The Laplace products are designed and manufactured in he UK, we enable manufacturers to reduce the cost of EMC Testing, increase productivity and reduce the product time to market.
- +44 (0) 16 92 40 20 70
- tech@laplace.co.uk
- Tudor House
Grammar School Road
North Walsham, Norfolk NR28 9JH
United Kingdom of Great Britain and Northern Ireland
-
product
Power Amplifiers
RF Range
The RF power amplifier range from Laplace is specifically designed for EMC Immunity testing. These are compact units with characteristics matched to the requirements of IEC standards.
-
product
Antennas for EMC testing
The Laplace antennas cover 3 main groups...*Conventional log periodic types for OATS applications.*Miniature antennas for chamber and small enclosure applications.*Large loop antenna for EN55015 compliance testing.
-
product
RF Synthesiser
The Laplace Synthesisers cover both conducted and radiated RF immunity test requirements. The frequency coverage extends from 100KHz to 230MHz for conducted tests and 30MHz - 6GHz for radiated tests. They are all controlled from the users PC via a USB link, and powerful Windows software is included to enable the user to control all the parameters of the test, to monitor the test in progress, and to view the results.
-
product
Near Field Probe Set
RF100
The RF100 probe set consists of a passive E field probe and H field probe, BNC adaptor and carry case. The output is via a BNC socket. These are general purpose probes which are ideal for use in conjunction with an EMC measuring system. They are sensitive to sources in close proximity, but are insensitive to background signals. This makes them ideal for the identification of emission frequencies in noisy environments... thus making measurements easier and quicker. The proximity requirement also enables sources to be located and the exit route identified.
-
product
Ultra-Compact Immunity Tester
AXOS5
The AXOS5 is an ultra-compact immunity tester that performs all the most commonly used transient immunity tests, including Surge, EFT, Dips/Interrupts and AC/Surge Magnetic Field. The simplified user interface provides quick selection of tests and test levels, and even lets you change test parameters “on the fly” while running a test.The actual EUT power mains voltage and current are indicated in the display. Using the Electronic-Fuse function, the user can set an upper limit for EUT power mains current. This feature is useful to protect the EUT from unnecessary damage.Whether you test to the IEC 61000 series “CE Mark” standards, the IEC 60601 Medical Device standards, or any number of telecom and product specific standards, the AXOS5 tester is your one stop test station for everything from precompliance to full compliance to product development testing.A wide range of cost-efficient Coupling / Decoupling Networks for symmetrical and asymmetrical data- and signal-lines is available as an option.
-
product
LETIS
Power amplifiers that are universally used for radiated immunity testing either cover the range below 1GHz or the range above 1GHz. This means that if the test requirement extends both sides of this 1GHz point, the power amplifier needs to be changed over. Genrally, this involves three connections... The LETIS handles all these connections automatically. Each is switched via a high performance RF relay under the control of a USB interface. Software issued with the Laplace Synthesisers automatically detects the presence of a LETIS and handles the switching automatically.
-
product
Pre-Selectors for EMC test
These Pre-Selectors are high specification, switched band filters which track the scanning of the EMC Analyser. Control is via USB link from the Laplace EMCEngineer software supplied with SA1002 and SA3000 analysers. Installation and operation is completely automatic, and the filters will synchronise with the analyser scan without any operator intervention. A front panel switch allows manual operation if required.
-
product
Filter Design System - Mode Analyser
EA-300
The EA-300 is a stand alone unit with internal firmware and a large colour display. It connects to the outputs from a standard LISN and feeds the results to any standard EMC analyser or receiver. The EA-300 prompts the user through the steps necessary to fully characterise the emissions from the EUT, then will output via the screen the recommended filter component values that would reduce these emissions to acceptable levels.
-
product
Ultra-Compact Immunity Tester
AXOS8
The AXOS8 is an ultra-compact immunity tester that performs all the most commonly used transient immunity tests, including Surge, EFT, Dips/Interrupts and AC/Surge Magnetic Field. The simplified user interface provides quick selection of tests and test levels, and even lets you change test parameters “on the fly” while running a test.The actual EUT power mains voltage and current are indicated in the display. Using the Electronic-Fuse function, the user can set an upper limit for EUT power mains current. This feature is useful to protect the EUT from unnecessary damage.Whether you test to the IEC 61000 series “CE Mark” standards, the IEC 60601 Medical Device standards, or any number of telecom and product specific standards, the AXOS8 tester is your one stop test station for everything from precompliance to full compliance to product development testing.A wide range of cost-efficient Coupling / Decoupling Networks for symmetrical and asymmetrical data- and signal-lines is available as an option.
-
product
Ancillaries.. Conducted
The ease and effectiveness of conducted emission measurements can be enhanced by the use of appropriate filters. In particular, broadband noise below the frequencies of interest can cause limiting (compression) in spectrum analysers, distorting the measurements.
-
product
Source of Signals
CRS+
The CRS+ is a stable and calibrated source of signals which cover the 9KHz - 30MHz frequency range. The fundamental signal is a 15KHz comb and each harmonic is output as a narrowband peak of known amplitude. This signal is output on either the L and N lines, referenced to ground. A switch provides on/off and line selection.
-
product
Ophir Power Amplifiers
Ophir RF power amplifiers are rugged and reliable. They are available as complete rack mounted units incorporating power supply, fans and heatsinks, or as compact modules requiring a DC supply. Fans and/or heatsinks can be included if required.
-
product
Microrad RF Fieldmeter
Users can measure from static/almost static magnetic fields up to 6GHz utilising only two probes while remaining compliant with Directive 2013/35/EU. This solution is the NHT-3D meter plus 33P and 01E probes
-
product
Clean Power Source
AC1000A
The AC1000 achieves its unique price/performance ratio by actively adjusting the incoming mains waveform to produce a clean output. Other suppliers use convertor techniques to completely recreate the output from scratch. Our solution delivers an output which achieves the required THD with the minimum of hardware and expense. It includes the ability to switch the correction in or out so that the original waveform can be observed and measured if required. Overload and thermal protection systems are built-in and produce an audible warning if activated.
-
product
Harmonics & Flicker Analyser
AC2000A
The Laplace Harmonics and Flicker analyser provides the user with a complete system for testing product compliance with IEC61000-3-2 and IEC61000-3-3. Quick and easy to use, the built-in screen provides a clear pass/fail indication of compliance status, plus a full listing of results for each harmonic, in either tabular of bargraph format. The instrument is properly configured to cope with fluctuating harmonics. The Flicker mode provides proper measurement of short term and long term parameters, using algorithms specified in IEC61000-4-15. In addition, inrush current measurements can be automated such that the product under test can be automatically cycled on/off with user entered time profiles.