RF Sources
Produce Radio Frequency (RF) signal.
-
Product
1.85 mm, 1.85 mm (1.85 mm–1.85 mm) RF Cable
138285-1000
RF Cable
RF Cable, 1.85mm (M) to 1.85mm (M), 1.000 Meter Length, 67 GHz
-
Product
50Ω UWave SMA 2.92 Cable Assembly, 40GHz, 0.25m
40-977-544-0.25m
RF Cable Assembly
50 Ohm uWave SMA 2.92 Plug to uWave SMA 2.92 Plug Cable Assy, 0.25m Long.
-
Product
75 Ohm 1.0/2.3 Cable Assembly
40-977-731-0.1m
RF Cable Assembly
Pickering Interfaces offer a range of RF cable assemblies to complement our extensive range of PXI, LXI, PCI, VXI and GPIB switching products. All cable assemblies are made from high quality materials and use best practice assembly methods to ensure the cabling matches the performance of the switching modules they support.
-
Product
4-Quadrant General-Purpose Source/Measure Unit, ±20 V, ±1 A Or ±6 V, ±3 A, 20 W
N6784A
Source Measure Unit
The Keysight N6784A is a source/measure unit (SMU) designed for general-purpose precision sourcing and measurement. General-purpose applications can span many different industries and many different devices under test (DUTs). The N6784A SMU is a versatile tool designed to tackle many of these general-purpose applications. Its glitch-free operation ensures safe usage with the DUT during output and measurement range changes, even with capacitances of up to 150 µF. Its 4-quadrant operation enables it to act as a bipolar power supply or a bipolar electronic load, for added versatility. When using the N6784A SMU, engineers can be confident that they have an all-around general-purpose tool for their test systems or lab bench.
-
Product
75 Ohm F-Type to F-Type Cable Assembly
40-977-781-0.1m
RF Cable Assembly
Pickering Interfaces offer a range of RF cable assemblies to complement our extensive range of PXI, LXI, PCI, VXI and GPIB switching products. All cable assemblies are made from high quality materials and use best practice assembly methods to ensure the cabling matches the performance of the switching modules they support.
-
Product
MS-M Style 26-Pin RF Cable, Female To SMB, 2m, RG178 Cable
40-979-526-2m-SMB
RF Cable Assembly
This 1m long MS-M style RF 26-Pin cable assembly is constructed from RG178 Silver Plated Copper Clad Steel Wire with PVC insulation and an attenuation of 1.08dB/m at 400MHz. Screwlocks are provided to secure the MS-M style connector to the associated product.
-
Product
Basic RF Spectrum Analyzers
RF Spectrum Analyzer
Our low-cost RF spectrum analyzers deliver general-purpose functionality and great value with measurement frequencies from 9 kHz to 7 GHz or 1 MHz to 20 GHz. Get the RF spectrum analyzer accuracy you expect with a variety of options provided to you by Keysight.
-
Product
75 Ohm BNC to MCX Adaptor Assembly
40-978-781-1m
RF Cable Assembly
Pickering Interfaces offer a range of RF cable assemblies to complement our extensive range of PXI, LXI, PCI, VXI and GPIB switching products. All cable assemblies are made from high quality materials and use best practice assembly methods to ensure the cabling matches the performance of the switching modules they support.
-
Product
3.5 Mm-3.5 Mm RF Cable
137445-01
RF Cable
RF Cable, 3.5mm (M) to 3.5mm (M), 1.000 Meter Length, 26.5 GHz, High Performance Phase Stable
-
Product
75 Ohm BNC to BNC Cable Assembly
40-977-701-0.1m
RF Cable Assembly
Pickering Interfaces offer a range of RF cable assemblies to complement our extensive range of PXI, LXI, PCI, VXI and GPIB switching products. All cable assemblies are made from high quality materials and use best practice assembly methods to ensure the cabling matches the performance of the switching modules they support.
-
Product
75 Ohm SMZ/Type 43 Cable Assembly
40-977-711-0.1m
RF Cable Assembly
Pickering Interfaces offer a range of RF cable assemblies to complement our extensive range of PXI, LXI, PCI, VXI and GPIB switching products. All cable assemblies are made from high quality materials and use best practice assembly methods to ensure the cabling matches the performance of the switching modules they support.
-
Product
75 Ohm SMZ/Type 43 Cable Assembly
40-977-711-0.25m
RF Cable Assembly
Pickering Interfaces offer a range of RF cable assemblies to complement our extensive range of PXI, LXI, PCI, VXI and GPIB switching products. All cable assemblies are made from high quality materials and use best practice assembly methods to ensure the cabling matches the performance of the switching modules they support.
