product
High Accuracy Decade Capacitance Box
HACS-Z Series
The HACS-Z Series high accuracy capacitance box is capable of meeting exacting requirements for fixed or adjustable calibration capacitance, or any applications requiring precise and stable capacitance values. You can pick the best unit for your application, without overpaying for ranges that you do not require. Models are available with a range of 1 pF - 11,111 F in as few as 3 or as many as 11 decades.
-
product
Cost Effective Capacitance Decade Box
CS Series
The CS Series Capacitance Decade Box is a cost effective and commonly used capacitance decade box for production and educational applications
-
product
Precision Impedance Meter
1689
The GenRad 1689 Precision Impedance Meter gives you the best performance for your most demanding applications whether they be production test, incoming inspection, component design and evaluation, process monitoring or dielectric measurement. It is a versatile, full function microprocessor-based passive component tester that's available in a rack mountable, (1689M) model.
-
product
Resistance Decade Box
HARS Series
The HARS Series is the best choice when you need a laboratory grade, tight tolerance, high performance resistance decade box that is also cost effective.
-
product
Primary Standard Capacitors
GenRad 1404 Series
The GenRad 1404 Series standard capacitors are the standard of choice in metrology labs, and still used today by standards bodies around the world. These capacitors have been designed as primary reference standards of capacitance with which working standards can be compared.
-
product
Programmable Capacitance Decade Box
PCS Series
A broad range of laboratory grade programmable capacitance decade boxes for applications requiring a programmable impedance unit controlled manually and by a computer via an IEEE-488, RS-232 interface.
-
product
Decade Capacitor
GenRad 1423-A
The GenRad 1423 decade capacitor is a versatile tool for calibration laboratories and production-line testing. With it a bridge can be standardized to an accuracy exceeded only by that of the highest quality, individually certified laboratory standards such as the GR 1404 Reference Standard Capacitors.Used with a limit bridge, such as the GR 1689 Digibridge, the 1423 facilities fast and accurate production-line measurements of arbitrary capacitancevalues with minimum setup time.
-
product
Precision Voltage and Current Sources
VI-700
The VI-700 Voltage and Current Source is a versatile precision dialable or remotely programmable voltage and current source. Its three ranges provide up to 20 V full scale (200 V with the HV option), and down to 100 mV resolution; and 20 mA full scale down to 0.1mA resolution. Both voltage and current outputs are available simultaneously. The output is set by a range selector and thumbwheel switches in the LOCAL mode, or by a digital input at the rear panel. The REMOTE mode control can be a RS232 or IEEE-488 interface.
-
product
Decade Resistor
1433 Series
The 1433 Decade Resistors are primarily intended for precision measurement applications where their excellent accuracy, stability, and low zero resistance are important. They are convenient resistance standards for checking the accuracy of resistance-measuring devices and are used as components in dc and audio-frequency applications.
-
product
Capacitance Standard
GenRad 1417
The GenRad 1417 Four-Terminal Capacitance Standard consists of a 1 F standard capacitor and two precise inductive voltage dividers used to scale the value of the 1 F capacitor up to 1 F in decade steps. This arrangement provides accuracy and stability unattainable with very high-value true capacitors.
-
product
Capacitance Bridge
1620
The GenRad 1620-A Capacitance Measuring System is a self-contained assembly of the GR 1615-A Capacitance Bridge with appropriate oscillator and null detector for measurements at 11 frequencies between 20 Hz and 20 kHz. For applications requiring other or higher frequencies, to 100 kHz, the 1615-A bridge can be supplied separately and the oscillator and detector selected to meet your needs.
-
product
Megohmmeter
1863
The GenRad 1863 Megohmmeter is the choice for production and inspection tests on devices with resistances up to 20 Tohms. The GenRad 1863 will measure resistance at any of five test voltages of: 50V, 100V, 200V, 250V, and 500 VDC. Compared to the GenRad 1864, which has adjustable test voltages from 10V to 1090V, this unit has fewer controls, and is the more economical of the two models.
-
product
Capacitance Bridge
1621
The GenRad1621 Capacitance Measurement system is a completely self-contained system capable of capacitance measurements in increments as small as 0.1 aF (10-4 pF) and conductance measurements in increments as small as 100 aU (10-7 U; equivalent to a shunt resistance of 1010 M). Measurements are three terminal, with 2- or 3-terminal connection, and provision is also made for the connection of an external standard for comparison measurements.
-
product
Benchtop LCR Meter
1692
The GenRad 1692 LCR Meter is a sophisticated, microprocessor-controlled tester that brings new levels of flexibility, simplicity and accuracy to RLC measurement. It's testing automation at its best with a range of programmable test frequencies and test voltages, as well as automatic limit comparison, automatic parameter selection, remote programmability, automatic binning and automatic zeroing. The display facilitates visual acquisition of test data and eliminates costly guesswork and errors. The 1692 LCR Meter provides a powerful combination of features designed to maximize productivity in production testing applications.
-
product
Megohmmeter
1864-9700
The GenRad 1864 Megohmmeter is the choice for more demanding applications. The test voltage can be set to any value from 10VDC to 109VDC in 1-volt steps and to 1090VDC in 10 volt steps. Thus the GenRad 1864 can be set to any common, or uncommon test voltage for ceramic, mica or paper capacitors, or other devices. The reverse resistance of rectifiers can be readily measured; the low test voltages are especially useful in measuring solid state diodes. An additional range on the 1864 Megohmmeter permits measurements up to 200 T (2 x 1014)