrying 2A allowing multiple channels to be connected to the same fault condition. Additionally, each fault bus features a changeover relay to allow the user to connect alternative fault conditions to the fault buses.
-
Product
PXI/PXIe Fault Insertion Switch, 64-Chan 2A, N/C Through Relays, Fault Buses on M & U
42-190C-112
Fault Insertion Unit
The 40-190C-112 (PXI) and 42-190C-112 (PXIe) are fault insertion switches with 64 channels. They are part of a range of modules available with 74, 64 or 32 channels and are primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers.
-
Product
PXI Fault Insertion Switch, 6-channel, Two Fault Buses, 10 A
40-192A-012
Switch Module
The 40-192A-012 is a PXI fault insertion switch using solid state switching elements and is capable of switching current up to 10A. It is designed to be able to insert three different fault conditions between the test fixture and the equipment under test
-
Product
PXI Dual Bus 64-Chan 2A Fault Insertion Switch
40-190B-102
Fault Insertion Unit
The Dual Bus, 64 Channel PXI Fault Insertion switch is part of our family of 2 Amp fault insertion solutions, The range includes modules with 74, 64 or 32 channels and single or dual fault buses. This version has normally closed through relays, so in the default state, there is a path between input and output for all signal channels. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers.
-
Product
PXI Fault Insertion Switch, 7-Channel, Two Fault Buses, 20 A
40-194A-002
Switch Module
The 40-194A-002 is a 7-Channel Fault Insertion switch with two fault buses, designed for the simulation of fault conditions in automotive systems. As well as high current handling of 20A, very low currents can also be switched.
-
Product
Single Bus 36-Channel 2A PCI Fault Insertion Switch
50-190-201
Fault Insertion Unit
This PCI fault insertion switch range is available with 75, 64 or 36 channels. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers. The Stimulus/Measurement to UUT path is suitable for supporting CAN and FlexRay bus systems.
-
Product
PXI Single Bus 74-Ch 2A Fault Insertion Switch, N/O Through Relays
40-190B-301
Fault Insertion Unit
The Single Bus, 74 Channel PXI Fault Insertion switch is part of our family of 2 Amp fault insertion solutions, The range includes modules with 74, 64 or 32 channels and single or dual fault buses. This version has normally open through relays, so in the default state, there are no paths between inputs and outputs for any signal channel. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers.
-
Product
PXI BRIC4 FIBO Matrix Dual 62x4 2pin brkout
40-592A-012
Matrix Switch Module
The 40-592A FIBO (Fault Insertion Break-Out) Matrix Module is a large-scale high density switching matrix based on the Pickering BRIC format. The fault insertion BRICs are designed for applications requiring the simulation of a variety of faults in complex, high pin count, applications involving sensors and control units. Typical faults that can be simulated are open-circuits, short circuits to ground or battery, or short-circuits between input/output lines.
-
Product
PXI Fault Insertion Switch, 7-Channel, One Fault Bus, 20 A
40-194A-001
Fault Insertion Unit
The 40-194A-001 is a 7-Channel PXI Fault Insertion switch with one fault bus, designed for the simulation of fault conditions in automotive systems. As well as high current handling of 20A, very low currents can also be switched.
-
Product
PXI BRIC8 FIBO Matrix Dual 60x4 3pin brkout
40-592A-103
Matrix Switch Module
The 40-592A FIBO (Fault Insertion Break-Out) Matrix Module is a large-scale high density switching matrix based on the Pickering BRIC format. The fault insertion BRICs are designed for applications requiring the simulation of a variety of faults in complex, high pin count, applications involving sensors and control units.
-
Product
PXI Fault Insertion Switch, 7-Channel, Two Fault Buses, 20 A, Hardware Interlock
40-194A-002-HI
Fault Insertion Unit
The 40-194A-002 is a 7-Channel Fault Insertion switch with hardware interlock and two fault buses, designed for the simulation of fault conditions in automotive systems. As well as high current handling of 20A, very low currents can also be switched.
-
Product
PXI 10GBase-T1 Ethernet MEMS Fault Insertion Switch, 8 Channel
40-205-008
Fault Insertion Unit
The 40-205-008 (PXI) is a 8-channel fault insertion switches designed to simulate common faults on high speed two wire communication interfaces such as xBaseT1 Ethernet. They available with 4 or 8 channels of two wire serial connections and can be used for simulating faults on 10BaseT1, 100BaseT1, 1000BaseT1 and 10GBaseT1 Ethernet interfaces. Any wire can be set as open circuit and shorts can be applied across wire pairs. Fault connections can be made to one of four external signals via two fault buses, typically simulating connections to supply voltage or ground.
-
Product
PXI BRIC8 FIBO Matrix Dual 186x4 2pin brkout
40-592A-116
Matrix Switch Module
The 40-592A FIBO (Fault Insertion Break-Out) Matrix Module is a large-scale high density switching matrix based on the Pickering BRIC format. The fault insertion BRICs are designed for applications requiring the simulation of a variety of faults in complex, high pin count, applications involving sensors and control units.
-
Product
Modular Breakout System 78-Pin D-type Plugin Module
95-200-001
-