Beam Load Cells
use the deformation of a spring to measure the strain force applied to it. Also known as: Bending Load Cells
See Also: Beam
-
product
8 Way GPS / GNSS Signal Splitter Passive, 1-2 GHz, N Type, DC Block+200Ω Load 8 Ports
GPS802
INSTOCK Wireless Components, Inc
GPS L1 - L5, GLONASS, Galileo splitterLow Insertion Loss (0.6 dB avg)High Port to Port Isolation (30 dB avg)Excellent VSWR (1.15 : 1 avg)15 VDC & 75 mA max on DC block portsTri Alloy N Type Female (Jack) 50 Ohm
-
product
Spring Loaded LVDT Position Sensors
Gage head LVDTs are ideal for industrial environments requiring a reliable and rugged sensor. With near infinite resolution and excellent repeatability, these spring-loaded LVDTs are ideal for quality testing and gaging with several customization options available.
-
product
12V 0-500 Amp Carbon Pile Battery Load Tester and 12/24V Electrical Systems Tester
6042
• Test batteries up to 1000 CCA• Interprets data from the charging/starting system on easy-to-read LCD displays• Shows positive and negative amps for easy diagnosis of current leakage problems• 0-500 Amp variable carbon pile load tester• Unique curved carbon discs ensure maximum contact, fewer hot spots, smoother operation and longer life• Heavy-duty single extruded leads for testing up to 15 feet apart• Test electrical systems on 12/24 Volt systems• Test all battery types• Ideal for testing remotely mounted batteries accurately• INCLUDES: Model 6043 1000 Amp AC/DC Inductive Amp Clamp for checking starter draw or parasitic drain test, also can be used with conventional multi-meters; heavy duty, two wheel tilt-back cart with 8” wheels and 2 trays.• Made in USA of US and Global Components
-
product
3U VPX RL Thermal Load Simulation Module
The 3U power test module is an ideal solution for evaluating heat dissipation in a rugged conduction cooled VPX cage or chassis. This card is a thermal load in the chassis to evaluate the heat dissipation. The chassis can be monitored with temp sensing probes and or FLIR imaging. Different wattages are selected by setting dip switches. The +5 and 3.3V loads are on the top of the module. The +12V and -12V loads are on the bottom side of the module.
-
product
Power Supplies And Loads
Power Supplies and Loads power devices under test (DUTs) such as RF power amplifiers and cellular handsets. The power supply takes in AC power and delivers DC voltage with a fixed polarity, either positive or negative, to its load.
-
product
Rack Mounted Load Banks
Traditional commissioning is a daunting task. Since formal system operation doesn’t begin until the system is commissioned, the commissioning team experiences intense pressure to complete the commissioning process quickly. Commissioning can involve high expense and requires staffs from different departmental disciplines to work together. For these reasons data center commissioning has almost uniquely been associated with large data centers (over 20,000 ft2 or 1,858 m2). In the recent past, many data center managers chose to roll the dice and perform little or no commissioning, relying only on start-up data to press ahead with launching the new data center. Given the reality of 24x7 operations, however, the alternative of exposure to major system failures and accompanying downtime is no longer an economically viable option. Commissioning has now become a business necessity. JUNXY series AC & DC rack mounted load banks can be used to introduce heat loads and to allow for simultaneous testing of both electrical and cooling systems.
-
product
DC Electronic Load
Model - KM-mPD-501
Kusam Electrical Industries Limited
KM-mPD-501 DC electronic load mainly focuses on the testing of power circuit on PCB. KM-mPD-501 offers a solution for function test of Switch step up, Stepdown, Regulators and Driver IC . Engineer puts components, such as CPU, DSP, FPGA; etc on a PCB after the power circuit has been tested. It’s not complete to use a meter to measure the voltage. KM-mPD-501 offers engineer OVP, OCP and OPP functions that help engineer know the value of overload current . On the other hand, engineer can use a programmable DC power supply (mPP series) to offer external power and connect PCB’s output to KM-mPD-501. Then engineer can easily get output watt, figure out the efficiency of power circuit and check if inductances, capacitances and resistances perfectly work with the power circuit. KM-mPD-501 not only offers loading emulation of current but also provides OVP and OPP. User can use these functions to test solar power battery, rechargeable battery and motor driver. In school laboratory, KM-mPD-501 helps students do experiment on power circuit, linear circuit and driver circuit.
