Temperature Recorders
Record the measurement of heat or cold.
See Also: Recorders, XY Recorders, Chart Recorders, Fault Recorders, Disturbance Recorders, High Speed Data Recorders, Event Recorders, Transient Recorders, Data Recorders
-
Product
Temperature Logger for Thermistor Probe
TGP-4020
-
Loggers with probes can be used to record temperature in awkward to reach areas or applications where a fast time response is required. A versatile range of probes are available for this unit and can measure between -40 to +125C. Like the logger, probes are waterproof to IP68.
-
Product
Temperature Recorder
G0841M
-
Complete solution for temperature record during the transport.
-
Product
Temperature Logger-30 to +50C
TV-4050
-
This data logger is a self-contained temperature recorder with a digital display. The TV-4050 is ideal for monitoring the temperature of offices, cold storage rooms, museum exhibits and many other applications where a visual temperature indication is needed.
-
Product
Temperature Recorder
G0221E
-
Complete solution for temperature record during the transport.
-
Product
Temperature/Relative Humidity Logger-25 to +50C/0 to 100% RH
TV-4500
-
This unit records temperature and humidity using self-contained sensors. It can record temperatures between -25 to +50C and relative humidity between 0 to 100%. The unit is waterproof so it can be used outside.
-
Product
Temperature Data Logger
-
The temperature recording in a process is the most common and widely required application in any process. The commonly used temperature sensors are RTD Pt100 / Pt1000/ Cu53 / Thermistors and different kinds of Thermocouple. In order to avoid electromagnetic interference, the temperature signal is converted to 4-20mA and is carried to the logger. Our range of Temperature Data Logger includes Temperature Humidity Logger, RTD Data Logger, Thermocouple Data Logger and Flameproof Data Loggers.
-
Product
Thermal properties sensor
TP01
-
Hukseflux Thermal Sensors B.V.
TP01 is designed for long term (permanent) installation in soils. It covers the thermal conductivity (λ) range of 0.3 to 4 W/m.K, which is sufficient for most inorganic soil types. The core of TP01 is a differential temperature sensor (2 thermopiles) (1) measuring the radial differential temperature with record breaking sensitivity. The sensor performs a temperature measurement around a heating wire (2).
-
Product
Temperature Data Logger
TGU-4017
-
Self-contained temperature recorder Delayed start option 32,000 readings capacity High accuracy and reading resolution Fast data offload Splashproof case Low battery monitor User-replaceable battery USB or serial download cables User-programmable alarms
-
Product
Temperature Logger with Integral sensor and Probe
TV-4510
-
Dual channel temperature recorder LCD display of current readings 30,000 readings capacity High accuracy and reading resolution Fast data offload Splashproof case Low battery monitor and battery low indicator Programmable alarms Optional audible alarm box USB and serial download cables
-
Product
Temperature Logger
TGU-4020
-
This unit uses an external probe (not included) to record temperature in awkward to reach areas or applications where a fast response is required. It can also measure higher temperatures than the self-contained unit. The tip of the probe can be exposed to temperatures up to 125C.
-
Product
Professional Thermal Camera
FLIR T560
-
Troubleshoot hot spots, find hidden faults, and confirm repairs quickly with the ergonomic, high-resolution FLIR T560. This 640 × 480 (307,200 pixel) thermal imaging camera has a bright 4" LCD and a 180° rotating lens platform, so you can easily and comfortably diagnose electrical or mechanical issues, even in hard-to-reach areas. Advanced on-camera measurement tools such as 1-Touch Level/Span, plus laser-assisted autofocus, ensure you’ll record accurate temperature measurements every time. With on-board FLIR Inspection Route mode, you can download and run survey plans to your camera from FLIR Thermal Studio Pro (with FLIR Route Creator plugin). Together these systems will help you record temperature data and imagery in a logical sequence for faster troubleshooting and repair. The T560 also features FLIR Ignite for automatic uploading of images directly from the camera to the cloud for easy, secure storage and sharing. The purchase of a T560 camera includes a 3-month subscription to FLIR Thermal Studio Pro and FLIR Route Creator.
-
Product
Thermitest
THW-L2
-
Designed with speed and operational simplicity in mind, the Transient Hot Wire (THW-L2) Liquid Thermal Conductivity Meter is an advanced measurement system for direct determination of the thermal conductivity of liquids and pastes in accordance with ASTM D7896-19. In less than 2 seconds, a single measurement of small volumes of liquids and pastes can be accurately and precisely measured for thermal conductivity. Using a non-stationary measurement approach, the THW-L2 uses rapid test times to limit convective effects for samples with a wide range of viscosities. The THW sensor consists of a 60 mm heating wire that is fully inserted into an isothermal sample. A constant current source (q) is used to heat the sensor wire and the temperature rise is recorded by monitoring the change in electrical resistance of the wire. The slope (m) is determined from the plot of temperature rise vs. logarithm of time and is used in the calculation of thermal conductivity (λ). Liquid samples of high thermal conductivity will have a lower slope, while liquid samples with low thermal conductivity will have a higher slope.