-
Product
Tunable Laser Source - PXI
Laser 1000 Series
Laser Source
The Laser 1000 Series PXIe module is a Continuous Wave (CW), tunable laser source offering high-power output, narrow 100kHz linewidth and 0.01pm resolution tunability.With seamless PXI integration, it can be easily integrated into new or existing PXI test setups. Save space, lower your costs and improve testing efficiency while delivering reliable and repeatable results in production or research environments.
-
Product
PXI-4132, 100 V, 2 W Precision PXI Source Measure Unit
780558-01
Source Measure Unit
±100 V, 10 pA Precision PXI Source Measure Unit—The PXI-4132 is a programmable, high-precision source measure unit (SMU). It has a single isolated SMU channel that offers a four-quadrant output that incorporates remote (4-wire) sense as well as external guarding. With its high measurement resolution integrated guarding, the PXI-4132 is ideal for high-accuracy leakage measurements on integrated circuits, discrete components, PCBs, and cables. You can also perform high-speed I-V measurements on a variety of components including diodes and organic LEDs using the onboard hardware sequencing engine. In addition, you can synchronize multiple PXI-4132 modules using the PXI backplane to provide high-speed I-V measurements on transistors and more complex devices.
-
Product
PXIe-4137, ±200 V, ±1 A DC, ±3 A Pulsed, Up to 40 W DC, 100 fA Precision System PXI Source Measure Unit
783761-02
Source Measure Unit
PXIe, ±200 V, ±1 A DC, ±3 A Pulsed, Up to 40 W DC, 100 fA Precision System PXI Source Measure Unit - The PXIe-4137 is a high-precision, system source measure unit (SMU). It features 4-quadrant operation and sources up to 40 W of DC power and can pulse up to 500 W. Analog-to-digital converter technology helps you perform high-precision measurements with a current resolution of 100 fA or high-speed acquisitions up to 1.8 MS/s. The module also can maximize stability and measurement accuracy with SourceAdapt technology, which you can use to tune the transient response to match the characteristics of any load. The PXIe-4137 is ideal for a broad range of applications including manufacturing test, board-level test, and lab characterization with devices such as ICs, power management ICs (PMICs), and RFICs and discrete devices including LEDs and optical transceivers
-
Product
RF Bridge, 50 Ohm, 300 kHz to 3 GHz
86205B
RF Bridge
The Keysight 86205B high directivity 50 ohm RF bridge offers unparalleled performance in a variety of general-purpose applications. It is ideal for accurate reflection measurements and signal leveling applications.
-
Product
75 Ohm Mini SMB to BNC Adaptor Assembly
40-978-701-0.1m
RF Cable Assembly
Pickering Interfaces offer a range of RF cable assemblies to complement our extensive range of PXI, LXI, PCI, VXI and GPIB switching products. All cable assemblies are made from high quality materials and use best practice assembly methods to ensure the cabling matches the performance of the switching modules they support.
-
Product
50 Ohm SMA to SMA Cable Assembly
40-977-521-0.25m
RF Cable Assembly
Pickering Interfaces offer a range of RF cable assemblies to complement our extensive range of PXI, LXI, PCI, VXI and GPIB switching products. All cable assemblies are made from high quality materials and use best practice assembly methods to ensure the cabling matches the performance of the switching modules they support.
-
Product
50 Ohm MCX to MCX Cable Assembly
40-977-561-2m
RF Cable Assembly
Pickering Interfaces offer a range of RF cable assemblies to complement our extensive range of PXI, LXI, PCI, VXI and GPIB switching products. All cable assemblies are made from high quality materials and use best practice assembly methods to ensure the cabling matches the performance of the switching modules they support.
-
Product
Source Measure Units
NGU
Source Measure Unit
Thanks to their extremely high accuracy and fast load recovery time, the R&S®NGU source measure units (SMU) are perfect for challenging applications. A special ammeter design is used to precisely measure current drains from nA to A in one pass – no need to make multiple measurement sweeps. The instruments’ short recovery times enable them to handle fast load changes that occur, for example, when mobile communications devices switch from sleep mode to transmit mode. With high speed data acquisition, every detail is detected down to 2 μs resolution.
-
Product
PXIe Source/Measure Unit, 15 MSa/s, 1 PA, 60 V, 3.5 A DC/10.5 A Pulse
M9602A
Source Measure Unit
The Keysight M9602A is a PXIe SMU featuring best-in-their-class narrow pulse width as narrow as 10 μs. It enables dynamic/pulsed measurements with up to 15 MSa/s for broad emerging applications such as VCSEL optical devices.
-
Product
10-Ch. 0… 5V 400mA Isolated
YAVAP955
Programmable Voltage Source
The YAV board AP955 contents 10 CAN Bus programmable bipolar Isolated precision and low noise 0 to 5VDC voltage sources up to 400mA output, with Tripaddle VPC connector.