-
product
Smart Load Manager
Nippen Electrical Instruments Co.
This is flush mounting micro controller based instrument with multilayer PCB having SMT components offering accuracy and reliability along with reduction in EMI and EMC interference. These are specially designed to simultaneously measure, display and communicate several electrical parameters. This meter is an Ideal data source for effective Energy management, SCADA, PLC, BMS etc to measure as many as 36 parameters on 23 display pages, which are true RMS. The readings are displayed on 3 line bright Red 7 segment LED, each row/ line having 4 14.2mm high LEDS.
-
product
SIM, Module, ITA, 90 Series, Fully Loaded with pairs of VTAC Standard Pass-Thru and Right Angle Inserts (610151106)
510171102
This fully loaded SIM module kit comes with 34 pairs of VTAC Standard Pass-Thru and Right Angle Inserts (610151106). This kit also includes two PCB brackets for securing module to PCB.
-
product
Bidirectional DC Power Supply + Regenerative Load
62000D
Chroma Systems Solutions, Inc.
Chroma 62000D programmable bidirectional DC power supplies have both power source and load characteristics, two quadrant operation, and allows feedback of the power from the DUT. They can be used for testing renewable energy power systems including PV/storage hybrid inverters, power conversion system (PCS) on charging/discharging, and as a battery simulator. The 62000D also is a fit for testing power components used in electric vehicles, such as bidirectional on-board chargers (BOBC), bidirectional DC convertors, and DC-AC motor drivers, and power conversion simulation tests of batteries in both directions.
-
product
Load Testing
OctoPerf
Use auto-correlations rules and frameworks as well as test validation to quickly create virtual users.
-
product
Parallel Plate Dielectric Test Cell
LT-4203A
The LT-4203A Parallel Plate Dielectric Test Cell is designed for measuring the AC loss characteristics and permittivity of solid laminates and panels per ASTM Standard D150‑98, and implements the guarded electrode (three terminal) measurement preferred as the referee method.
-
product
Single Point Aluminium Load Cell
EST-3
Technopark Automation & Control
The EST-3 is a Single Point Aluminium Load Cell suitable for use on platform scales measuring 400x400mm. It is also an ideal load cell to use on filling machines and conveyor belt scale applications. This load cell is available in capacities from 60kg to 1000kg.
-
product
Semi-auto 4 Point Probe System for Solar Cell Substrate
RG-100PV
*Measurement system for thin film on substrate samples for multi-points measurement*Even pitch and random pitch for Max.1,000 points*2-D/3-D square mapping software for even pitch
-
product
Signal, Insert, Receiver, QuadraPaddle, SIM, 1 Slot (not loaded- for discrete wiring only)
510180101
Signal, Insert, Receiver, QuadraPaddle, SIM, 1 Slot (not loaded- for discrete wiring only).
-
product
Transformer Load Box
FY-H / 645
Wuhan Huatian Electric Power Automation Co., Ltd.
When testing current and voltage transformer, it provides various useful loads, which is an ideal matching product for various transformer verification devices.
-
product
FaithTech Ultra Low Voltage And High Current DC Load
NZ/N Series
Shenzhen FaithTech Technology Co., Ltd.
Ultra low voltage and high current DC electronic load is a high reliability and high performance electronic load product derived from FT conventional electronic load for low voltage and high current test scenarios such as fuel cell test and CPU power supply device test. For different current levels, this product includes two series: NZ and N. The voltage is 0-20V or 40V, in which the NZ series can be loaded with 0V full current, and the N series can be loaded with ultra-low voltage and full current. The load capacity is up to 0V@1200A and 0.2V@5000A . This series of products has high precision and high cost performance, which is your good choice for testing.
-
product
Rod End Load Cell
Futek Advanced Sensor Technology, Inc.