-
Product
Temperature and Humidity Data Logger
U3121M
-
The Datalogger is designed to record temperature and humidity from expternal probe. In case of exceeded set limits, SMS and JSON messages can be sent via GPRS data connection. It is possible to set the regular sending of JSON messages to Comet Database, the sending interval is adjustable.The recording is performed in a non-volatile electronic memory. The data can be transferred to a PC via USB-C.
-
Product
Double Way Data Logger
VA602-A2-R2
-
Shanghai Yi Hua V&A Instrument Co., Ltd. CO.,LTD
This multimeter with 2 tunnel ,can record temperature or humidty or curruct at same time.
-
Product
Temperature And Humidity Data Loggers
-
These dataloggers are used to monitor and record temperature and/or humidity. Available in either single or multi channel inputs for thermocouple, RTD, thermistor, & infrared temperature sensors.
-
Product
Thermal Data Logger
51101 Series
-
It is a general requirement to record temperatures, voltages, currents, and many physics quantities during research, product development, productions, and quality assurance processes. The number of record channels can be a simple one to several complicated set of hundreds. Thermal/multi-function data loggers are prefect solutions to serve for these measurement and tracking needs.
-
Product
LoRaWAN® Enabled Temperature And Humidity Sensor
EVA-2310
Temperature Sensor
LoRaWAN® wireless connectivity-20 °C to 55 °C temperature detection range0%RH to 90%RH humidity detection rangeBattery life up till 5 years@25 °C, 15 mins interval settingEasy to deploy and maintain
-
Product
T-Type Thermocouple, 32°F to 500°F Temperature Sensor
745685-T02
Temperature Sensor
T-Type Thermocouple, 32°F to 500°F Temperature Sensor - The T-Type Thermocouple works with NI measurement devices and software to help you acquire temperature data within a measurement system. You can use LabVIEW or FlexLogger software and NI-DAQmx driver software to configure … measurements and predefined scaling coefficients for the T-Type Thermocouple and acquire synchronized temperature data in units of degrees. The T-Type Thermocouple is available in various lengths and configurations including field-cuttable, ready-made sensors, and thermocouple wire extensions with a -20°F to 221°F temperature range.
-
Product
Temperature Data Logger
DL001
-
Record temperature in a wide range of applications including HVAC testing and balancing, transportation, and energy management with the Model DL001 Temperature Data Logger. Temperature logger has an on-board thermistor and an external sensor channel for remote temperature measurements
-
Product
sbRIO-9213, Non-Enclosed, 16-Channel, 75 S/s Aggregate, ±78 mV C Series Temperature Input Module
781210-01
Temperature Input Module
Non-Enclosed, 16-Channel, 75 S/s Aggregate, ±78 mV C Series Temperature Input Module - The sbRIO-9213 is a high-density thermocouple input module that is designed for higher-channel-count systems. With this module, you can add thermocouples to mixed-signal test systems without taking up too many slots. The sbRIO-9213 includes anti-aliasing filters, open-thermocouple detection, and cold-junction compensation for high-accuracy thermocouple measurements. The sbRIO-9213 features NIST-traceable calibration and a channel-to-earth ground double isolation barrier for safety, noise immunity, and high common-mode voltage range. Non-enclosed modules are designed for OEM applications.
-
Product
NI-9216, 8-Channel, 400 S/s Aggregate, 0 Ω to 400 Ω, PT100 RTD C Series Temperature Input Module
783863-02
Temperature Input Module
8-Channel, 400 S/s Aggregate, 0 Ω to 400 Ω, PT100 RTD C Series Temperature Input Module - The NI‑9216 is a resistance temperature detector (RTD) input module. You can configure the NI‑9216 for two sample rate modes: high sample rate or high resolution. The NI‑9216 is compatible with 3‑ and 4‑wire RTD measurements, and it automatically detects the type of RTD (3-‑or 4‑wire) connected to the channel and configures each channel for the appropriate mode. The module provides per channel current excitation. The NI‑9216 features calibration and includes a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and a high common-mode voltage range.
