Impedance Testers
See Also: Loop Impedance Test, Impedance Analyzers
-
Product
Impedance Analyzers
HTF-1100.
-
A laboratory furnace used specifically for the electrical characterization of materials and also for heat treatment between ambient temperature and 1100 °C.
-
Product
Precision Impedance Analyzer
TH2851-130
-
Changzhou Tonghui Electronic Co., Ltd.
■ Test frequency: 10Hz-130MHz ■ High precision: using automatic balance bridge technology, four-terminal pair test configuration ■ High stability and consistency ■ High speed: the fastest test speed up to 5ms
-
Product
Impedance Analyzer
TH2839A
-
Changzhou Tonghui Electronic Co., Ltd.
■ Freq: 20Hz-5MHz, max. resolution 1mHz ■ Test Accuracy: 0.05% ■ Test Speed: Max.7.7ms ■ Auto-balance bridge technology, 4-terminal pair ■ High stability and consistency: up to 15 test ranges
-
Product
Line Impedance
KIT
-
The Line impedance kit is composed of two modules, STLG and STSG. The kit is meant to be used with STS 5000, STS 4000 and eKAM in order to perform Line Impedance test.
-
Product
Impedance Stabilization Network
-
Beijing KeHuan Century EMC Technology Co,.LTD
KH8158 is a device for measuring the common mode interference voltage of unshielded twisted pair cables. Cable testing according to CISPR 16-1-2. The equipment under test (EuT) and auxiliary equipment (AE) are directly connected to the corresponding ports. The port adopts RJ-45 socket (the distribution conforms to T568A/B.) This equipment is divided into three specifications: CAT3, CAT5, and CAT6, and the corresponding equipment is selected according to the cable model.
-
Product
High Impedance Probes
-
Everbeing offers GGB’s high impedance active probe for failure analysis of your devices. The high impedance with low capacitive design allows measurements of internal nodes without loading the device. For more information, please visit http://www.ggb.com.Everbeing offers GGB’s high impedance active probe for failure analysis of your devices. The high impedance with low capacitive design allows measurements of internal nodes without loading the device. For more information, please visit http://www.ggb.com.
-
Product
Precision Impedance Analyzer
TH2851-080
-
Changzhou Tonghui Electronic Co., Ltd.
■ Test frequency: 10Hz-80MHz ■ High precision: using automatic balance bridge technology, four-terminal pair test configuration
-
Product
Impedance Analyzer 1MHz-20Hz
IA1000
-
Frequency range20 ~ 1MHzFrequency accuracy0.005%Frequency resolution0.001% in all frequency rangeTest signal level0.05 ~ 2.0 VrmsTest signal resolution0.001 VrmsTest signal output impedance100ΩImpedance Z range; basic accuracy0.0000Ω ~ 99.99
-
Product
Antenna Impedance Analyzer
TZ-900 AntennaSmith
-
Analysis Parameters: SWR, Complex Impedance, R+jX, reflection coefficient, Smith Chart. 0.2 - 55 MHz • SWR
-
Product
Impedance Spectroscopy
NuVant EZware-EIS Software Package
-
The NuVant EZware-EIS software package activates Electrochemical Impedance Spectroscopy on the EZstat-Pro, Powerstat-05 and -20 potentiostat/galvanostats. EZware-EIS exports the impedance data to a file format to accommodate free third party EIS analysis software. EZware-EIS is a user-friendly interface that allows selection of the proper scanning parameters, collect the impedance spectra, display data in Nyquist and/or Bode plots and export data in the proper data format for use in EIS analysis software.
-
Product
Impedance Analyzer
MFIA
-
The Zurich Instruments MFIA is a digital impedance analyzer and precision LCR meter that sets the new standard for impedance measurements in the frequency range from DC to 5 MHz. The MFIA provides 0.05% basic accuracy and a measurement range spanning from 1 m to 10 G. The instrument has a high measurement repeatability and a small temperature drift. With the LabOne user interface the MFIA offers a number of long-awaited innovations for the impedance and LCR measurement available without the need of any software installation.
-
Product
FC Impedance Meters
-
designed for testing of the fuel cell with the small current (5 A or less), and not only the current-voltage characteristic test, the KFM2005 can easily measure for the impedance of a fuel cell using the AC impedance method, and the Cole-Cole plot. Using the measurement data of the Cole-cole plot, it is possible to calculate the circuit constant of the approximate equivalent circuit of the fuel cell. The built-in DC load (60W) is capable to operate from 0 V, and it can perform the test for the fuel cell up to 20V and 5A.
-
Product
High Impedance Active Probes
7A
-
An unterminated version, can be used for capacitance and resistance measurements or in low to medium speed signal applications where a 50 ohm termination is not required. A flexible coaxial cable length of 6 feet in length is standard on the Model 7A; however, when used for capacitance measurements, GGB Industries, Inc., recommends using a shorter 3 foot cable. If a shorter length of cable is desired for capacitance measurements, please specify it when ordering (Model 7A-3ft.). Please note that Model 7A uses Model 7 replacement tips.
-
Product
Nodal Impedance Analyser
QT-Hi1
-
Qmax Test Technologies Pvt. Ltd.
