mks Ophir
Ophir is a brand within the MKS Instruments Photonics Solutions Division. The Ophir product portfolio consists of laser and LED measurement products, including laser power and energy meters, laser beam profilers measuring femto-watt to hundred-kilowatt lasers, high-performance IR and visible optical elements, IR thermal imaging lenses and zoom lenses for defense and commercial applications, OEM and replacement high-quality optics and sub-assemblies for CO2 and high-power fiber laser material processing applications. Ophir products enhance our customers’ capabilities and productivity in the semiconductor, advanced electronics and specialty industrial markets. For more information, visit www.ophiropt.com.
- 1-800-383-0814
435-753 3729 - 435-753 5231
- sales.ophir.usa@mksinst.com
- 3050 North 300 West
North Logan,, UT 84341
United States of America
-
product
NanoModeScan M² Measuring System
This scanning slit M² measurement system accurately analyzes lasers with wavelengths from UV to Far Infrared with its silicon, germanium, or pyroelectric head. It features a compact portable design, immediate results, ISO compliant measurements, and operates in CW or kHz Pulsed modes which makes it ideal for comprehensive analysis of lasers of most wavelengths.
-
product
High Power Thermal Sensors & Power Pucks – 1W to 120kW
15K-W-BB-45
The 15K-W-BB-45 is a water cooled thermal power/energy laser measurement sensor for very high powers with a 45mm aperture. It can measure power from 100W to 15,000W. It has a deflecting cone and annular absorber that withstands high power densities to 10kW/cm². It covers the spectral range from 0.8 - 2 and 10.6µm. The sensor comes with a standard 5 meter cable for connecting to a meter or PC interface.
-
product
*Energy Sensors For IPL Sources
Ophir has several ways to measure intense pulsed light IPL radiation used in cosmetic treatments. The light from these sources is broadband and usually has a high divergence. Furthermore, the light source is often coupled to the skin via an index matching gel. For these reasons, we need special solutions to accurately measure the energy of the IPL pulses.
-
product
*OEM Energy Sensors
The OEM “standard” sensors are actually families of existing OEM sensors with typical specifications shown. They can be tailored as needed to fit your specific requirements. In addition to the products described, Ophir has developed hundreds of other OEM solutions. Simply fill out the Sensor Customization form so we can provide just the right solution for your needs.
-
product
*Beam Profiling For 266nm To 3000µm
Unlike a power meter that measures average or instantaneous Watts or Joules of the overall laser beam, knowing how the power is distributed within the beam is equally as important. As an example, if you want to cut something the power should generally be focused in the center of the beam to concentrate the power density in a very small area but if you were trying to weld something with all the power in the center you would poke a hole in the weld; requiring the power to be equally distributed as in a top hat profile.
-
product
*LED Measurement – UV, VIS, NIR
UV, VIS, and IR LEDs are replacing traditional light sources and are enabling new applications. Ophir offers a number of choices in LED power measurement - use the LED sensor finder to find the right sensor. For cases where a complete image of the beam distribution is necessary, use a beam profiling camera.
-
product
Camera Based Beam Profiling
BeamGage
See your beam as never before with BeamGage®. The camera-based beam profiling system consists of a camera and analysis software. Often times, this system will need to be used with beam attenuation or beam sizing accessories, depending on your laser application. The advantage to camera-based beam profiling is the real-time viewing and measuring of a laser’s structure. BeamGage software includes an extensive set of ISO quantitative measurements, features a rich graphical interface, and features its patented UltraCal™ algorithm, providing the industry’s highest accuracy measurements.
-
product
*High-Power Beam Profiling
Beam analysis of high-powered industrial lasers have always proved to be difficult because of the power levels (affecting the power densities) that these lasers operate at. Yet, the measurement of these lasers are critical for their success because of thermal effects which are more of a factor at these higher powers. These high-power performance measurement products have proven to be solutions for laser users who operate and maintain these high-powered lasers
-
product
*Measure Focus Spot
The focus spot analyzer can measure your laser beam power distribution and focal spot size of wavelengths from 266 – 1100nm. The average power can be from <1 to 400 Watts and the focal spot can be as small as 25µm. The FSA can also be used to measure how the focal spot shifts with power during its critical start-up phase.
-
product
Optical Camera Trigger
The Optical Camera Trigger is an optical sensor that detects pulsed light sources and generates outputs to trigger a camera. The front aperture of the Optical Trigger must be directed at a light source that provides the necessary properties for trigger activation. (e.g. a laser flash lamp, a pick-off source from the main laser beam, or similar). The light source may be a direct or indirect pulsed waveform.
-
product
Scanning Slit Beam Profiling
NanoScan
Measure your beam as never before with the NanoScan™ beam profiler. The advantage of scanning slit beam profiling is sub-micron precision for measuring beam position and size. Scan head configurations include Silicon, Germanium, and Pyroelectric versions for a wide range of wavelengths and laser power levels. The NanoScan software is available in two versions: Standard and Professional, and includes an extensive set of ISO quantitative measurements, an M2 Wizard, and the ability to measure laser power.
-
product
*OEM Power Sensors
The OEM “standard” sensors are actually families of existing OEM sensors with typical specifications shown. They can be tailored as needed to fit your specific requirements. In addition to the products described, Ophir has developed hundreds of other OEM solutions. These compact laser power sensors have built-in amplifiers and are easy to install. They contain all the electronics needed including algorithms to increase the sensor's speed of response. Connections to the sensors are simple, with the host providing DC power and the sensor providing a voltage or digital output. Outputs Available: DB15 smart sensor output; Calibrated analog output; RS232; USB; Ehthernet. Simply fill out the Sensor Customization form so we can provide just the right solution for your needs.
-
product
*Laser Pyroelectric Energy Sensors
Pyroelectric sensors for measuring repetitively pulsed energy at up to 25 kHz. These sensors use a pyroelectric crystal that generates an electric charge proportional to the heat absorbed. The response time of the pyroelectric sensor depends on the time it takes for the heat to enter the crystal and heat it up. For metallic type pyro detectors, this time is tens of μs and thus the metallic type can run at a high repetition rate. For the BF and BB type, the response time is milliseconds with a correspondingly lower repetition rate. Ophir pyroelectric detectors have unique and proprietary circuitry that allow them to measure long pulses as well as short pulses and work at a high duty cycle, i.e. where the pulse width is as much as 30% of the total cycle time.
-
product
Handheld Laser Power & Energy Meter
Vega 7Z01560
*Compatible with all standard Ophir Thermopile, BeamTrack, Pyroelectric and Photodiode sensors*Brilliant color large size TFT 320x240 display*Clear screen color for work with laser safety goggles*Illuminated keys for working in the dark*Both digital and analog needle display*USB and RS232 output to PC with Statistics package*Select between English and Japanese interfaces*Analog output*Soft keys and menu driven functions with on line help*Log every data point at up to 4000Hz with pyroelectric sensors*Non-volatile data storage up to 250,000 points*Laser tuning screen and power log*2 position kickstand*System Integrator Tools included: LabVIEW VIs, COM Object Interface
-
product
*High Power Measurement From Short Exposure
Ophir has a number of ways to measure high laser powers up to 12kW without heavy water cooled equipment. Most of today’s lasers can be set to emit for a short, precisely controlled period of time. If a short exposure to the laser of 0.3 – 10s is sufficient to measure the power then there are compact, uncooled sensors available for this purpose.