Measure signals that are not ground referenced.
-
Product
Differential Probes < 1.5GHz
-
Differential active probes are like two probes in one. Instead of measuring a test point in relation to a ground point (like single-ended active probes), differential probes measure the difference in voltage of a test point in relation to another test point
-
Product
High Voltage Differential Probes
-
High voltage differential probes provide high CMRR over a broad frequency range (up to 400 MHz) to simplify the measurement challenges found in noisy, high common-mode power electronics environments. The probe’s design is easy-to-use and enables safe, precise high voltage floating measurements.
-
Product
Differential Probes (4-6 GHz)
-
Differential active probes are like two probes in one. Instead of measuring a test point in relation to a ground point (like single-ended active probes), differential probes measure the difference in voltage of a test point in relation to another test point. Dx10/Dx20/Dx00A-AT 4-6 GHz differential probes are a general purpose probing solution with high input dynamic range and offset.
-
Product
Differential Voltage Probes
DP150/DP200pro
-
The DP differential isolation probes are an important accessory for any laboratory involved in power electronics and high voltage systems. These probes allow isolated and floating measurements with any oscilloscope or data recorder, whilst the oscilloscope can remain grounded. Using a DP150 or DP200pro probe, differential and floating measurements can be made on a variety of ac power systems like 230V/110V ac input power supplies, chopped and switching power supplies, thyristor controllers, variable speed motor drives (PWM signals), motor inrush current and measurement across current shunts. The isolated input is made via two 4mm/banana safety sockets. The BNC output allows easy connection to an oscilloscope. The DP probes can be powered from a 9V battery or external power supply.
-
Product
Low & High Voltage Differential Probes
T3
-
Teledyne Test Tools Low & High Voltage Differential Probes offer end user versatility with all models powered by an external universal power supply and work with any Oscilloscope with a high-impedance BNC input. The range consists of one Low Voltage and three High Voltage models with varying bandwidths to satisfy a wide array of customer applications.
-
Product
Y Lead Adapter for ZD Differential Probes Qty 1
PACC-ZD001
Differential Probe
Y lead Adapter for ZD differential probes Qty 1
-
Product
6 GHz ProBus2 Differential Probe with Adjustable Tip
D600A-AT-PB2
Differential Probe
- Choice of 4 GHz or 6 GHz bandwidth models- Up to 5 Vpk-pk dynamic range with low noise- ±3 V offset range- Low loading and high impedance for minimal signal disturbance- Ideal for DDR2, DDR3, LPDDR2- Deluxe soft carrying case- Innovative QuickLink architecture- Wide variety of tips and leads-- Solder-In Lead-- Optional Positioner (Browser) Tip-- Quick Connect Lead-- Square Pin Lead-- HiTemp Solder-In Lead
-
Product
Digital Oscilloscope
DS6000 Series
-
The 6000 Series Digital Oscilloscopes have 1 GHz of Bandwidth. Detecting high speed signals and device characteristics including ESD, digital video, and differential signals (using an differential probe accessory) is now easier than ever with our most advanced digital oscilloscope platform.
-
Product
1kV, 80 MHz High Voltage Differential Probe with 6m Cable and Auto Zero Disconnect
HVD3106A-6M
Differential Probe
The HVD3000A series of high voltage differential probes cover the fullest range of applications, from 120/240 V switch-mode power supplies through 600 V class and 5 kV electrical apparatus. The table below provides a list of recommended probe models based on specific device under test applications.
-
Product
Replacement Long Alligator Clips for High Voltage Differential Probe
PK-HVA-04
Differential Probe
Replacement Long Alligator Clips for High Voltage Differential Probe
-
Product
Differential Probe
DP-25
-
*Econmical High Voltage Model*25MHz/1400Vp-p Max.*3 Range: x20/ x50/ x200*Input Impedance 4MΩ//1.2PF*Separating Design(Standard No.114205) Convenient & Durable.
-
Product
Differential Probe
DP-02VF
-
*150MHz High Frequency*MAX. Input Voltage:*±40V DC or 80V p-p or AC 28V rms*Bandwidth: DC-150MHz*Input Impedance 1MΩ // 7.5PF*X2, X20 Attenuator*To Ground MAX. Voltage: 40V*Output Impedance 50Ω
-
Product
8 GHz Differential Probe with ProLink Interface
DH08-PL
Differential Probe
Teledyne LeCroy’s DH series 8 to 30 GHz differential probes offer the combination of bandwidth, input range and offset capability to address any high-speed probing requirement from debugging serial data interfaces to validating DDR memory systems. DH series probes provide superior loading characteristics and are calibrated with a custom “fine-tuned” frequency response. The ultra-low loading and flat frequency response ensure accurate measurements.
-
Product
Differential Probe
DP-16K Series
-
*High Frequency Performance Model*Bandwidth:(-3 dB)**DC~100 MHz (DP-16K)**DC~70 MHz (DP-16KM)**DC~50 MHz (DP-16KL)*2 Range: x100, x1000*Input Impedance:**10 MΩ // 10 pF each side to ground*Over Range Indicate LED*Rise Time: 4 ns
-
Product
DH Series High-Temperature Solder-In Tip, 16 GHz BW, 3.5 Vpp Range
DH-HITEMP
-
Teledyne LeCroy’s DH series 8 to 30 GHz differential probes offer the combination of bandwidth, input range and offset capability to address any high-speed probing requirement from debugging serial data interfaces to validating DDR memory systems. DH series probes provide superior loading characteristics and are calibrated with a custom “fine-tuned” frequency response. The ultra-low loading and flat frequency response ensure accurate measurements.
