MP4
group of audio video digital data compression standard formats.
-
product
Tilt Switch and Control Unit
MTS / SCU-200
Features • Detects the presence or absence of bulk material • Standard enclosure is NEMA 12 with indicator lights • NEMA 4 and Intrinsically Safe enclosures available • Rugged heliarc-welded steel probes • Use with SCU-200 for complete monitoring system
-
product
Chilled Mirror Transmitter
DewTrak II
The DewTrak II uses the chilled mirror dew point temperature condensation principle to determine the water vapor concentration in gas mixtures, and a platinum resistance thermometer to accurately measure that temperature. Outputs include 4 to 20mA, 0 to 5 Vdc, or 0-10Vdc and an RS232 serial port as well as electrically isolated relay contacts.
-
product
PXI 8 Slot BRIC Module, 2 Resource Distributor, 6 Bus Matrix Inputs
40-569B-126
The 40-569B is a range of high-density BRIC matrices capable of switching up to 2A and up to 200VDC/180VAC. These large PXI matrix modules are available with multiple configurations in 4 or 8 slot sizes and are constructed using high-quality electromechanical relays. The 40-569-126 is a 8 slot module fitted with 6 Bus Matrix Inputs cards and 2 Resource Distributor cards.
-
product
Day/Night IP Surveillance Camera
ENVIROMUX-IPCAM-N
View and control the camera from the ENVIROMUX web interface, the camera web interface, included software, or with a compatible cell phone. With the ENVIROMUX-2D/5D/16D, a triggered snapshot can be forwarded in alert e-mails. A snapshot can be triggered by any programmed event (motion detection, door open/close, glass break, smoke, liquid detection, etc.). Image sensor: 1/4" progressive scan CMOS sensor. Video Streaming: simultaneous Motion JPEG and MPEG-4. Frame rate: 30fps at 640x480 (VGA) resolution. Lens: F2.0, 4.3 mm (0.17 in), 12 infrared LEDs for night vision. RJ45 connector. Wireless models: wireless IEEE 802.11 b/g up to 54 Mbps. Regulatory approvals: CE, FCC, RoHS.
-
product
PXI BRIC8 1Resource Distributor, 2Bus Matrix
40-569-112
The 40-569 PXI Matrix BRIC provides a range of high-density bus matrix inputs and resource distributor bussed configurations capable of switching up to 2A and up to 100VDC/70VAC. These large PXI matrix modules are available in 4 or 8 slot sizes and are constructed using high-quality electromechanical relays.
-
product
JadeFX FlexorSet 8-Channel 250 MHz A/D with DDCs - 3U VPX
Model 5983-317
- Jade Xilinx Kintex UltraScale FPGA Products and Navigator Design Suite Software Video- Jade Xilinx Kintex UltraScale FPGA Family Brochure- VITA-57.4 HSFC FMC+ site offers access to a wide range of possible I/O- Supports Xilinx Kintex UltraScale FPGAs- Eight 250 MHz 16-bit A/Ds- Eight multiband DDCs- 4 GB and 5 GB of DDR3 SDRAM- Sample clock synchronization to an external system reference- PCI Express (Gen. 1, 2 and 3) interface up to x8- User-configurable gigabit serial interface- Optional optical interface for backplane gigabit serial interboard communication- LVDS connections to the Kintex UltraScale FPGA for custom I/O and synchronization- Compatible with several VITA standards including: VITA-46, VITA-48 AND VITA-66.4 and VITA-65 (OpenVPX™ System Specification)- Ruggedized and conduction-cooled versions available- Please refer to the product datasheet for Installed FPGA IP Module details
-
product
IEC60335-2-9 Clause 3 Figure 104 Vessel For Testing Induction Hotplates
CX-104
Shenzhen Chuangxin Instruments Co., Ltd.
