TSI Inc.
Produces precision measurement instruments for industries like environmental monitoring, healthcare, and manufacturing.
- 1-800-680-1220
+1 651-490-2860 - info@tsi.com
- 500 Cardigan Road
Shoreview, MN 55126
United States of America
Categories
-
product
Ventilator Test System
4070
The Certifier® FA Ventilator Test System 4070 is capable of testing multiple parameters of ventilator performance. It is designed to measure air, oxygen, and nitrous oxide flow and pressure in institutional, home care, field service, laboratory, and production applications. The Certifier FA ventilator test system is a battery-operated flow analyzer that can also test a variety of other medical equipment such as anesthesia gas delivery machines and oxygen concentrators.
-
product
Engine Exhaust Particle Sizer
3090
The Engine Exhaust Particle Sizer 3090 (EEPS™) spectrometer measures the size distribution of engine-exhaust particle emissions in the range from 5.6 to 560 nm with the fastest time resolution available. Users can visualize and study the dynamic behavior of particle emissions that occur during transient test cycles, during the first few seconds of a cold start, or during regeneration of a particle trap or diesel particulate filter (DPF).
-
product
Particle Deposition Systems
MSP’s 2300G3 Particle Deposition System sets the standards for wafer inspection and metrology equipment. This advanced tool is vital for increasing the yield of future leading-edge devices, while meeting the measurement needs of today.
-
product
Aerosol Neutralizer
3077A
The Aerosol Neutralizer model 3077A is a general-purpose radioactive neutralizer suitable for use with highly-charged and/or highly concentrated aerosols. The Model 3077A can be used with flows up to 5 L/min. If your flow rate will always be significantly higher than this, consider model 3012 and/or 3012A. If your particles will not be highly-charged and/or highly concentrated, consider model 3077.
-
product
Fume Hood Monitor
FHM10
Fume hoods are a primary source or protection in laboratories. Face velocity measurements are often used to gauge the performance of a fume hood’s ability to contain and exhaust hazardous chemicals. By accurately measuring face velocity and alarming on unsafe conditions, TSI’s FHM10 Fume Hood Monitors provide a high level of fume hood safety. And, the FHM10 helps users comply with standards and regulations set forth by OSHA, NFPA, ANSI Z9.5, and SEFA, calling for monitors to be installed on fume hoods.
-
product
Automated Filter Tester
3140-1
The model 3140 filter tester uses the same aerosol generation technology as the model 8130A respiratory filter tester. It works with Emery oil, DOP, DEHS, paraffin and other oils. Two new generation CPCs simultaneously count upstream and downstream particles. This enables accurate, repeatable and fast measurements, for example a HEPA filter can be tested in less than 15 seconds.
-
product
Alnor Micromanometer
AXD620
The Alnor® Micromanometer AXD620 is a rugged, compact, comprehensive micromanometer that measures pressure. It can be used with pitot tubes to measure velocity and then calculate flow rates with user–input duct size and shape. Premium features make it ideal for HVAC, environmental safeguards, commissioning, process control and system balancing.
-
product
Cascade Impactors
TSI’s suite of cascade impactors can collect particles with aerodynamic diameters (cutpoints) from 10 nm to 10 µm, in 3 to 13 different size fractions, and at flow rates of 2, 10, 30 or 100 L/min. The number of stages determines the size resolution of the collected samples, and consequently determines the level of detail of the data generated from the quantitative analysis of these collected samples.
-
product
VelociCalc Air Velocity Meter
9545-A
The VelociCalc® Air Velocity Meter 9545-A is like having multiple meters for the price of one. This meter simultaneously measures and data logs several ventilation parameters using a single probe with multiple sensors.
-
product
Advanced Aerosol Neutralizer
3088
Aerosol neutralization is an important component of aerosol science and engineering. Neutralizing aerosol particles can reduce electrostatic losses of particles within tubing or to other surfaces. Neutralization is also critical to gathering reliable particle size data when using a sizing instrument based on electrical mobility.
-
product
AEROTRAK™ Handheld Particle Counters
9306
The TSI AEROTRAK™ Handheld Particle Counters offer the most features and flexibility for customers interested in low cost and versatile particle contamination monitoring.
-
product
LDV System
PS-TM-1D-532
The PowerSight-based LDV System uses the latest solid-state laser technology to give you the powerful and compact laser module for LDV measurements. In addition to its power, the selected laser provides the excellent beam quality pertinent to the accuracy of LDV measurements.
-
product
Fast Mobility Particle Sizer
3091
The Fast Mobility Particle Sizer 3091 (FMPS™) spectrometer measures particles in the range from 5.6 to 560 nm, offering a total of 32 channels of resolution (16 channels per decade). It uses an electrical mobility measurement technique similar to that used in our SMPS. However, instead of a CPC, the FMPS spectrometer uses multiple, low-noise electrometers for particle detection
-
product
Certifier Flow Analyzers
TSI Certifier™ Gas Flow Analyzers are multi-functional pneumatic test systems capable of measuring flow, pressure, temperature, and oxygen concentration. They are ideal for testing ventilators, anesthesia workstations, and any other respiratory medical device that produces flows or pressures.
-
product
VELOCICALC Multi-Function Ventilation Meter
9565-A
The portable, handheld VELOCICALC® Multi-Function Ventilation Meter 9565-A features a menu-driven user interface for easy operation in your local language. On-screen prompts and step-by-step instructions guide the user through instrument setup, operation, and field calibration. The 9565-A also features an ergonomic, overmolded case design with probe holder and a keypad lockout to prevent tampering during unattended use. The 9565-A model includes the Articulated Probe 966 and is designed for use with a range of plug-in probes.