General Purpose Switch
is an array of uncommitted relays. Also known as: General Purpose Switching
See Also: Switching, Switching Matrix, High Voltage Switching, Switching Matrices, Multiplexers
-
product
P2665 General Purpose Probes
Current Rating (Amps): 15Average DC Resistance lower than (mOhm): 10Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 230Full Travel (mm): 5.84Recommended Travel (mil): 167Recommended Travel (mm): 4.24Overall Length (mil): 1,290Overall Length (mm): 32.77Overall Length Remark: Tip 2W: 1270 mil (32.26 mm)
-
product
Switch Modules - 16 Single Pole, Form A, Discrete Relays Which are Wired & Controlled Individually
JX16/KA
This module has 16 single pole, Form A, discrete relays which are wired and controlled individually. The relays can be externally wired to make any configuration needed. Use as individual ON/OFF relays or use them to drive external relays, solinoids, or any external device. It is available with Type S or M reed relays.
-
product
Standard 1.55 (44.00) - 3.20 (91.00) General Purpose Probe
HPA-50U
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 50Full Travel (mm): 1.27Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 590Overall Length (mm): 14.99
-
product
PXI Dual 2 Channel (M Mode) SC 50 Cons
40-855-222-M50
The fiber optic switches connect the common to a channelby redirecting the optical signal into a selected output fiber.This is achieved using Micro-Mechanical Mirrors driven bya highly precise mechanism and activated via an electricalcontrol signal.
-
product
High 4.00 (113.00) - 6.70 (190.00) General Purpose Probe
P2550-0-8
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 30Test Center (mil): 187Test Center (mm): 4.75Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Overall Length (mil): 1,453Overall Length (mm): 36.91Rec. Mounting Hole Size (mil): 126Rec. Mounting Hole Size (mm): 3.20Recommended Drill Size: #30 or 3.20 mm
-
product
Cup Reduced Concave, Standard 0.61 (17.00) - 2.80 (79.00) General Purpose Probe
HPA-0G12
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 635Overall Length (mm): 16.13
-
product
PXI/PXIe Microwave Transfer Switch, Single, 18 GHz, 50 Ω, SMA, Failsafe
42-782B-521
The 40-782B-521 (PXI) and 42-782B-521 (PXIe) single failsafe transfer switches are part of our range of PXI microwave switching modules. They have a characteristic impedance of 50 Ω and a maximum operating frequency of 18 GHz. Connections are made via front panel mounted high quality SMA coaxial connectors.
-
product
PXI Hex SPDT RF Switch SMB 75 Ohm
40-830-006
The 40-830-006 is a 75Ω RF Switch 6 separate SPDT relays in a single PXI slot. It has been designed to exhibit low insertion loss and VSWR through the use of modern RF relay technology at an affordable cost. The switch banks have been carefully designed to ensure excellent and repeatable RF characteristics to frequencies of 3GHz with each path having a nominally equal insertion loss.
-
product
PXI Single Microwave Transfer Switch 18GHz 50 SMA
40-782A-521
The 40-782A-521 is a single transfer switch and is part of our range of PXI microwave switching modules. It has a characteristic impedance of 50Ω and a maximum operating frequency of 18GHz. Connections are made via front panel mounted high quality SMA coaxial connectors.