IEC60335-2-9 clause 3 figure 104 Vessel for testing induction hotplates Parameter : Pot and lid material is mainly Q235, carbon mass fraction <0.08%; 2. The thickness of the wall material is 2 mm;3. The bottom of the pot body can not be outward convex, can not exceed 0.05mm; 4. Pot body and lid surface to be clean 5, size: 110, 145, 180, 220, 300mm each one
-
product
Low-Profile Modular Power System Mainframe, 400W, 4 Slots
N6700C
The Keysight N6700C is a 400 W 1U high, 4-slot modular power system mainframe that accepts from 1 to 4 N6700 series DC power modules in any combination. Modules are ordered separately. The N6700C offers GPIB, LAN, and USB, interfaces standard, and LXI compliance. Select from more than 20 different DC power modules, ranging in capability from basic to high precision, and in power from 20 - 300 W.
-
product
Three-axis Fluxgate Magnetometer
TFM1186
The Three-axis Fluxgate Magnetometer TFM1186 is a member of Metrolab's THM1176 family of 3-axis handheld magnetometers. It is a lightweight, low-power, go-anywhere fluxgate magnetometer. Outstanding noise characteristics make fluxgate magnetometers the instrument of choice for measuring minute disturbances in the local magnetic field, for example due to an iron mass or AC power-line noise. The TFM1186 has a range of ±100 µT and a resolution of 4 nT. The TFM1186 simultaneously measures all three axes of the magnetic field, so you get a true field strength reading no matter how you hold the probe. The entire instrument has been reduced to a cable with a few fat spots, which can plug directly into your PC or into a battery-powered handheld computer. 3-axis Teslameter Gaussmeter
-
product
19" Rackmount Drawer, Unshielded, 8.75"H x 24"D
DR-081924
Unshielded drawers are constructed of 20 ga. CRS and are furnished with ball bearing chassis slides to provide smooth operation. Available for 19" and 24" rackmount in 20", 24" and 30" depths, with or without a keylock
-
product
Multilogger
M1320
Universal datalogger with 4 hardware inputs. Multilogger can be installed permanently to Ethernet network or work as portable device. Included is traceable calibration certificate in accordance with EN ISO/IEC17025.s portable device.
-
product
PXI 4 Slot BRIC 220x4 2-pole (5 sub-cards)
40-562A-022-220X4
This version of our BRIC is part of a range of high-density PXI matrix modules. These modules are available in 2, 4 or 8-slot PXI sizes to suit all high performance matrix requirements and are constructed using instrumentation quality reed relays. With this high level of switching density, these PXI matrix modules allow a complete Functional ATE system to be housed in a single 3U PXI chassis. These BRIC matrix modules allow the use of lower cost 8 or 14-slot PXI chassis.
-
product
MICRO OHM-METER
UONT100A
International Biological Laboratories
This Test Set is capable to measure low resistance like switch contacts, breaker contacts, busbar splices, joints, fuses, low inductive windings etc. by circulating high value of D.C. through the contact/junction and measuring D.C voltage drop (4 terminal method) which, sent to instrument amplifiers , thereby being displayed on resistance meter.
-
product
Mixed Signal Oscilloscope: 350 MHz, 4 Analog Plus 16 Digital Channels
MSOX3034A
InfiniiVision 3000 X-Series 350 MHz oscilloscope provides 4 analog plus 16 digital channels, up to 4 Mpts memory, and 1,000,000 waveforms/sec update rate
-
product
Improved Data Modem
IDM-401
The IDM-401 configured with the new CCA’s consumes 75 W of total power and results in a 1.5 lb. weight reduction. Total 3U slots required is reduced from 7 to 4. The overall IDM-401 chassis outline design and dimensions are maintained. Three (3) Spare 3U OpenVPX slots offer expansion capability for additional IO, communications or video input/output!
