LED Sources
emit light as a reference or to illuminate.
See Also: Light Sources, Optical Light Sources
-
Product
Source Measure Units (SMUs)
B1511B
Source Measure Unit
The SMUs of B1500A integrate 4-quadrant voltage/current source and measurement capabilities for accurate IV measurement with the range of 0.1 fA - 1 A / 0.5 µV - 200 V. It supports spot, sweep, pulse sampling and QS-CV measurements.
-
Product
PXIe Precision Source/Measure Unit, 1.25 MSa/s, 10 fA, 210 V, 315 mA
M9601A
Source Measure Unit
M9601A PXIe precision SMU is the industry-first precision PXIe SMU enabling faster precise measurement from DC to 20 μs pulse up to 210 V/315 mA with the best-in-class 10 fA resolution and low noise.
-
Product
S2 Unicolor Sensors
ULP-S2 SCI/V
LED Sensor
The Universal LightProbe S2 Unicolor Sensor is designed for the intensity test of any single one of the five main LED colors (blue, green, yellow, orange, and red) plus white and Infrared (700nm to 1,000nm). Implemented in a unique and customizable 2-Part solution, the S2 Unicolor Sensor is assembled with your choice of Fiber-Optic Probe, including for the test of densely-spaced LEDs, bright LEDs, dim or misaligned LEDs, right-angle LEDs, and more, including the popular “Trident” Fiber-Optic Probes to sequentially test 3 LEDs with a single Sensor.Operating temperature range: 0oC to 70oCPower consumption: Operates between +5 and 28 volts D.C., at 6mA max. Less than 4.75 volts is not recommendedVoltage protection: Withstands up to +40 volts, & reverse polarity to -18 voltsSignal Output Loads: 20 mA max. Non-inductive.Output Pins: 3 gold-plated standard wire-wrap pins (0.025 in. sq.)Sensor Size: 0.560 in. dia x 1.38 in. longOperating Temperature Range: 0hC to 70hCTypical response times:<10mS capture time; 65mS overall response time; intensity output of correct color only.Fiber-Optic Probes: Can utilize any Universal LightProbe Fiber-Optic Probe
-
Product
Fixed Wavelength CW Laser Source (DFB)
Laser 1200 Series
Laser Source
The Laser 1200 Series is a highly customizable fixed-wavelength Continuous Wave (CW) laser source available in a wide range of wavelengths and powers.With seamless PXI integration, it can be easily integrated into new or existing PXI test setups. Save space, lower your costs and improve testing efficiency while delivering reliable and repeatable results in production or research environments.
-
Product
Optical Switches
Optical Source
Fast and reliable optical switches to streamline your test procedures. Can be customized with a wide range of switch configurations, fiber types and connectors.
-
Product
Step-Tunable Laser Source, High Power and Low SSE, Basic Line
N7779C
Laser Source
The new N7779C basic line step-tunable laser source is ideal for cost-effective testing of broadband optical devices. It can also serve as a highly stable, tunable local oscillator for receiver testing or transmission experiments.
-
Product
PXI Source Measurement Unit
PX773x
Source Measure Unit
The PX773x is a high precision, high speed source and measurement unit, which is designed for automated high throughput testing.
-
Product
PXIe Precision Source/Measure Unit, 15 MSa/s, 100 FA, 60 V, 3.5 A DC/10.5 A Pulse
M9603A
Source Measure Unit
The Keysight M9603A is a PXIe precision SMU featuring best-in-their-class narrow pulse width as narrow as 10 μs. It enables dynamic/pulsed measurements with up to 15 MSa/s for broad emerging applications such as VCSEL optical devices.
-
Product
Fixed Wavelength CW Laser Source (FP) - PXI
Laser 1100 Series
Laser Source
The Laser-1102 is a Continuous Wave (CW) laser source offering high power 850 nm output into multimode fiber with stable output power operation.
-
Product
PXI Isolated Single Channel Voltage/Current Source, 100V
M9186A
Source Measure Unit
The V/I source lets you source a voltage and measure the resultant current, or source a current and measure the resultant voltage. It consist of two separate amplifiers, denoted "low" and "high" that share a common output connection. The "low" amplifier provides voltages in the range of 16 volts at up to 200ma and the "high" amplifier provides voltages in the range of 100V at up to 20mA.