-
product
Alternate 1.10 (31.18) - 7.20 (204.00) Switch Probe
TSP100-H180-2
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 20Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 197Full Travel (mm): 5.00Recommended Travel (mil): 157Recommended Travel (mm): 4.00Overall Length (mil): 1,990Overall Length (mm): 50.60Switch Point (mil): 59Switch Point (mm): 1.50
-
product
Standard 0.50 (14.00) - 2.00 (57.00) Non Replaceable General Purpose Probe
A-A-S-C
Current Rating (Amps): 2Average DC Resistance lower than (mOhm): 30Test Center (mil): 39Test Center (mm): 1.00Full Travel (mil): 30Full Travel (mm): 0.76Recommended Travel (mil): 20Recommended Travel (mm): 0.51Overall Length (mil): 310Overall Length (mm): 7.87Rec. Mounting Hole Size (mil): 31.5Rec. Mounting Hole Size (mm): 0.80Recommended Drill Size: #68 or 0.79 mm
-
product
Alternate 3.50 (99.00) - 6.85 (194.00) General Purpose Probe
P2757G-1R2S
Current Rating (Amps): 20Average DC Resistance lower than (mOhm): 10Test Center (mil): 187Test Center (mm): 4.75Full Travel (mil): 230Full Travel (mm): 5.84Recommended Travel (mil): 167Recommended Travel (mm): 4.24Overall Length (mil): 1,210Overall Length (mm): 30.73Overall Length Remark: Tip 2C: 1140 mil (28.96 mm) Tip 1W: 1205 mil (30.61 mm) Tip 2W: 1205 mil (30.61 mm)
-
product
Non-Replaceable General Purpose Probe - Epoxy Mount
MEPJ-22BD
Current Rating (Amps): 2Average Probe Resistance (mOhm): 125Test Center (mil): 20Test Center (mm): 0.51Full Travel (mil): 79Full Travel (mm): 2.01Recommended Travel (mil): 52Recommended Travel (mm): 1.33Mechanical Life (no of cyles): 50,000Overall Length (mil): 810Overall Length (mm): 20.60Rec. Mounting Hole Size (mil): 13.8Rec. Mounting Hole Size (mm): 0.35Rec. Mounting Hole Remark: 13.5 to 14mil / 0.34 to 0.36 mmRecommended Drill Size: #80 or 0.35 mm
-
product
Ultra High Density Matrix Switch Card
1260-45
The Astronics 1260-45 offers the highest-density switching matrices in a single-slot C-size VXI module, configurable as 11 different matrices from four 4x16 2-Wire to one 16x16 two-wire. Easily extend this module externally to build a larger matrix in a single VXI chassis to satisfy even the most dense applications.
-
product
Ultra High 4.18 (119.00) 11.70 (332.00) General Purpose Probe
EPA-3J-2
Current Rating (Amps): 6Average Probe Resistance (mOhm): 35Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
PXI/PXIe Microwave Transfer Switch, Dual, 40 GHz, 50 Ω, SMA-2.9, Failsafe, Remote Mount
42-782B-542-E
The 40-782B-542-E (PXI) and 42-782B-542-E (PXIe) dual failsafe transfer switches with remotely mounted relays are part of our range of PXI microwave switching modules. They have a characteristic impedance of 50 Ω and a maximum operating frequency of 40 GHz. Connections are made via front panel mounted high quality SMA-2.9 coaxial connectors.
-
product
Standard 2.00 (57.00) - 3.60 (102.00) General Purpose Probe
P2664G-4V1S
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 10Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 114Full Travel (mm): 2.90Recommended Travel (mil): 84Recommended Travel (mm): 2.13Overall Length (mil): 895Overall Length (mm): 22.73Overall Length Remark: Tip 1C: 845 mil (21.46 mm) Tip 2R: 935 mil (23.75 mm)
-
product
PXI Triple SPDT RF Switch 3GHz 50 SMB
40-870-003
The 40-870 is a 50 RF Switch available with 3 or 6 separate SPDT relays in a single PXI slot. Both versions exhibit low insertion loss and VSWR through the use of modern RF relay technology at an affordable cost. The switch banks been carefully designed to ensure excellent and repeatable RF characteristics to frequencies of 3GHz. The injection of noise and unwanted signals into the signal paths of the 40-870 has been minimized by careful attention to the mechanical and electrical design.