-
Product
PXIe-4138, 60 V, 3 A System PXI Source Measure Unit
782856-01
Source Measure Unit
±60 V, 3 A System PXI Source Measure Unit—The PXIe‑4138 system source measure unit (SMU) delivers high power, precision, and speed. It is ideal for a broad range of applications including manufacturing test; board-level test; lab characterization with devices such as integrated circuits (ICs), power management integrated circuits (PMICs), and radio frequency integrated circuits (RFICs); and discrete devices including LEDs and optical transceivers. The PXIe‑4138 features 4-quadrant operation. The PXIe‑4138 is a hardware-timed instrument with a high-speed sequencing engine for synchronizing acquisitions between multiple SMUs. The module supports direct DMA streaming between the host PC and SMU, so you can stream large waveforms and measurement data at the full update rate and sample rate of the instrument.
-
Product
NI-5793, 200 MHz to 4.4 GHz RF Adapter Module For FlexRIO
782512-01
RF Adapter Module
The NI‑5793 provides continuous frequency coverage from 200 MHz to 4.4 GHz. It features a single-stage, direct conversion architecture that provides high bandwidth in the small form factor of a FlexRIO adapter module. The onboard synthesizer, which is the local oscillator (LO), sets the center frequency for acquisition and generation, and you can export it to other modules for multiple input, multiple output (MIMO) synchronization. You can also import the LO from an external connector, enabling synchronization of up to eight NI‑5793 modules.
-
Product
PXIe 5-channel Precision Source/Measure Unit, 500 kSa/s, 10 pA, 30 V, 500 mA
M9615A
Source Measure Unit
The Keysight M9615A is a PXIe five-channel precision source / measure unit (SMU). It supports accurate measurement up to 30 V / 500 mA with resolution down to 6 uV / 10 pA.
-
Product
PXIe-4143, 4-Channel, ±24 V, 150 mA Precision PXI Source Measure Unit
782431-01
Source Measure Unit
PXIe, 4-Channel, ±24 V, 150 mA Precision PXI Source Measure Unit - The PXIe-4143 is a 4-channel source measure unit (SMU) ideal for high-pin-count applications. It features 4-quadrant operation and each channel has integrated remote (4-wire) sensing for accurate measurements. The fast sample rate of the PXIe-4143 can reduce measurement times, capture transient device characteristics, and allow quick I V characterization of devices under test (DUTs). With a high-speed sequencing engine, you can synchronize all these SMUs with each other or with other instruments such as switches or high-speed digital test modules. Additionally, you can tune the PXIe-4143 response to any load to achieve optimum responses with maximum stability and minimum transients using SourceAdapt technology.
-
Product
Source Measure Units (SMUs)
B1511B
Source Measure Unit
The SMUs of B1500A integrate 4-quadrant voltage/current source and measurement capabilities for accurate IV measurement with the range of 0.1 fA - 1 A / 0.5 µV - 200 V. It supports spot, sweep, pulse sampling and QS-CV measurements.
-
Product
50 Ohm MMCX to MMCX Cable Assembly
40-977-571-1m
RF Cable Assembly
This 1m long MMCX cable assembly is part of the range of RF cables. Pickering Interfaces offer a range of RF cable assemblies to complement our extensive range of PXI, LXI, PCI, VXI and GPIB switching products. All cable assemblies are made from high quality materials and use best practice assembly methods to ensure the cabling matches the performance of the switching modules they support.
-
Product
Single-Port Tunable Laser System Source
N7711A
Laser Source
The Keysight N7711A and N7714A tunable lasers are single-port and four-port sources, available with C-band or L-band wavelength coverage. The narrow linewidth and offset grid fine-tuning capability make them ideal sources for realistic loading of the latest transmission systems. All models can reach any wavelength point within their specified wavelength range just like all other Keysight tunable lasers. In this mode, code compatibility with existing test setups based on Keysight's range of full-size and compact tunable lasers is a great asset. In system loading applications, it may be preferable to grid-tune the lasers like system transmitters, simply by changing the channel index. The channel grid is adjustable to standard ITU-T grid spacing like 50 GHz, and to arbitrary grids. Likewise, the zero frequency (base channel) of the chosen grid is adjustable. A 12 GHz fine-tuning range allows de-tuning the frequency.
-
Product
PXI-2596, 26.5 GHz, 50 Ω, Dual 6x1 (SP6T) PXI RF Multiplexer Switch Module
778572-96
RF Multiplexer
26.5 GHz, 50 Ω, Dual 6x1 (SP6T) PXI RF Multiplexer Switch Module—The PXI‑2596 is an RF signal multiplexer switch with dual 6x1 multiplexer banks in the same module. It is ideal for passing high-order harmonics from PXI RF Signal Upconverter modules or routing multiple sources to PXI RF Signal Downconverter modules. You can use the PXI‑2596 onboard relay count tracking feature to predict relay lifetime and reduce unexpected system downtime.





