-
Product
S2 Spectra USB Sensors
ULP S2 SPECTRA USB
LED Sensor
Universal LightProbe S2 Spectra USB Sensors test a wide range of LED intensities and any color in the visual spectrum, plus white, providing a linear response with a serial digital output via a PC. A standard USB Cable is provided to connect to a mini-type B five-pin USB connector, which is integrated into the S2 Spectra USB Sensor.Operating temperature range: 0oC to 70oCOutput Port: A standard mini-type B five-pin USB connector is integrated into the S2 Spectra USB Sensor,and a standard USB Cable is provided to connect to a USB portSensor Size: 0.560 in. dia x 1.38 in. long.Typical response time: < 10mS for color and intensity as a serial bit- stream (19200 baud rate)Fiber-Optic Probes: Can be paired with any of a wide range Universal LightProbe Fiber-Optic Probes
-
Product
PXIe-4139, ±60 V, ±3 A DC, ±10 A Pulsed, 20 W DC, 100 fA Precision System PXI Source Measure Unit
782856-02
Source Measure Unit
PXIe, ±60 V, ±3 A DC, ±10 A Pulsed, 20 W DC, 100 fA Precision System PXI Source Measure Unit - The PXIe-4139 is a high-precision, system source measure unit (SMU) that features 4-quadrant operation and sources up to 20 W of DC power. This module features analog-to-digital … converters that help you perform high-precision measurements with a current resolution of 100 fA or high-speed acquisitions up to 1.8 MS/s. The module can maximize stability and measurement accuracy with SourceAdapt technology, which you can use to tune the transient response to match the characteristics of any load. You can use the PXIe-4139 for applications including manufacturing test, board-level test, and lab characterization with devices such as ICs, power management ICs (PMICs), and RFICs and discrete devices including LEDs and optical transceivers.
-
Product
PXIe 5-channel Precision Source/Measure Unit, 500 kSa/s, 10 pA, 30 V, 500 mA
M9615A
Source Measure Unit
The Keysight M9615A is a PXIe five-channel precision source / measure unit (SMU). It supports accurate measurement up to 30 V / 500 mA with resolution down to 6 uV / 10 pA.
-
Product
PXIe-4135, ±200 V, ±1 A DC, ±3 A Pulsed, Up to 40 W DC, 10 fA Precision System PXI Source Measure Unit
783762-01
Source Measure Unit
PXIe, ±200 V, ±1 A DC, ±3 A Pulsed, Up to 40 W DC, 10 fA Precision System PXI Source Measure Unit - The PXIe-4135 is a high-precision, system source measure unit (SMU). It features 4-quadrant operation and sources up to 40 W of DC power and can pulse up to 500 W. Analog-to-digital converter technology and native triaxial connectors help you perform high-precision measurements with a current resolution of 10 fA or high-speed acquisitions up to 1.8 MS/s. The module also can maximize stability and measurement accuracy with SourceAdapt technology, which you can use to tune the transient response to match the characteristics of any load. The PXIe-4135 is ideal for a broad range of applications including manufacturing test, board-level test, and lab characterization with devices such as ICs, power management ICs (PMICs), and RFICs and discrete devices including LEDs and optical transceivers.
-
Product
Source Measurement Unit
PEMU4
Source Measure Unit
The PEMU4 represents a new level of performance and capabilities for USB-based SMU (Source MeasurementUnit) instrumentation. The PEMU4 supports -1V to +6.5V 0.5A with FVMI, FVMV, FIMV, FIMI modes. 4 channel can be ganged to support high current driving. I2C/SPI/RFFE function for serial port device testing. 4 Counter for frequency measurement.