FUTEK’s Rod End Load Cells provide an excellent solution for applications involving Inline Actuators or Hydraulic Jacks with Male/Female Threads. You will find a capacity
-
product
Entry Level Beam Profiling
BeamMic®
BeamMic is simplified set of measurement tools for the entry level beam analysis user. The camera-based beam profiling system consists of a camera and analysis software. Often times, this system will need to be used with beam attenuation or beam sizing accessories, depending on your laser application. BeamMic includes a complete set of high-accuracy measurements, and features a rich graphical interface. For the laser technician, this entry-level software will easily help you quickly become familiar with the many benefits of beam profiling.
-
product
Load Banks
EL08 Series
*Rectifier Test 8kW*All of our Load Banks are continuously rated for Power and Current.
-
product
RC-50 Artificial Phantom Load with Power Factor
480
The RC-50 Artificial Phantom Load with Power Factor (Catalog No. 480) has been re-designed to meet the most exacting requirements. It operates from a single phase source and will deliver current at either unity or 50% power factor at all full load ranges.
-
product
ELECTRIC BRAKE FORCE METER WITH DYNAMIC LOAD SIMULATION AND CIRCUIT TESTING
MDTT9107
*Tests truck-side brake controller output and all towing-lighting functions without a trailer*Displays real-time brake controller output gain and timing*Quickly troubleshoots electrical circuits and ground condition*For use with aftermarket and integrated brake controllers*Microprocessor controlled; simulates trailer brake loads*25' cable allows one-man, in-cab testing of brake controller and all truck-side tow circuits*Use to verify that the vehicle’s adaptive (speed/load sensitive) brake-controller output is functioning properly
-
product
Solar Cell Testers
Solar Cell Testers are integrated systems incorporating Solar Simulator and I-V Measurement systems. PET offers Standard and Advance IV Measurement software. PET Cell Testers are capable of measuring a diverse range of solar cell parameters such as Isc,Voc, Imax,Vmax, Pmax, FF, Rsh, Rs and η cell conversion efficiency, complete light and dark I-V curves. All that needs to be done to test a cell is to load the cell, make electrical probes contact and press “Measure” icon on the I-V Measurement System software. The software will automatically open the Solar Simulator shutter, perform the test and close the shutter after the test is complete. The design is modular in nature and can be easily upgraded. Some options can added at a later time.
-
product
ULTRA Test Cells
The ULTRA Series of high performance MEMS handling, stimulus and test cells provides unparalled flexibility and capability for engineering development, characterization or high volume production test of inertial MEMS (accelerometer, gyroscope) semiconductor devices.
-
product
Battery Cell Surge Tester
19311
The Chroma 19311 series battery cell surge tester is designed for testing the insulation quality between the positive and negative plates of the lead-acid battery cell. This is done by applying a high voltage surge/impulse before the electrolyte injection. Its output voltage can reach up to 6kV. It also has four terminal measurement and 200MHz sampling rate. The Chroma 19311 series has single channel (19311) and multi-channel (19311-10) tester.
-
product
Spectroelectrochemical Cell
SEC-C
Spectroelectrochemistry (SEC) is aimed at the investigation of electrochemical reaction mechanism and the interface structure between electrolyte solution and electrode. Remarkable progress in this field and related technology enables SEC to be applied in wide areas.
-
product
Tension Load Cells
These Load monitoring systems are available in telemetry/wireless (RLP), self-indicating (LLP) and cabled non-indicating (WLP) versions. Towcell a 25kN, wireless tension load cell specifically engineered for the emergency services, salvage and 4 x 4 industries. Ruggedly built and highly accurate load link style load cell dynamometers allow for force and load monitoring across a broad range of industries and applications.
-
product
Micro Power or Micro Coax, SIM Insert, ITA, 26 GHz, 2 POS, 6 Slot (not loaded)
510181110
Micro Power or Micro Coax, SIM Insert, ITA, 26 GHz, 2 POS, 6 Slot (not loaded)Micro Power or Micro Coax patchcords need to be purchased separately.