-
Product
Terminals
PK-HVA-05
Terminals
Replacement Spade Terminals for High Voltage Differential Probe
-
Product
Current Probe
DCP-BTA
-
Vernier Software & Technology, LLC
The Current Probe measures DC and low-frequency AC currents up to 600 mA. Use Current Probes in combination with Differential Voltage Probes to investigate Ohm's Law and explore series and parallel circuits. The 0.1 shunt resistor minimizes changes to your circuit. If currents will exceed 1 A, use the High Current Sensor.
-
Product
Acute High Voltage Differential Probe, 20x/200x, 100MHz, 1400V
ADP2100
-
*USB Powered (or Power Bank)*Bandwidth up to 100 MHz*Overrange Indicator*Audible Overrange Alarm*Bandwidth Limit : 5 MHz / Full*Can be used by any DSO which has the USB port(s).*EC Declaration: EN 61010-031:2002 +A1:2008*Double-layer wire for power insulation
-
Product
1kV, 120 MHz High Voltage Differential Probe with Auto Zero Disconnect
HVD3106A
Differential Probe
The HVD3000A series of high voltage differential probes cover the fullest range of applications, from 120/240 V switch-mode power supplies through 600 V class and 5 kV electrical apparatus. The table below provides a list of recommended probe models based on specific device under test applications.
-
Product
1 GHz 60 V Common Mode Differential Probe
DL10-HCM
Differential Probe
60 V of common mode and 80 V differential input range with 1 GHz of bandwidth, make these probes ideal for lower voltage GaN power conversion measurements. The 60 V of common mode is well suited for handling any float of the battery and bulk/absorption voltage during charging, while the 80 V differential input range provide margin for any overshoot.
-
Product
Differential Probe
DP-100
-
*This is the first detachable design (patent for 15 years)*High frequency, big power using. Max. Measuring is 7000Vp-p.I*t is capable for any brand of digital and analog oscilloscopes.*Additional AC Adaptor.*16MΩ high input impedance.
-
Product
2.92mm to ProBus Probe Adapter
L2.92A-PBUS
-
The Teledyne LeCroy LabMaster 10 Zi oscilloscope utilizes precision 2.92mm input connectors to achieve up to 36GHz of input bandwidth. But some applications may require the use of lower-bandwidth probes for performance and cost reasons.The L2.92A-PBUS adapter converts the 2.92mm interface to a ProBus interface. This brings the benefits of a wider selection of probes to the LabMaster 10 Zi from high-impedance ZS active probes to the high-bandwidth WaveLink differential probing system. Full probe power and control is provided through a built-in LEMO interface.
-
Product
Tip Saver for ZD Differential Probe Qty 2
PACC-ZD004
Differential Probe
Tip saver for ZD differential probeQty 2
-
Product
200 MHz, 3.5 pF, 1 MOhm Active Differential probe
ZD200
Differential Probe
With the ProBus interface, the ZD200 becomes an integral part of the oscilloscope. The probe sensitivity and offset are automatically optimized based on the oscilloscope gain settings, so control is transparent to the user. When used with a LeCroy digital oscilloscope, no external power supply is required.
-
Product
1 GHz, 1.0 pF Active Differential probe
ZD1000
Differential Probe
With the ProBus interface, the ZD500, 1000, and 1500 becomes an integral part of the oscilloscope. All probe gain and offset controls are transparent to the user, making it easier to probe the circuit without concern for which gain setting to choose. When used with a LeCroy digital oscilloscope, no external power supply is required.
-
Product
DH Series Solder-In Tip, 30 GHz BW, 3.5 Vpp Range
DH-SI
-
Teledyne LeCroy’s DH series 8 to 30 GHz differential probes offer the combination of bandwidth, input range and offset capability to address any high-speed probing requirement from debugging serial data interfaces to validating DDR memory systems. DH series probes provide superior loading characteristics and are calibrated with a custom “fine-tuned” frequency response. The ultra-low loading and flat frequency response ensure accurate measurements.
-
Product
Differential Probe
DP-16VF
-
*MAX. Input Voltage: ±8KV DC or 16KV p-p or AC 5.6KV rms*Bandwidth: DC-150MHz*Input Impedance 20MΩ // 5PF*X400, X4000 Attenuator*To Ground MAX. Voltage: 3.5KV CAT III*Output Impedance 50Ω
-
Product
500 MHz, 1.0 pF Active Differential Probe
ZD500
Differential Probe
With the ProBus interface, the ZD500, 1000, and 1500 becomes an integral part of the oscilloscope. All probe gain and offset controls are transparent to the user, making it easier to probe the circuit without concern for which gain setting to choose. When used with a LeCroy digital oscilloscope, no external power supply is required.
-
Product
InfiniiMode Active Differential Probe, 1.5 GHz
N2750A
Oscilloscope Probe
The N2750A InfiniiMode differential probe is a new generation of low-cost differential active probes compatible with Keysight InfiniiVision and Infiniium oscilloscopes’ AutoProbe interface. It comes with new operation modes and convenient measurements of differential, single-ended, and common mode signals with a single probe tip, without reconnecting the probe to change the connection. The N2750A probe’s InfiniiMode provides the following modes of operation.
-
Product
MPI PCB Probe Systems
-
MPI Advanced Semiconductor Test
Every MPI manual probe systems can be configured with a variety of different holders for printed circuit boards (PCB’s) in order to provide in addition to on-wafer, versatile, convenient, and accurate Signal Integrity (SI) measurements with single-ended or differential RF probes. Measuring signals at the end of the channel for eye-patterns, deterministic jitter, distortion, TDR (Time Domain Reflectometry) impedance, cross-talk, coupling, and losses, or even S-parameters is easily accomplished.