Picoprobe
Line of microwave and oscilloscope probes, has served the on-wafer probing needs of the worldwide semiconductor industry, beginning with a line of high impedance troubleshooting probes for diagnostic studies of the internal workings of complex logic and memory chips.
- (239) 643-4400
- 239 643-4403
- email@ggb.com
- 4196 Corporate Sq
Naples, Fl 34104
United States of America
-
Product
High Impedance Active Probes
35
-
The Picoprobe Model 35 has been engineered to meet the stringent demands of advanced high frequency circuit designers.
-
Product
Solid Tungsten Probe Tips
ST Series
-
The ST SERIESof probe tips, available from GGB Industries, Inc., are precision crafted from a 0.020 inch (0.51mm) diameter solid tungsten shaft that is electrochemically sharpened to a specified point. These durable, 1.5 inch long solid tungsten shaft probe tips are for use in most standard micropositioners when probing an integrated circuit, pad, or line. A variety of radius point sizes from 0.5 microns to 10 microns are available to accommodate any probing need.
-
Product
Microwave Testing
110H
-
The PICOPROBE® MODEL 110H is a high performance microwave probe which incorporates our patented coaxial design techniques and has inherent low loss and low dispersion characteristics.
-
Product
High Impedance Active Probes
18C & 19C
-
High impedance probes, PICOPROBE® MODEL 18C and MODEL 19C, combine the most advanced MOS and bipolar technologies with special, low capacitance packaging techniques to achieve truly remarkable electronic measurement capabilities. While being manufactured each instrument is individually optimized for the best possible performance. The extremely low input capacitance, high input impedance, and almost negligible input leakage current permits the direct probing of even the most sensitive MOS dynamic nodes. At the same time, the full dc capability of this Picoprobe coupled with the high speed capability permits the full characterization of circuits.
-
Product
Microwave Testing
75
-
The MODEL 75 PICOPROBE® sets new standards in microwave probing performance. Benefiting from coaxial techniques, which have inherent low loss and low dispersion characteristics, the Model 75 Picoprobe, with or without the bias T option, achieves an insertion loss of less than 1.0 db (typical) and a return loss of greater than 15 db (max.) over its frequency range.
-
Product
High Impedance Active Probes
28 AND 29
-
Designed to serve the needs of integrated circuit engineers working in the most advanced high speed, submicron, MOS technology. These high frequency instruments include the attractive features of the Models 18C and 19 including full dc capability, negligible dc current drain, and extremely low input capacitance. In addition the frequency range of the Models 28 and 29 has been extended to a full 1 GHz.
-
Product
High Impedance Active Probes
34A
-
Engineered to meet the stringent demands of advanced high frequency circuit designers. This high impedance probe combines full DC capability, rise/fall times of 120 ps, and a nominal loading input impedance of 10 megohm shunted by 0.1 pf. Signal attenuation is 20:1 with a 50 ohm oscilloscope input.
-
Product
High Impedance Active Probes
7A
-
An unterminated version, can be used for capacitance and resistance measurements or in low to medium speed signal applications where a 50 ohm termination is not required. A flexible coaxial cable length of 6 feet in length is standard on the Model 7A; however, when used for capacitance measurements, GGB Industries, Inc., recommends using a shorter 3 foot cable. If a shorter length of cable is desired for capacitance measurements, please specify it when ordering (Model 7A-3ft.). Please note that Model 7A uses Model 7 replacement tips.
-
Product
Multi-Contact Wedge
-
The GGB Industries MULTI-CONTACT WEDGE allows for more chip design flexibility because it is custom configured to your circuit. Four Wedges can be used at the same time to probe a complete chip.
-
Product
Microwave Testing
325B
-
The Model 325B Picoprobe sets new® standards in microwave probing performance. Benefiting from coaxial techniques, which have inherent low loss and low dispersion characteristics, the Model 325B Picoprobe achieves an insertion loss of less than 3.0 db and a return loss of greater than 15 db over its frequency range (see accompanying data).
-
Product
High Impedance Active Probes
12C
-
A high speed, high input impedance active probe for measuring the internal node voltage of integrated circuits. The input is 1 megohm shunted by 0.1 pf and the rise/fall times are 0.8 ns. This instrument has full dc capability and can be used with any oscilloscope. The Model 12C was specially designed so that when used in conjunction with a high input impedance oscilloscope, signal attenuation is 10:1 and with a 50 Ohm input, signal attenuation is 20:1.
-
Product
Calibration Substrates
-
The GGB Industries, Inc., line of CALIBRATION SUBSTRATES allows the user to calibrate any GGB Industries, Inc., microwave Picoprobe® at the probe tip. The underlying principal of the calibration of a measurement system is to provide accurate known standards to which the measurement system can be connected
-
Product
Microwave Testing
170
-
The PICOPROBE® MODEL 170, a high performance microwave probe which incorporates a WR-6 waveguide with our patented coaxial design techniques, has inherent low loss and low dispersion characteristics.
-
Product
Dual Microwave Probe
-
The PICOPROBE® DUAL MICROWAVE PROBE consists of two separate probes mounted on a single holder. One probe is fixed to the holder; the other is adjustable. Each probe may be individually configured with GSG, GS, or SG footprints having any fixed pitch from 50 to 2540 microns. The probe to probe (signal to signal) spacing is user adjustable over a 4000 micron (160 mil) range. When ordering, an initial signal to signal spacing should be specified (up to .75 inches).
-
Product
Microwave Testing
50
-
The MODEL 50 PICOPROBE® sets new standards in microwave probing performance. Benefiting from coaxial techniques, which have inherent low loss and low dispersion characteristics, the Model 50 Picoprobe®, with or without the bias T option, achieves an insertion loss of less than 0.8 db (typical) and a return loss of greater than 15 db (max.) over its frequency range.