Ametek Scientific Instruments
AMETEK Scientific Instruments has been recognized as a global leader in the design and manufacture of instrumentation for scientific research, particularly in the field of electrochemistry and weak AC signal recovery.
- 801 S Illinois Avenue
Oak Ridge, TN 37830
United States of America
-
product
Multichannel Potentiostats
Multi Channel potentiostats/galvanostats from Princeton Applied Research and Solartron Analytical assist researchers increase their scope from the examination of a single sample at a time to multiple samples simultaneously. While providing the same level of accuracy as the single channel potentiostats, multi channel potentiostats can be configured to scale with your research today as well as provide solutions for the next step in your electrochemical research plan tomorrow.
-
product
Potentiostat Galvanostat
VersaSTAT 3F
The VersaSTAT 3F shares similar specifications to the VersaSTAT 3 (10µs data acquisition) and the VersaSTAT 4 (4nA lower current range, enhanced filtering options) the VersaSTAT 3F was designed specifically to operate with other potentiostats or earth-grounded cells.
-
product
CellTest Multichannel Potentiostat
Simultaneous Electrochemical Impedance Spectroscopy (EIS) tests can be run on multiple cells by connecting Solartron 1455A/1451A series frequency response analyzer (FRA) modules to the 1470E. These FRAs can operate in single sine correlation or multi-sine / Fast Fourier Transform (FFT) analysis mode, providing the ultimate in speed, precision and accuracy. The 1455A FRA provides high performance impedance measurements over the frequency range 10 μHz to 1 MHz, while the 1451A FRA operates from 10 μHz to 100 kHz.
-
product
High Temperature Test System
129620A
Solartron Analytical, specialists in the design of precision impedance test equipment, has joined forces with high temperature Furnace specialists Carbolite, and sample holder specialists NorECS to produce a range of advanced high temperature materials characterization test systems.
-
product
Materials Test System
ModuLab XM MTS
I-V (voltage scans with current measurement - used to characterize electronic and dielectric materials)P-E (polarization / electric field - used to run hysteresis tests to characterize ferroelectric materials) High-speed pulse (used to activate charge carriers in electronic and dielectric materials)Staircase and smooth stepless analog ramp waveformsImpedance, admittance, permittivity / capacitance, electrical modulusC-V capacitance - voltage, Mott-SchottkyAutomatic sequencing of time domain and impedance/capacitance measurements
-
product
Single Channel Potentiostats
PARSTAT Series
The PARSTAT-series of potentiostats is defined by offering superior performance as standard. The PARSTAT4000A and PARSTAT3000A complement each other.Both of these single channel potentiostats operate in VersaStudio software with all techniques available, including Electrochemical Impedance Spectroscopy up to high frequency.
-
product
Scanning Kelvin Probe Microscope
VS-SKP
The Kelvin Probe experiment uses a nondestructive method to determine the relative work function difference between the probe and the sample. Work function describes the energy required to liberate an electron from the surface of a conductor; electrochemists often interpret this as the difference from an electrode’s Fermi Level, average energy of electrons, and that of vacuum.
-
product
Constant Distance SECM
VS-STYLUS
In collaboration with SENSàSION, we are pleased to offer the Soft Stylus Probe contact mode technique developed by Professor Hubert Girault and co-workers of the Laboratory of Physical and Analytical Electrochemistry (LEPA) at the École Polytechnique Fédérale de Lausanne (EPFL) for constant distance SECM. The probe technology offers the following benefits:
-
product
Potentiostat Galvanostat
EchemLab XM
EchemLab XM includes a reference grade potentiostat and frequency response analyzer (FRA). EchemLab XM has a built-in 100 V high voltage amplifier which can be used for not only for compliance measurements but also for high voltage cell polarization. This is useful in many high solution resistance applications, for example in organic electrochemistry. In addition to high voltage, power boosters can also be integrated to combine high current and high voltage in many specialized plating applications.
-
product
Frequency Response Analyzers
Frequency Response Analysis (also referred to as Transfer Function Analysis) measures the output spectrum of a system relative to a stimulus, and is used to characterize the dynamics of the system under test. The technique measures the magnitude and phase relationship between output and input waveforms as a function of frequency. The input signals may be from a wide range of sensors including acoustic (microphones/sonar), mechanical (accelerometers/displacement transducers), optical (photodetectors), and electrical (amplifiers).
-
product
Potentiostat Galvanostat
VersaSTAT 4
The improved low current performance with fA resolution and pA accuracy addresses current sensitive applications such as sensors, corrosion, inhibitors, and combined with the optional FRA, coating technologies. The additional analog filtering makes the VersaSTAT 4 an even better choice for low-current applications while the additional bandwidth filtering adds extra stability for capacitive cells. The VersaSTAT 4, with its additional capabilities, makes an exciting addition to our VersaSTAT family making them even more of an exceptional value for all of your application needs.
-
product
Potentiostat Galvanostat
PARSTAT 4000A
The PARSTAT 4000A stands alone in its ability to deliver high compliance voltage and wide dynamic current range, as standard, to cover a range of applications. The PARSTAT 4000A builds on PAR's history as the world-leader in DC electrochemical measurements and takes advantage of a common R/D team with Solartron Analytical, the world-leader in Frequency Response Analyzer (FRA) technology, to provide a best-in-class complete system.
-
product
Battery Cycler
Rechargeable (secondary) batteries in real-world applications are charged and discharged many times until they reach end of life. Examples of this are batteries used in cell phones, PCs, power tools and automotive applications. After multiple charge/discharge cycles, cell performance starts to degrade. The batteries typically require charging more frequently until eventually they reach end of life and need to be replaced, with the original cells either being scrapped or repurposed.
-
product
Localized Electrochemical Impedance Spectroscopy
VS-LEIS
The VersaSTAT 3F applies an AC voltage to the sample emerged in electrolyte. This "global" voltage generates AC current to flow at the electrode / electrolyte interface. A dual-element probe is positioned in solution close to the surface of the sample. The electrometer measures a differential voltage measure between the two measurement elements as a measure of local voltage-drop in solution. This voltage-drop exists in solution because of current flow from local reactions at the sample, the resistance of the electrolyte and the spatial separation of the dual measurement elements.
-
product
Room Temperature Sample Holders
12962A
The 12962A sample holder is designed to allow accurate impedance tests of solid materials to be performed at room temperature. The sample holder consists of two parallel electrodes, one of which is fixed in position and the other which can be moved into contact with the sample by adjustment of a micrometer. The sample holder makes use of guard ring and reference techniques in order to improve accuracy by reducing “fringing” effects at the edge of the sample. The standard electrode provided is 20mm diameter.