-
product
Qty. 3 MCX 4 GHz Solder-In Lead Accessories
RP4000-MCX-LEAD-SI
Qty. 3 MCX 4 GHz solder-in lead accessories (additional to those supplied with RP4030), 18cm long
-
product
LXI Microwave Multiplexer, 50Ω 4-Channel 6-Bank 26.5GHz SMA
60-802-306
The 60-802-306 is a 4-channel, 6-bank RF multiplexer suitable for switching 50Ω signals up to 26.5GHz. It is part of Pickering Interfaces’ range of LXI Microwave Multiplexers which are available with bandwidths between 6GHz and 40GHz and support for 4, 8 12 or 16 banks of 4 or 6-channel multiplexers. It is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA or SMA-2.9 connectors.
-
product
Thermometer Hygrometer
Model 302
1. Time,date display.2. Time alarm clock every day.3. 12/24 hours system clock.4. ℃/℉ temperature display.5. Relative humidity and comfort display.6. Temperature and relative humidity trend display.7. Max/Min Temperature and relative humidity display.8. Temperature measure range: -20℃~50℃9. Temperature resolution: 0.1℃10. Temperature accuracy: ±1℃11. Humidity measure range: 10%~95%RH12. Humidity resolution: 1%13. Humidity accuracy: ±5%RH14. Measuring period: 20 sec15. Power: 1.5V (AAA or 7# battery)
-
product
LAN Cable Tester PRO
PK-168 NextPRO S2
PK-168 is capable of wire mapping by pin & pair up to 600 meters,PK-168P: Remote unit come with PoE detector. It detects presence of PoE and displays type of PoE either end-span A or mid-span B or ultra power over 4 pairs and either 802.3af (PoE) or 802.3at (PoE+) is present.
-
product
PXI 4 Slot BRIC 44x16 2-pole (4 sub-cards)
40-562A-022-44X16
This version of our BRIC is part of a range of high-density PXI matrix modules. These modules are available in 2, 4 or 8-slot PXI sizes to suit all high performance matrix requirements and are constructed using instrumentation quality reed relays. With this high level of switching density, these PXI matrix modules allow a complete Functional ATE system to be housed in a single 3U PXI chassis. These BRIC matrix modules allow the use of lower cost 8 or 14-slot PXI chassis.
-
product
Single-ended, Direct Connect Probe, 34-Channel, 4 X 160-pin
U4206A
The U4206A is a direct-connect probe/cable with a standard soft touch pro connector at one end that routes to four 160-pin connectors that plug into the front panel connectors of a U4164A logic analyzer module. The U4206A is designed to be used with either the quad state mode or ¼ channel 10 GHz timing mode of the U4164A logic analyzer module. For use in quad state mode only, the U4206A includes two flying leads to connect additional clock qualifier signals into the clock inputs on Pods 3 and 7. Please refer to the U4164A installation guide for specific details on the operation of the U4164A quad sample state or ¼ channel 10 GHz timing modes of operation.
-
product
ARINC825 (CAN Bus) Test & Simulation Module for PCI With 2 Or 4 CAN Bus Nodes
ACP825-x
ARINC825 (CAN bus) Test & Simulation module for PCI with 2 or 4 electrically isolated CAN bus nodes operating concurrently at CAN bus high speed bit rate of up to 1Mbit/s. The ACP825-x PCI card can work either with full functionality as an active CAN node for testing and simulating or in Listening Only mode for monitoring and recording purposes.
-
product
Surface & Volume Low Resistivity Meter for Conductive Materials
Loresta GP
The Loresta GX Meter is an intelligent, multi purpose low resistivity meter equipped with software that calculates resistivity correction factors. A variety of 4 pin probes are available for use with the Loresta GX. The instrument is typically used in Product Engineering, R&D, and Quality Control. Applications include measurement of conductive paint, conductive plastics, conductive rubber, conductive film, silicon wafers, antistatic materials, EMI shield materials, conductive fiber, conductive ceramics, etc.
-
product
Accessory EFT/Burst generators IEC 61000-4-4
The field sources and the burst transformer are used to harden the device under test. They are powered by an EFT/burst generator.