-
Product
NI-9216, 8-Channel, 400 S/s Aggregate, 0 Ω to 400 Ω, PT100 RTD C Series Temperature Input Module
785186-01
Temperature Input Module
8-Channel, 400 S/s Aggregate, 0 Ω to 400 Ω, PT100 RTD C Series Temperature Input Module - The NI‑9216 is a resistance temperature detector (RTD) input module. You can configure the NI‑9216 for two sample rate modes: high sample rate or high resolution. The NI‑9216 is compatible with 3‑ and 4‑wire RTD measurements, and it automatically detects the type of RTD (3-‑or 4‑wire) connected to the channel and configures each channel for the appropriate mode. The module provides per channel current excitation. The NI‑9216 features calibration and includes a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and a high common-mode voltage range.
-
Product
Immersion Temperature Probe
U1181A
Temperature Probe
Measure the temperature of food, oil, and other liquids within the range of -50°C to 700°C.
-
Product
NI-9226, 8-Channel, 400 S/s Aggregate, 0 Ω to 4000 Ω, PT1000 RTD C Series Temperature Input Module
783864-02
Temperature Input Module
8-Channel, 400 S/s Aggregate, 0 Ω to 4000 Ω, PT1000 RTD C Series Temperature Input Module - The NI‑9226 is a resistance temperature detector (RTD) input module. You can configure the NI‑9226 for two sample rate modes: high sample rate or high resolution. The NI‑9226 is compatible with 3‑ and 4‑wire RTD measurements, and it automatically detects the type of RTD (3‑ or 4‑wire) connected to the channel and configures each channel for the appropriate mode. The module provides per-channel current excitation. The NI‑9226 features calibration and includes a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and a high common-mode voltage range.
-
Product
FD-11613, 8-Channel Temperature Input Device for FieldDAQ
785640-01
Temperature Input Module
8-Channel Temperature Input Device for FieldDAQ - The FD-11613 measures up to eight thermocouple channels. It features cold-junction compensation and open thermocouple detection with an LED indicator per channel to identify disconnected thermocouples. The FD-11613 has an ingress … protection rating up to IP67 (dust- and water-resistant), can operate in -40 °C to 85 °C environments, and can sustain 100 g shock and 10 g vibration. The FD-11613 incorporates Time Sensitive Networking (TSN) and features an integrated network switch and built-in power circuitry for simple daisy chaining. You program the FD-11613 with NI-DAQmx, which automatically synchronizes multiple FieldDAQ™ devices. This device is ideal for test cell and outdoor environments.
-
Product
LoRaWAN® Enabled Temperature PT1000 Round Head Probe Sensor
EVA-2311
Temperature Sensor
LoRaWAN® wireless connectivity-70°C to 200°C temperature detection rangeIP67 for PT1000 Round Head Probe SensorBattery life up till 5 years@25°C, 15mins interval settingEasy to deploy and maintain
-
Product
NI-9214, 16-Channel, 68 S/s Aggregate, ±78 mV, Isothermal C Series Temperature Input Module
781510-01
Temperature Input Module
16-Channel, 68 S/s Aggregate, ±78 mV, Isothermal C Series Temperature Input Module - The NI‑9214 is a high-density thermocouple input module that is designed for higher channel count systems. The NI‑9214 includes features to increase overall accuracy, such as CJC sensors in the terminal block, component layout to minimize thermal gradients, and an autozero channel for offset error compensation.
-
Product
NI-9212, 8-Channel, 95 S/s/ch Simultaneous, ±78 mV C Series Temperature Input Module
782975-01
Temperature Input Module
8-Channel, 95 S/s/ch Simultaneous, ±78 mV C Series Temperature Input Module - The NI‑9212 offers channel‑to‑channel, isolated thermocouple input channels. The NI‑9212 channel‑to‑channel isolation protects channels from continuous voltages up to 250 Vrms and transient (withstand) voltages up to 1500 Vrms. You can use the NI‑9212 in a variety of applications that are not conducive for bank-isolated channels such as white goods testing, in-vehicle data logging, battery stack testing, as well as in various other noisy industrial environments.
-
Product
NI-9212, 8-Channel, 95 S/s/ch Simultaneous, ±78 mV C Series Temperature Input Module
785259-01
Temperature Input Module
8-Channel, 95 S/s/ch Simultaneous, ±78 mV C Series Temperature Input Module - The NI‑9212 offers channel‑to‑channel, isolated thermocouple input channels. The NI‑9212 channel‑to‑channel isolation protects channels from continuous voltages up to 250 Vrms and transient (withstand) voltages up to 1500 Vrms. You can use the NI‑9212 in a variety of applications that are not conducive for bank-isolated channels such as white goods testing, in-vehicle data logging, battery stack testing, as well as in various other noisy industrial environments.