Ametek Scientific Instruments
AMETEK Scientific Instruments has been recognized as a global leader in the design and manufacture of instrumentation for scientific research, particularly in the field of electrochemistry and weak AC signal recovery.
- 801 S Illinois Avenue
Oak Ridge, TN 37830
United States of America
-
Product
Single Channel Potentiostats
12XX Series
-
The 12xx Series Potentiostats has two current models: the 1287A and 1280Z. This family of potentiostats communicate through trusted GPIB interface technology that can convert to USB for easy connection modern computers. The Solartron Analytical 1287A and 1280Z are often driven by CorrWare software for DC testing, such as Cyclic Voltammetry, and ZPLOT for AC testing, such as Electrochemical Impedance Spectroscopy.
-
Product
Scanning Droplet Cell
VS-SDC
-
Scanning Droplet System (SDC) uses a compact peristaltic pump to force electrolyte through a small diameter tube and into a specifically designed head. This PTFE-based SDC head is machined to allow electrolyte to flow past an installed Reference Electrode and then to a port at the base of the head.
-
Product
Scanning Electrochemical Microscope
VS-SECM (DC And AC)
-
The SECM integrates a positioning system, a bipotentiostat, and an ultramicroelectrode probe or tip. The positioning system moves the probe close to the surface of the sample, within the local imaging zone. The bipotentiostat can polarize the probe only (feedback mode) or the sample and the probe independently (generator-collector mode), while measuring the resulting current(s). The probe is specially designed to have a specific tapered polish (per the RG ratio) and active radius below 100 microns. The positioning system scans the probe and charts position with measured electrochemical parameters, creating a data map of local current.
-
Product
Single Channel Potentiostats
ModuLab XM ECS
-
ModuLab XM has modularity at the center of its design. Each system can be configured for electrochemical, materials, and photoelectrochemistry measurements. At the core of each of these is the Frequency Response Analyzer. The accuracy from design to calibration is at the heart of Solartron's success and reputation for impedance measurements.
-
Product
Single Channel Potentiostats
VersaSTAT Series
-
This family of instruments combines our option-based hardware and software platforms to create the most popular line of potentiostats. Introduced for the majority of researchers doing typical electrochemical experiments, this entire series gained a key improvement in 2018. As of August 1st, 2018, all VersaSTAT models have ± 2 Amp capability standard. Users can now study larger samples at faster rates.
-
Product
High Temperature Test System
129620A
-
Solartron Analytical, specialists in the design of precision impedance test equipment, has joined forces with high temperature Furnace specialists Carbolite, and sample holder specialists NorECS to produce a range of advanced high temperature materials characterization test systems.
-
Product
Scanning Kelvin Probe Microscope
VS-SKP
-
The Kelvin Probe experiment uses a nondestructive method to determine the relative work function difference between the probe and the sample. Work function describes the energy required to liberate an electron from the surface of a conductor; electrochemists often interpret this as the difference from an electrode’s Fermi Level, average energy of electrons, and that of vacuum.
-
Product
Non-contact Optical Surface Profiler
VS-OSP
-
The VersaSCAN OSP integrates the Base with a high-accuracy, high-speed laser displacement sensor. The OSP technique uses diffuse reflection mechanism to measure topography of a sample. OSP can be used to measure topography, as a very sensitive leveling mechanism, or charting topography to be implemented with other scanning probe techniques for constant-distance mode operation.
-
Product
Scanning Vibrating Electrode Technique
VS-SVET
-
The Scanning Vibrating Electrode Technique uses a single wire to measures voltage drop in solution. This voltage drop is a result of local current at the surface of a sample. Measuring this voltage in solution images the current at the sample surface. Current can be naturally occurring from a corrosion or biological process, or the current can be externally controlled using a galvanostat.
-
Product
Battery Analyzer
SI-9300R
-
Conventional cycler systems use PCs to transfer data from cycler channels to disk. SI-9300R instead uses advanced technology to write data direct to disk without PC intervention. For high channel count systems this dramatically reduces PC workload, increases system reliability and allows the PCs to concentrate on test control, channel monitoring and data analysis.
-
Product
Localized Electrochemical Impedance Spectroscopy
VS-LEIS
-
The VersaSTAT 3F applies an AC voltage to the sample emerged in electrolyte. This "global" voltage generates AC current to flow at the electrode / electrolyte interface. A dual-element probe is positioned in solution close to the surface of the sample. The electrometer measures a differential voltage measure between the two measurement elements as a measure of local voltage-drop in solution. This voltage-drop exists in solution because of current flow from local reactions at the sample, the resistance of the electrolyte and the spatial separation of the dual measurement elements.
-
Product
Single Channel Potentiostats
-
Potentiostats control a voltage and measure a resulting current. The Control Amplifier outputs power to the counter electrode (also called auxiliary electrode). A feedback loop is established to control the cell potential between the reference and working electrode. This voltage is measured by the input electrometer, that has a high impedance. This current is then measured between the working and counter electrodes while this potential is maintained at the working electrode and reference electrode.
-
Product
Impedance Analyzer
1260A
-
The model 1260A Impedance/Gain-Phase Analyzer is - without doubt - the most powerful, accurate and flexible Frequency Response Analyzer available today. In daily use by leading researchers wherever measurement integrity and experimental reliability are of paramount importance, the 1260A’s solid reputation is frequently endorsed in published research papers in fields.
-
Product
Multichannel Potentiostats
-
Multi Channel potentiostats/galvanostats from Princeton Applied Research and Solartron Analytical assist researchers increase their scope from the examination of a single sample at a time to multiple samples simultaneously. While providing the same level of accuracy as the single channel potentiostats, multi channel potentiostats can be configured to scale with your research today as well as provide solutions for the next step in your electrochemical research plan tomorrow.
-
Product
Battery Cycler
-
Rechargeable (secondary) batteries in real-world applications are charged and discharged many times until they reach end of life. Examples of this are batteries used in cell phones, PCs, power tools and automotive applications. After multiple charge/discharge cycles, cell performance starts to degrade. The batteries typically require charging more frequently until eventually they reach end of life and need to be replaced, with the original cells either being scrapped or repurposed.