-
product
7-WAY Blade & 4 Flat Connector Tester
3536B
Peaceful Thriving Enterprise Co Ltd
This is a tester to test the function of the 7 way connector of the vehicle. User simply plug the tester with the 7 way or 4 way connector, and switch on the corresponding function of the vehicle to check if the LED indication has lighted up correctly. Use in the garages, workshops where there is a need to check the configuration of circuit. Widely used to test trailer light circuits on most trucks, boats, trailer campers, caravans, food trucks and other trailers.
-
product
NEXTest 7
PK-2030/2032/2033/2036/2037/2038
NEXTest 7 is an advanced and unique tester in the market. It's designed to check and troubleshoot the pin connections of Display port & HDMI prior to installation on equipment. By using advanced technology to verify the integrity (20 pins + shield) of both display port and HDMI cables, especially for HDTV installation and DIY termination in the field, solving your cable testing need, unlink all of the other testers verify 9 circuits only. It checks for opens, shorts, miswires and intermittent faults in all conductors plus shield continuity, most tester only test for opens. It displays cable map results of both TX (near end) and RX (far end) on the main unit, either on testing before or after installation cables. User can easily read and determine the actual 21 pins configuration on main unit. It employs both auto and manual scanning of 21 wires. Tone Generator mode transmits two selectable tones on each pin for use with Net Probe (PR-06P) optional, enables one to quickly locate a cable. It's capable of testing up to 8 cables and locations at one time. NEXTest 7 especially features a self-learning mode to memorize cable pin out for testing large quantity standard or custom cables for PASS/FAIL a snap, makes testing quick and more efficient.
-
product
8-Slot BRIC, 420x6, 1 Pole, PXI Matrix (5 Sub-cards)
40-559-801-420x6
This range of BRIC ultra-high-density large PXI matrices are available in 2, 4 or 8-slot PXI sizes to suit all high-performance matrix requirements and are constructed using Pickering Electronics' 4mm x 4mm instrumentation quality reed relays.
-
product
LXI Microwave Multiplexer, SP4T, 12-Bank, 67GHz, 50Ω, SMA-1.85
60-803-812
Our 60-803-812 is a 12 bank SP4T multiplexer and is part of a range of LXI based microwave multiplexers suitable for switching 50 ohm signals up to 67GHz. The 60-803 range is capable of supporting up to 16 banks of 4 channel multiplexers it is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA, SMA-2.9, SMA-2.4 or SMA-1.85 connectors.
-
product
Energy Dispersive X-ray Fluorescence Spectrometer
Pharmaceutical Elemental Impurities Analysis System
Control of Elemental Impurities in Pharmaceuticals In the pharmaceutical industry, the analysis of elemental impurities is necessary to ensure the safety of pharmaceuticals. In December 2014, the "Guideline for Elemental Impurities" (Q3D) was issued by the International Council for Harmonisation of Technical Requirements for Pharmaceuticals for Human Use (ICH), consisting of representatives from Europe, the U.S. and Japan. In Japan, the "Guideline for Elemental Impurities in Drug Products" (PFSB/ELD Notification 0930 #4 from the Ministry of Health, Labour and Welfare) was issued, and will be applied to new drug products submitted for approval after April 1 2017. For 24 elements categorized in Class 1 to Class 3, residual quantities in pharmaceutical drug products must be controlled within permissible limits. Although ICP-AES and ICP-MS are used for precise analysis of elemental impurities, X-ray fluorescence spectrometers can be used as an alternative analysis method. This is because they can quantitatively and qualitatively analyze a variety of elements nondestructively, and without chemical pretreatment, unlike ICP-AES and ICP-MS systems. The X-ray fluorescence spectrometry has been adopted as a general method of analysis in the U.S Pharmacopeia and the European Pharmacopoeia. (USP<735>, Ph.Eur.2.2.37)