-
Product
S2 Blinx Digital Sensors
ULP-S2 BLINX
LED Sensor
The Universal LightProbe S2 Blinx Digital is designed for the simple ON/OFF test of any color blinking or steady-state LED, for fast results with a digital output. The Universal LightProbe S2 Blinx Digital Sensors check the ON/OFF status of any color LED, whether stable or blinking/pulsed, up to a rate of 15 Hz, and provide a Logic “1” output (5 volts) only if the LED is “ON” and a Logic “0” if the LED is “OFF.”Operating temperature range: 0oC to 70oCPower consumption: Operates from +5, 12, 24 or 28 volts D.C., at 6mA max.Voltage protection: Withstands up to +40 volts, & reverse polarity to -18 voltsSignal Output Load: 20mA max. (Source/Sink). Non-inductiveOutput Pins: 3 gold-plated standard wire-wrap pins (0.025 in. sq.)Sensor Size: 0.560 in. dia x 1.38 in. longOperating Temperature Range: 0hC to 70hCTypical response times: <66mS, shorter for brighter LEDsFiber-Optic Probes: Wide Aperture Fiber-Optic Probe recomended
-
Product
Source/Measure Unit for Battery Drain Analysis, Multiple Ranges, 80 W, Double-wide
N6785A
Source Measure Unit
The N6785A is a source/measure unit (SMU) designed specifically for battery drain analysis of large mobile, battery-powered devices up to 20 V, up to 8 A, up to 80 W.
-
Product
Source Measurement Unit
SMU32
Source Measure Unit
The SMU32 is a low cost solution for V/I source and measurement. The SMU32 offers PMU/DPS in a compact, 3U PXI form factor. The SMU32 supports -1V to +10V +- 32 mA FVMI/FIMV modes. 8~32 PMUs can be ganged to DPS for high current driving.
-
Product
PXIe-4143, 4-Channel, ±24 V, 150 mA Precision PXI Source Measure Unit
782431-01
Source Measure Unit
PXIe, 4-Channel, ±24 V, 150 mA Precision PXI Source Measure Unit - The PXIe-4143 is a 4-channel source measure unit (SMU) ideal for high-pin-count applications. It features 4-quadrant operation and each channel has integrated remote (4-wire) sensing for accurate measurements. The fast sample rate of the PXIe-4143 can reduce measurement times, capture transient device characteristics, and allow quick I V characterization of devices under test (DUTs). With a high-speed sequencing engine, you can synchronize all these SMUs with each other or with other instruments such as switches or high-speed digital test modules. Additionally, you can tune the PXIe-4143 response to any load to achieve optimum responses with maximum stability and minimum transients using SourceAdapt technology.
-
Product
High-Speed Precision SMU (100 FA, 60 V, 1 MSa/s)
PZ2120A
Source Measure Unit
The Keysight PZ2120A is a cost-effective, high-speed precision source / measure unit (SMU) featuring best-in-class narrow pulse width, fast Digitizer Mode, and seamless current measurement ranging. It enables narrow-pulsed measurements and fast dynamic measurements with a wide dynamic range for a wide range of emerging applications such as vertical-cavity surface-emitting laser (VCSEL) optical devices and integrated circuit (IC) testing. In addition, its low measurement noise performance enables measurements with shorter aperture times, and its seamless current measurement ranging function enables a wide dynamic range and eliminates range change time, which improves test throughput.
-
Product
PXIe 5-channel Source/Measure Unit, 500 kSa/s, 100 pA, 30 V, 500 mA
M9614A
Source Measure Unit
The Keysight M9614A is a PXIe five-channel source / measure unit (SMU). It supports accurate measurement up to 30 V / 500 mA with resolution down to 6 μV / 100 pA.
-
Product
Single-Port Tunable Laser System Source
N7711A
Laser Source
The Keysight N7711A and N7714A tunable lasers are single-port and four-port sources, available with C-band or L-band wavelength coverage. The narrow linewidth and offset grid fine-tuning capability make them ideal sources for realistic loading of the latest transmission systems. All models can reach any wavelength point within their specified wavelength range just like all other Keysight tunable lasers. In this mode, code compatibility with existing test setups based on Keysight's range of full-size and compact tunable lasers is a great asset. In system loading applications, it may be preferable to grid-tune the lasers like system transmitters, simply by changing the channel index. The channel grid is adjustable to standard ITU-T grid spacing like 50 GHz, and to arbitrary grids. Likewise, the zero frequency (base channel) of the chosen grid is adjustable. A 12 GHz fine-tuning range allows de-tuning the frequency.