-
product
Standard 0.70 (2.00) - 1.70 (4.80) General Purpose Probe
P2662AG-2V1S
Current Rating (Amps): 3Average DC Resistance lower than (mOhm): 30Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 90Full Travel (mm): 2.29Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 710Overall Length (mm): 18.03
-
product
Alternate 1.10 (31.18) - 7.20 (204.00) Switch Probe
TSP100-H150-2
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 20Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 197Full Travel (mm): 5.00Recommended Travel (mil): 157Recommended Travel (mm): 4.00Overall Length (mil): 1,990Overall Length (mm): 50.60Switch Point (mil): 59Switch Point (mm): 1.50
-
product
PXI 10A Fault Insertion Switch 6-chan 2-bus
40-192-012
This PXI fault insertion switch uses solid state switching elements and is capable of switching current up to 10A. It is designed to be able to insert three different fault conditions between the test fixture and the equipment under test: Open-Circuit. Short-Circuit between UUT connections. Short-Circuit to external signals. Through relays on each channel enable signals to the UUT to be set open-circuit. Fault Insertion Buses allow any channel to be shorted to any other channel and also enable any channel to be connected to an external signal such as Power, Ignition or Ground to simulate fault conditions. The module is supplied with 2 fault buses.
-
product
PXI Solid-State Switch Module, 6xSPST, 25 A, 100 V, Hardware Interlock
40-184A-001-HI
The 40-184A-001-HI has 6-off high current SPST switches with hardware interlock in two PXI slots and is part of our range of high power solid state switching solutions.
-
product
PXI/PXIe MEMS Optical Switch, Triple Insert/Bypass
40-860A-332
The 40/42-860A-332 is a PXI/PXIe triple insert/bypass switch with MU connectors and is part of Pickering's range of PXI Fiber Optic MEMS Switching modules. They are available in many high density formats with a choice of different connector styles to suit most applications: FC/APC (for optimal performance), FC/PC and SC/PC for general applications and LC and MU for high density applications. They are also available with an optional hardware interlock which, when activated, will return all optical switches to their default unpowered state.
-
product
Ultra High 12.90 (366.00) - 48.00 (1361.00) General Purpose Probe
EPA-5H-2
Current Rating (Amps): 8Average Probe Resistance (mOhm): 35Test Center (mil): 187Test Center (mm): 4.75Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,420Overall Length (mm): 36.07
-
product
Alternate 1.30 (37.00) - 4.50 (128.00) General Purpose Probe
HPA-1T-1
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 655Overall Length (mm): 16.64
-
product
PXI/PXIe MEMS Optical Switch, Triple Insert/Bypass, Single-Mode, 9/125 Fiber, LC Connectors
42-860A-432
The 40/42-860A-432 is a PXI/PXIe triple insert/bypass switch with LC connectors and is part of Pickering's range of PXI Fiber Optic MEMS Switching modules.
-
product
Standard 1.08 (31.00) - 3.50 (99.00) General Purpose Probe
EPA-2P
Current Rating (Amps): 5Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 160Full Travel (mm): 4.06Recommended Travel (mil): 107Recommended Travel (mm): 2.72Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 970Overall Length (mm): 24.64
-
product
Crown, Four Point, Alternate 0.78 (22.00) - 3.70 (105.00) General Purpose Probe
HPA-0L-1
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 635Overall Length (mm): 16.13
-
product
MXG X-Series Microwave Analog Signal Generator, 9 kHz to 40 GHz
N5183B
Get a fast, compact (2U) alternative to the PSG in the lab, depot or fieldAddress demanding tests of radar modules & systems with near-PSG levels of spectral purityCompensate for system loss & drive high-power amplifiers: +19 dBm output power, -55 dBc harmonics & -68 dBc spurious @ 20 GHzReduce calibration time with switching speed 600 sSimulate narrowband chirps & radar antenna scans with up to five internal function generators that can be used with AM, FM, OM pulse modulation
-
product
AT-1120, 14-Bit, 2 GS/s, 2-Channel Signal Generator Adapter Module for FlexRIO
782248-01
The AT-1120 provides simultaneously sampled analog output channels for signal generation. It also features single-ended, DC-coupled inputs. The AT-1120 is ideal for generating complex signals like digital modulations and RF stimuli for functional and performance tests. Each channel has a user-configurable sample rate, and data is written directly from the FPGA. To use the AT-1120, you must pair it with a compatible PXI FPGA Module for FlexRIO.