QT-Hi1 is an innovative Nodal Impedance Analyzer, which uses the industry’s proven V-I trace techniques of learn and compare of nodal impedances which are represented as VI Curves. It uses innovative Auto Best Curve fit technique an intelligent software alogorithm which enables automatic selection of the best fit value of Voltage, Source Impedance and Frequency of the stimulus waveform. The compact size with re-chargeable battery makes it an ideal companion for on-field applications. The wide 8” touch screen graphical display makes this tool more valuable in test and repair industry at all times.
-
Product
High Impedance Differential Relay
-
High impedance protection schemes are widely used for the protection of BUS bars, generators, motors & power transformers. BUS bar protection schemes utilizing electromechanical high impedance differential relays are often used due to their simplicity, reliability & comparatively low cost.
-
Product
Short Circuit Loop Impedance Meter
AMZC-304
-
Short circuit loop impedance measurement in networks with nominal voltage: 220/380V, 230/400V, 240/415V, with frequency 45…65Hz ; Short circuit loop impedance measurement with 15mA current, without triggering RCD. ; Detection of the replacement L and N in the socket and automatic swap in the meter
-
Product
Precision Impedance Analyzer
TH2851-050
-
Changzhou Tonghui Electronic Co., Ltd.
■ Test frequency: 10Hz-50MHz ■ High precision: using automatic balance bridge technology, four-terminal pair test configuration
-
Product
RF Impedance Transformers
-
Are designed and optimized to best deliver power into an impedance of 50 Ohms.
-
Product
FC(Fuel Cell) Impedance Measurement System
KFM2150 System
-
The KFM2150 system is a fuel cell impedance measurement system configured with an FC impedance meter KFM2150 and an electronic load PLZ-4W series. Combination of KFM2150 and PLZ-4WA series (0V input type) supports impedance measurement for single cell of fuel cell.In addition to impedance measurement with AC impedance method, KFM2150 system provides IR measurement with current interrupt method.Application software enables test for each characteristic of fuel cell such as I-V characteristics, Constant Current characteristics, Current Interrupt method and Cole-Cole plot by the AC impedance method. Moreover, each test can be performed in a specified order.
-
Product
High Impedance Busbar Differential Relay
MIB
-
The MIB, a member of the M II family of economical and highly functional digital protection relays, is a microprocessor based relay that provides three phase high impedance differential protection for Substation Bus-bars of any voltage level. Use the MIB also to protect electrical machines like transformers, generators or motors against restricted earth faults.
-
Product
High Impedance Active Probes
28 AND 29
-
Designed to serve the needs of integrated circuit engineers working in the most advanced high speed, submicron, MOS technology. These high frequency instruments include the attractive features of the Models 18C and 19 including full dc capability, negligible dc current drain, and extremely low input capacitance. In addition the frequency range of the Models 28 and 29 has been extended to a full 1 GHz.
-
Product
High Impedance Active Probes
12C
-
A high speed, high input impedance active probe for measuring the internal node voltage of integrated circuits. The input is 1 megohm shunted by 0.1 pf and the rise/fall times are 0.8 ns. This instrument has full dc capability and can be used with any oscilloscope. The Model 12C was specially designed so that when used in conjunction with a high input impedance oscilloscope, signal attenuation is 10:1 and with a 50 Ohm input, signal attenuation is 20:1.
-
Product
Controlled Impedance Field Solver
Si8000m
-
TheSi8000m is an all new boundary element method field solver , which builds on the familiar easy to use user interface in earlier Polar impedance design systems. The Si8000m adds enhanced modeling to predict the finished impedance of multiple dielectric PCB builds and also takes into account the local variations in dielectric constant on close spaced differential structures.
-
Product
Impedance Standards and Calibrators
-
Impedance Calibrator is to replace countless single value RCL standards with one calibrator that can switch between the standards like a CD changer in your car. The calibrator contains stable and temperature independent resistance standards, partial capacitance standards and partial inductance standards, simulated by RC T-type passive network. Calibration values of both complex parameters of partial standards are displayed on large LCD screen in preselected pairs of parameters as well as voltage, current and frequency readouts from built-in test signal meter. OPEN and SHORT reference positions are available as well.
-
Product
Impedance Analyzer
1260A
-
The model 1260A Impedance/Gain-Phase Analyzer is - without doubt - the most powerful, accurate and flexible Frequency Response Analyzer available today. In daily use by leading researchers wherever measurement integrity and experimental reliability are of paramount importance, the 1260A’s solid reputation is frequently endorsed in published research papers in fields.
-
Product
High Impedance Active Probes
7
-
Designed as a companion probe to Models 12C and 18C for driving integrated circuit lines so the Model 12C and 18C can be used to measure the response of adjacent nodes. The Model 7 consists of a flexible 6 foot, 50 ohm coaxial cable accurately terminated to 50 ohms in order to avoid undesirable reflections. A special miniature connector receives replacement coaxial probe tips that provide a shielded environment to within 3 mm of the fine tungsten probe point, thus minimizing capacitive coupling to other parts of the circuit. The replaceable coaxial probe tips are offered in various point sizes and can also be bent to any shape in order to accommodate a variety of probing geometries.
-
Product
Impedance Analyzers
-
A/D converted input signals undergo discrete Fourier transform (DFT) to calculate complex impedance values and obtain parameters and characteristics specific to the DUT, such as its capacitance, inductance and quality factor. Original NF algorithms are also applied to allow equivalent circuits made up of R, L and C along with the constants for those circuits to be estimated from the complex impedance spectrum obtained by sweeping the frequencies.