-
Product
4-Quadrant General-Purpose Source/Measure Unit, ±20 V, ±1 A Or ±6 V, ±3 A, 20 W
N6784A
Source Measure Unit
The Keysight N6784A is a source/measure unit (SMU) designed for general-purpose precision sourcing and measurement. General-purpose applications can span many different industries and many different devices under test (DUTs). The N6784A SMU is a versatile tool designed to tackle many of these general-purpose applications. Its glitch-free operation ensures safe usage with the DUT during output and measurement range changes, even with capacitances of up to 150 µF. Its 4-quadrant operation enables it to act as a bipolar power supply or a bipolar electronic load, for added versatility. When using the N6784A SMU, engineers can be confident that they have an all-around general-purpose tool for their test systems or lab bench.
-
Product
Precision Source / Measure Unit (2 Ch, 100 FA)
B2902B
Source Measure Unit
The Keysight B2902B precision source / measure unit (SMU) is a 2-channel, compact, and cost-effective benchtop SMU with the capability to source and measure both voltage and current. It easily measures current versus voltage (I/V) with high accuracy. The 4-quadrant source and measurement capabilities enable taking I/V measurements without configuring multiple instruments.
-
Product
PXIe Source/Measure Unit, 15 MSa/s, 1 PA, 60 V, 3.5 A DC/10.5 A Pulse
M9602A
Source Measure Unit
The Keysight M9602A is a PXIe SMU featuring best-in-their-class narrow pulse width as narrow as 10 μs. It enables dynamic/pulsed measurements with up to 15 MSa/s for broad emerging applications such as VCSEL optical devices.
-
Product
PXIe High-Speed Source/Measure Unit, 13 V, ± 1 A or 6 V, ± 3 A, 18 W
M9111A
Source Measure Unit
The M9111A is a 1-slot, 2-quadrant PXIe module that provides stable, glitch-free sourcing and sinking, and high accuracy measurements. It offers high-throughput and measurement quality for design validation and production test of RF power amplifiers. With industry-leading output stability under extreme, dynamic load conditions and unmatched transient performance to dramatically reduce voltage droop due to pulse loading, the M9111A SMU speeds test time. The high-speed M9111A can change its output voltage, stabilize that voltage, and accurately measure current from Amps down to micro-Amps all in less than 1 ms so that you can move on to the next test as quickly as possible.
-
Product
High Precision Source Measure Unit (SMU) - Hybrid Compatible PXI, 100ks/S Programming/Measurement Speed
52400 series
Source Measure Unit
Hybrid Compatible PXIFour quadrant operationHigh source/measurement resolution (multiple ranges)Low output noiseHigh programming/measurement speed (100k s/S) & slew rateOptional measurement logDIO bitsOutput profiling by hardware sequencerProgrammable output resistanceFloating & Guarding output16 Control Bandwidth SelectionMaster / Slave operationDriver with LabView/LabWindows & C/C# APISoftpanel GUI
-
Product
Source Measure Units and LCR Meters
Source Measure Unit
Source Measure Units are high-precision, high-accuracy DC instruments that can both source and simultaneously measure voltage and current. Additionally, LCR Meters can measure the inductance, capacitance, and resistance (LCR) of electronic equipment.
-
Product
Four-Port Tunable Laser System Source
N7714A
Laser Source
The Keysight N7711A and N7714A tunable lasers are single-port and four-port sources, available with C-band or L-band wavelength coverage. The narrow linewidth and offset grid fine-tuning capability make them ideal sources for realistic loading of the latest transmission systems. All models can reach any wavelength point within their specified wavelength range just like all other Keysight tunable lasers. In this mode, code compatibility with existing test setups based on Keysight's range of full-size and compact tunable lasers is a great asset. In system loading applications, it may be preferable to grid-tune the lasers like system transmitters, simply by changing the channel index. The channel grid is adjustable to standard ITU-T grid spacing like 50 GHz, and to arbitrary grids. Likewise, the zero frequency (base channel) of the chosen grid is adjustable. A 12 GHz fine-tuning range allows de-tuning the frequency.
-
Product
USB Modular Source Measure Unit
U2723A
Source Measure Unit
The 3-channel 20V/120mA module can operate in a 4-quadrant operation. The channels could be connected in series or in parallel to achieve up to 60 V/360 mA. It uses the common non-proprietary standard high-speed USB 2.0 interface that provides ease of connectivity allowing users to set up and configure their tests swiftly with its plug and play feature.





























